AFBR-S10PS010Z and AFBR-S10PS011Z Point Sensor for Light Detection and Plastic Optical Fiber Connector for Point Sensor Data Sheet Description Features AFBR-S10PS010Z is an optical point sensor with Light capturing through the translucent head of the point self-supervision functionality. The light that meets the point sensor sensor is captured and fed into a plastic optical fiber (POF). The Light coupling into a plastic optical fiber by means of the self-supervision functionality is achieved by an in-built plastic optical fiber connector coupling between two fibers. AFBR-S10PS011Z is a miniature Optical link self-supervision supported (heartbeat signal) connector used to connect a duplex POF cable to the point Low Halogen and RoHS compliance sensor. The special POF-based sensor design allows the system UL flammability UL94HB engineer to avoid any galvanic contact between the arc flash Good chemical resistance area and the detection electronics. Operating temperature range 40C to 85C Both AFBR-S10PS010Z and AFBR-S10PS011Z are part of the Acceptance cone exceeds 180 spherical with high Broadcoms comprehensive arc flash detection portfolio. In homogeneity combination with Broadcoms sensor transceiver Suitable for 1.0/2.2-mm diameter duplex plastic optical AFBR-S10TR001Z, they are intended to be used for the fiber (POF) detection of arc flash events in electrical power grids. Applications Arc flash event detection Light detection Broadcom - 1 -AFBR-S10PS010Z and AFBR-S10PS011Z Data Sheet Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause catastrophic damage to the device. Limits apply to each parameter in isolation, all other parameters having values within the recommended operation conditions. It should not be assumed that limiting values of more than one parameter can be applied to the products at the same time. Exposure to the absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Symbol Min. Max. Unit Notes a Storage Temperature T 40 +85 C S a Installation Temperature T 0+40 C i a. Storage and operating temperatures refer to the ranges over which the connectors can be used when not subjected to mechanical stress. Installation temperature refers to the ranges over which connectors may be installed onto the fiber and over which connectors can be connected and disconnected from the transceiver. Recommended Operating Conditions Parameter Symbol Min. Max. Unit Notes Operating Temperature T -40 +85 C O Mechanical Characteristics Parameter Min. Typ. Max. Unit Note a Retention force, connector to point sensor 14 N a Insertion force, connector to point sensor 15 N a Tensile force, connector to cable 35 N b Screw tightening torque 0.7 Nm a. Typical data is at 25C. b. Values applicable when an M3 screw and an M3 washer are used. Optical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes 8 8 2a, b Capturing Constant Cp 1.1 10 1.8 10 m c Insertion Loss aT 13 20 dB a. Valuesmeasured with 10 m of POF duplex cable (1.0-mm core diameter, 2.2-mm jacket diameter, NA 0.5). b. Cp definition: The capturing properties of a point sensor are characterized by Cp, calledCapturing Constan of the point sensor, which is defined as follows: The optical power P at the photo detector can be calculated as P = Cp E / K P: Optical power on photo detector (W). 2 Cp: Capturing constant (m ) 2 E: Optical power density in illuminated area (W / m ), halogen lamp used as a light source. (A L2 / 10) K: Correction factor for transmission losses, calculated as: K = 10 . A: Fiber transmission loss 0.34 dB/m. L2: Length of fiber between illuminated area and photo detector (m). c. For heartbeat signal at 650 nm coupled from one fiber to the other fiber in a duplex cable. Broadcom - 2 -