H-SH-Series eries CIRCUIT BREAKER The H-Series hydraulic-magnetic circuit breaker provides maximum and dependable circuit protection, while providing a cost effective, compact solution. By meeting the IEC spacing requirements, the H-Series is the ideal choice for international market applications. It also features a trip-free mechanism, which will open the contacts when a fault condition occurs, even if the handle is held in the ON position. 1-3 poles 1-35 amps 65VDC, 80VDC, 250VAC UL recognized, CSA accepted, TUV & CCC certified. Resources: Configure a Complete Part Download CAD & Sales Drawing Product Highlights: Typical Applications: Choice of actuator styles Telecom / Datacom UL1077, CCC, CSA, C22.2 and EN60934 approvals Marine Compact size Temperature stable operation -40 C to +80 C Choice of terminals, including PCB Single or multi-pole configurations Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales carlingtech.com www.carlingtech.com Application Support: team2 carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 H-Series Circuit Breaker General Specifications 2 Electrical Tables Table A: Lists UL Recognized, CSA Accepted and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. H-SERIES: COMPONENT SUPPLEMENTARY PROTECTORS Voltage Current Rating Short Circuit Capacity (Amps) Application Codes Circuit Minimum UL CSA TUV Max Full Load Configuration Poles Frequency Phase Without Without (Icn) Without Rating Amps UL CSA Backup Fuse Backup Fuse Backup Fuse 65 DC --- 1 - 25 1 3000 3000 3000 TC1, OL1, U1 TC1, OL1, U1 65 DC --- 26 - 35 1 3000 3000 3000 TC1, OL1, U3 TC1, OL1, U3 80 DC --- 1 - 25 1 1000 1000 1000 TC1, OL1, U1 TC1, OL1, U1 1 80 DC --- 26 - 35 1 1000 1000 1000 TC1, OL1, U3 TC1, OL1, U3 Series 250 50 / 60 1 1 - 35 1 1500 1500 500 TC1, OL1, U1 TC1, OL1, U3 250 50 / 60 1 1 - 35 2 1500 1500 500 TC1, OL1, U3 TC1, OL1, U3 250 50 / 60 3 1 - 35 3 1500 1500 500 TC1, OL0, U3 TC1, OL0, U3 Notes: 1 Polarity Sensitive Electrical Typical Protector Resistance Maximum Voltage 250VAC 50/60Hz 80 VDC DCR and Impedance values are based on measurements Current Ratings Standard current coils: 1.00, 2.50, by the voltmeter ammeter method. Rated current is applied 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, for one hour at a voltage not less than 20 volts. Ambient 30.0, 32.0, 35.0 temperature: 25 Tolerance: Below 10 amps +/- 25% SPDT: 10.1A-250VAC, Above 10 amps +/-35% Auxiliary Switch Rating 1.0A-65VDC/0.5A-80VDC, 0.1A-125VAC (with gold contacts) Impedance Chart Mechanical Series Current Rating (Amps) Endurance 10,000 ON-OFF operations 6 DC-Ohms 50/60Hz-Ohms per minute with rated current & 1 0.85 0.87 voltage 2.5 0.13 0.15 5 0.035 0.036 Physical 7.5 0.018 0.019 10 0.010 0.011 Number of Poles 1-3 15 0.006 0.0061 Weight Approx. 48 grams/pole (1.7 oz) 20 0.005 0.0051 Internal Circuit Config. Series and Switch Only (with or 25 0.003 0.0035 without auxiliary switch) 30 0.0025 0.0026 35 0.0021 0.0022 Agency Approvals UL Recognized under the Component Recognition Program as Protectors, Supplementary (Guide QVNU2 File E75596) UL standard 1077 CCC certified, Certificate No. 2010010307447291 CSA Accepted Supplementary Protector CSA standard C22.2 No. 235 TUV certified to EN60934, Certificate No. R50204086 *Manufacturer reserves the right to change product specification without prior notice. Email: sales carlingtech.com Application Support: team2 carlingtech.com Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com