D-SD-Series eries CIRCUIT BREAKER Designed for snap-on-back panel rail mounting on either a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din Rail, allowing rapid and simple mounting and removal of the breaker. It features recessed, wire-ready, touch-proof, shock-resistant terminals, suitable for automatic screwdriver assembly, as well as Dead Front construction characteristics. Available with a Visi-Rocker two-color actuator, which can be specified to indicate either the ON or the TRIPPED/OFF mode, or solid color rocker or handle type actuators. All actuator types fit in the same industry standard panel cutouts. Product Highlights: Typical Applications: 0.02 - 50 Amps Industrial Controls 480 VAC or 65 VDC Renewable Energy 1-4 poles (Handle) 1-3 poles (Rocker) Choice of Time Delays DIN rail mounting Precise temperature independent operation Wiping contacts mechanical linkage with two-step Finger safe terminals Common trip linkage between poles ensures that an overload in one pole will trip all adjacent poles Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales carlingtech.com www.carlingtech.com Application Support: team2 carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 D-Series Circuit Breaker - General Specifications 2 Mechanical Electrical Maximum Voltage AC, 480 wye/277 VAC Endurance 10,000 ON-OFF operations 6 (See Table A), 50/60 Hz, 65VDC per minute with rated Current Standard Current Coils 0.100, 0.250, 0.500, 0.750, 1.00, and Voltage. 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, Trip Free All D-Series Circuit Breakers will 25.0, 30.0, 35.0, 40.0 & 50.0. trip on overload, even when Other ratings available - actuator is forcibly held in the ON consult factory. position. Standard Voltage Coils DC - 6V, 12V AC - 120V, other Trip Indication The operating actuator moves ratings available, see ordering positively to the OFF position scheme. when an overload causes the Insulation Resistance Minimum of 100 Megohms at 500 breaker to trip. VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one Physical minute between all electrically Number of Poles Rocker Type: 1-3 Handle Type: isolated terminals. D-Series circuit 1-4 breakers comply with the 8mm Internal Circuit Config. Switch Only and Series Trip with spacing and 3750V 50/60 Hz current or voltage trip coils. dielectric requirements from Weight Approximately 128 grams/pole hazardous voltage to operator (Approximately 4.57 ounces/pole) accessible surfaces and between Standard Colors Housing - Black Actuator - See adjacent poles per Publications Ordering Scheme. EN 60950 and VDE 0805. Mounting Mounts on a standard 35mm Resistance, Impedance Values from Line to Load Terminal Symmetrical DIN Rail (35 x 7.5 or - based on Series Trip Circuit 35 x 15mm per DIN EN5002). Breaker RESISTANCE PER POLE VALUES Environmental from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: CURRENT TOLERANCE (AMPS) (%) Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per 0.10 - 5.0 15 Method 213, Test Condition I. 5.1 - 20.0 25 Instantaneous and ultra-short 20.1 - 50.0 35 curves tested 90% of rated current. Vibration Withstands 0.060 excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultra-short curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour Pulse Tolerance Curves cycles + 25C to +65C, 80- 98% RH. Salt Spray Method 101, Condition A (90-95% RH 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles -55C to +25C to +85C to +25C). Operating Temperature -40 C to +85 C *Manufacturer reserves the right to change product specification without prior notice. Email: sales carlingtech.com Application Support: team2 carlingtech.com Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com