The TCP3500/4000 Series is a universal 3-phase AC-DC converter with adjustable DC output and universal 3-phase AC input. Conduction cooling (no fan) makes this power supply series suitable for a wide variety of Industrial Applications that can utilize conduction or liquid cooling, negating the use of fans. Emphasis is given on reliability and long life. Parallel operation is possible up to 16 units (57.6 kW). The PSU includes DSP which enables monitoring of electrical parameters (including input voltage of all 3 phases) and controlling the PSU from system controller. An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller. World-Wide 3-phase Input Voltage Range (nom. 115 - 277 V / 200 - 480 V) Power Factor > 0.94 3 High Power Density 16 W/in 94% Typical Efficiency Parallel Operation up to 16 Units (up to 57.6 kW) Cold-Plate Cooling System 0 to 50C of Cold-Plate Surface, 0 to 70C of Ambient Air Temperature Possibility to Install 4 Units in 2U 19 Rack Advanced Performance for Fast Dynamic and Pulsed Load up to 100 kHz (Optional) RS485 Interfaces Wide Adjustable Output Voltage Range Fast Output Voltage Set Response (5 ms) Active Current Sharing SEMI F47 Compliant 2 TCP3500/4000 Series NOMINAL OUTPUT MAX INPUT VOLTAGE MAX OUTPUT MODEL OUTPUT VOLTAGE OUTPUT AVAILABILITY RANGE CURRENT VOLTAGE RANGE POWER 180 528 Vrms, Adjustable TCP3500-1024G 28 V 125 ADC 3500 W Mass production 50/60 Hz 10 32 VDC 180 528 Vrms, Adjustable 1 TCP3500-H048G 48 V 73 ADC or pulse 3500 W Mass production 50/60 Hz 10 50 VDC 180 528 Vrms, Adjustable TCP3500-1048G 48 V 73 ADC 3500 W Mass production 50/60 Hz 10 50 VDC 180 528 Vrms, Adjustable 45 ADC or 39 A 2 TCP4000-H090 90 V 3500 / 4000 W Mass production 1 50/60 Hz 30 100 VDC pulse 1 PSU model with pulse load operation capability 0 100 kHz, 0 100% Duty, 0 A/Iout max. 2 Output Power 4000W at Input Voltage range 340 528 Vrms (L-L) PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT 3-phase (L-N / L-L), 3 wires + PE 115 - 277 / 200 - 480 V Input Voltage Permitted variation (L-N / L-L) 104 - 305 / 180 - 528 V Hz 50/60 Input Frequency Permitted variation 47 63 Hz Input Current per Line at 3 x 180 V (line to line) 14 Arms Input Current THDi Typical 30 % Power Factor Load above 40% 94 Fuse 3 x 20 A, Fast acting PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Output Voltage Adjustable or fixed (see Model Selection table) Output Power Rating 3500 W Output Current Fixed or Adjustable (60 100%) Efficiency Input Voltage 400 Vrms (L-L) and load above 40% 94 % 0.5 % Voltage Setting Accuracy Line Regulation Io = 0.5 * Io nom 0.5 % Load Regulation 0.3 % Thermal Drift 0.02 %/C load variation 10-100% and back: 5 % Recovery time: 2 ms Transient Response load variation 50-100% and back: 3 % Recovery time: 0.4 ms Ripple Vout nom (BW 20 MHz) 1.5 % Output Start Up 2 s Rise Time 250 ms tech.support psbel.com