These dials are currently available Features but not recommended for new 27 mm and 28 mm diameter designs. 10 turns No backlash - mounted directly to potentiometer shaft For use with precision High force, positive brake potentiometers or other rotating RoHS compliant* devices up to 10 turns CT-23/CT-26 Turns-Counting Dial Mechanical and Physical Characteristics Number of Turns .............................................................................................................................................................................0 to 10 Readability - Over 10 Turns .................................................................................................................................... Within 1/500 of a turn Torque with Brake Engaged ................................................................................................................ 9.88 N-cm (14.0 oz.-in.) maximum Markings ........................................................................................................................................................White on black background Locking Brake ...........................................................................................................................................................Yes, Positive, friction Weight ........................................................................................................................................................................... 34 grams (1.2 oz.) Set Screw ...................................................................................................................................................... ISO M3x 0.35, one included Set Screw Tightening Torque .............................................................................................................. 16.94 N-cm (1.5 lbs.-in.) minimum Hex Key Size ........................................................................................................................................................................... 1.5 mm hex Shaft and Bushing Requirements Shaft Diameter Requirements ................................................................................................................................... Refer to chart below Shaft Extension Beyond Face of Locator Plate .......................................................................................... 11.05 mm (0.43 in.) minimum 16.25 mm (0.63 in.) maximum Bushing Extension Beyond Face of Locator Plate ...................................................................................... 4.00 mm (0.15 in.) maximum Bourns Model CT-23, front of panel mounting, digital turns- Bourns Model CT-26 recessed mounting digital turns-counting dial, counting dial saves valuable internal space. Highly accurate, it will counterpart to the Bourns Model CT-23, provides a lower panel pro- enhance the man/machine interface of any control panel. Easy to le. The design simpli es installation requiring only one panel hole. read white on black numerals provide excellent legibility and The CT-26 maintains the same high level of symmetry, accurate readings within 1/500 of a turn. legibility and accuracy of its counterpart. CT-23 MOUNTING INSTRUCTIONS CT-26 MOUNTING INSTRUCTIONS 1. Drill or punch panel. See suggested hole pattern below. 1. Drill or punch panel. See suggested hole pattern below. 2. Insert potentiometer in panel. 2. Insert turns-counting dial in panel cutout and secure with 3. Mount potentiometer in panel with nut and lockwasher supplied mounting nut. with the potentiometer. 3. Secure locator plate to potentiometer bushing using two hex 4. Turn the potentiometer shaft counterclockwise to obtain nuts. minimum resistance or voltage ratio (not necessarily at the end 4. Turn the potentiometer shaft counterclockwise to obtain of travel). minimum resistance or voltage ratio (not necessarily at the end 5. Loosen set screw in knob with allen wrench. Set the dial readout of travel). to 000. 5. Loosen set screw in turns-counting dial with allen wrench. Set 6. Slip the dial carefully over the potentiometer shaft. Tighten the the dial readout to 000. set screw without causing movement of the dial readout or 6. Slip the potentiometer shaft into the turns-counting dial, insuring potentiometer shaft. that the notch in the locator plate is over the pin at the rear of the dial. Tighten the set screw without causing movement of the dial readout or potentiometer shaft. For mounting, the maximum recommended panel thickness is 1/8 (3.1 mm). MM DIMENSIONS: (INCHES) Dimensional Drawings How To Order Part Accepts Shaft Number Diameter Finish CT-23-6A 6.35 mm (.250) Black CT-23-6M 6 mm (.236) Knurl with CT-26-6A 6.35 mm (.250) Satin CT-26-6M 6 mm (.236) Chrome Face REV. 01/15 *RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Speci cations are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their speci c applications. *RoHS COMPLIANT