DATA SHEET LightPulse LPe12004 8Gb Fibre Channel PCIe 2.0 Host Bus Adapter Unparalleled Manageability, Reliability, Performance and Ease of Deployment Streamlined installation and management, unrivaled scalability, and industry-leading Key Benefits virtualization support make the quad-port Emulex LightPulse LPe12004 Fibre n Provides superior performance for the enterprise Channel host bus adapters (HBA) ideal solutions for enterprise, mixed-OS and virtual n Integrates seamlessly into existing SANs server environments. n Delivers quad-port connectivity for 8GFC target applications Proven Design, Architecture and Interface n Provides Fibre Channel connectivity for slot Emulex LightPulse HBAs highly integrated processor design minimized onboard constrained server environments components to improve host performance and ecffi iency. Advanced error-checking n Supports IT server consolidation and energy features ensure the integrity of block data as it traverses the SAN. Emulexs firmware- conservation initiatives based architecture enables feature and performance upgrades without costly n Allows application of SAN best practices, tools hardware changes. The unique Service Level Interface (SLI) allows use of a common and processes with virtual server deployments driver across all models of Emulex HBAs on a given OS platform. Installation and n Assures data availability and data integrity management facilities are designed to minimize server reboots and further simplify n Improves IT staff productivity through simplified deployment. deployment and management Powerful Management Software for Maximum Data Center Ecffi iency Key Features The Emulex OneCommand Manager enterprise class management application n Support for Message Signaled Interrupts features a multiprotocol, cross-platform architecture that provides centralized eXtended (MSI-X), improves host utilization management of all adapters provided by Emulex. This enables IT administrators to and enhances application performance manage network connectivity with one tool for maximum ecffi iency. OneCommand n Support for 8GFC, 4GFC and 2GFC devices Manager also features: n Comprehensive virtualization capabilities with n OneCommand Manager plug-in for VMware vCenter Serverenables support for N Port ID Virtualization (NPIV) and comprehensive control of Fibre Channel HBAs and network (FCoE, iSCSI and Virtual Fabric TCP/IP NIC) connectivity solutions provided by Emulex from VMwares vCenter n Host to Fabric FC-SP authentication Server management console. Emulex OneCommand Manager plug-in for VMware n Long wave optical transceiver model available vCenter Server supports both the new VMware vSphere 5.1 Web Client and the allows the board to transmit signal over long VMware vCenter Server desktop client with an identical feature set regardless of distances the client. n Secure management with role-based administration integrated with Light Directory Access Protocol (LDAP) and Active Directory (AD) services n BlockGuard readyensures end-to-end data integrity n Common driver model allows a single driver to support all Emulex HBAs on a given OS n Easy deployment of new firmware with minimal server reboots n Efficient centralized administration of Emulex HBAs via powerful management tools n PCIe 2.0 bus compliant, with PCIe 1.0 backward compatibility supported SPECIFICATIONS LightPulse LPe12004 8Gb Fibre Channel PCIe 2.0 Host Bus Adapter Standards Agency Approvals Management Features ANSI Fibre Channel: FC-PI-4, FC-FS-2, FC-FS-2/AM1, North America: The Emulex OneCommand Manager application FC-LS, FC-AL-2, FC-GS-6, FC-FLA, FC-PLDA, FC-TAPE, - FCC Class A enables centralized discovery, monitoring, reporting, FC-DA, FCP through FCP-4, SBC-3, FC-SP, FC-HBA and - UL/CSA Recognized and administration of Emulex HBAs and UCNAs SMI-S v1.1 Europe: on local and remote hosts. Powerful automation PCI Express base spec 2.0 - CE Mark capabilities facilitate remote driver parameter, PCI Express card electromechanical spec 2.0 - EU RoHS compliant firmware and boot code upgrades. Advanced Fibre Channel class 2 and 3 - TUV Bauart Certified diagnostic features such as adapter port beaconing PHP hot plug-hot swap Japan: and adapter statistics help to optimize management - VCCI Class A and network performance while the environmental Architecture Taiwan: monitoring feature helps to maintain optimum - BSMI Class A host to fabric connections. In addition to the GUI Quad-port Korea: interface, management functions can also be 8GFC, 4GFC or 2GFC Link speeds automatically - MSIP (formally KCC/MIC) Class A performed via a scriptable Command Line Interface detected China: (CLI) as well as a web browser. With in-band and out- Integrated data buffer and code space memory - China RoHS Compliant of-band management capabilities, Emulex provides data center administrators with the greatest level of Comprehensive OS Support (Please refer to the product page on management flexibility. Windows, Linux, NetWare, Solaris (except DR), www.emulex.com for further details) OneCommand Manager supports role-based VMware management to facilitate administration of adapters Additional support is available from OEMs Ordering Information throughout the data center without compromising and partners security. Management privileges can be assigned LPe12004-M8 based on LDAP and AD group memberships. - Quad-port, multi-mode optic interface Hardware Environments Emulexs management instrumentation complies to Open Management Standards, such as SMI-S and PowerPC, SPARC, x86, x64 and Additional Features common HBA API support, which enables seamless Intel Itanium 64-bit processor family Performance features upward integration into enterprise storage and Doubling the maximum Fibre Channel link rate server management solutions. Optical from 4GFC to 8GFC and enhanced virtualization Data rates: 2.125, 4.25 and 8.5GFC capabilities help support IT Green initiatives (auto-detected) Frame-level Multiplexing and out-of-order frame Optics: Short wave lasers with LC type connector reassembly increases link efficiency and maximizes Cable: Operating at 8Gb/s HBA performance. - 50/125m (500MHz*km BW)-up to 50m Data protection features - 50/125m (2000MHz*km BW)-up to 150m End-to-end data protection with hardware parity, CRC, ECC and other advanced error checking and Physical Dimensions correcting algorithms ensure data is safe from PCI full-height, half-length form factor card corruption. 111.15mm x 167.64mm (4.376 x 6.600) Deployment and management features Standard bracket Universal Boot capability allows the appropriate boot environment to be automatically selected for any Power & Environmental Requirements given hardware. Volts: +3.3, +12 Boot from SAN capability reduces system Operating temperature: 0 to 55 C (32 to 131 F) management costs and increases uptime. Storage temperature: -40 to 70 C (-40 to 158 F) Detailed real-time event logging and tracing enables Relative humidity: 5% to 95% non-condensing, quick diagnosis of SAN problems. 23 C wet bulb Beaconing feature flashes the HBA LEDs, simplifying their identification within server racks. Environmental monitoring feature helps to optimize SAN availability. World Headquarters 3333 Susan Street, Costa Mesa, CA 92626 +1 714 662 5600 www.emulex.com Bangalore, India +91 80 40156789 Beijing, China +86 10 84400221 Dublin, Ireland+35 3 (0) 1 652 1700 Munich, Germany +49 (0) 89 97007 177 Paris, France +33 (0) 158 580 022 Tokyo, Japan +81 3 5325 3261 Wokingham, United Kingdom +44 (0) 118 977 2929 2013 Emulex, Inc. All rights reserved. This document refers to various companies and products by their trade names. In most, if not all cases, their respective companies claim these designations as trademarks or registered trademarks. This information is provided for reference only. Although this information is believed to be accurate and reliable at the time of publication, Emulex assumes no responsibility for errors or omissions. Emulex reserves the right to make changes or corrections without notice. This report is the property of Emulex and may not be duplicated without permission from the Company. 13-1202-revC 6/13