NOW PART OF M-Series Hydraulic-Magnetic Circuit Breaker PRODUCT WEBPAGE request sample, configure part Miniature Circuit Breaker The M-Series hydraulic-magnetic circuit breakers offer high performance in a compact, front panel mount design. Multiple agency approvals and options for terminals, panel hardware and actuator styles allow for extensive design flexibility. Wiping contacts assure longevity. These miniature circuit breakers are available as a one to two or parallel pole configuration, rated from 0.02 to 50 amps, up to 250VAC/80VDC with a max IC of 1,000 amps 600 amps TUV and 500 amps VDE. 1-2 0.2-50 125/250 80 Poles Amps VAC Max VDC Max Typical Applications Telecom Marine Power Supplies Transportation Generators Medical Equipment www.carlingtech.com 860.793.9281 sales carlingtech.comTech Specs Mechanical Electrical Endurance 10,000 ON-OFF operations 6 per Maximum Voltage 125/250 VAC 50/60 Hz, 80 VDC minute with rated Current and (See Rating Tables.) Voltage. Current Ratings Standard current coils: 0.100, Trip Free All M-Series Circuit Breakers will 0.250, 0.500, 0.750, 1.00 thru 15.0 in trip on overload, even when 1 amp increments, 18.0, 20.0, 25.0, actuator is forcibly held in the ON 30.0. Other ratings available position. - see Ordering Scheme. Trip Indication The actuator moves positively to Standard Voltage Coils DC - 6V, 12V AC - 120V,other the OFF position when an ratings available, see ordering overload causes the circuit scheme. breaker to trip. Auxiliary Switch Rating SPDT 7A 250VAC, 7A (Res) 28VDC, 4A (Ind.) 28VDC, 0.25A Physical 80VDC (Res) (silver contacts), 0.1A 125VAC (gold contacts). Number of Poles 1 or 2 Insulation Resistance Minimum of 100 Megohms at 500 Internal Circuit Config. Series with or without VDC. Auxiliary Switch. Switch Only with or without Dielectric Strength UL, CSA 1500V, 50/60 Hz for one Auxiliary Switch. minute between all electrically isolated terminals. M-Series Weight Approximately 30 grams/pole Circuit Breakers comply with the (Approximately 1.07 ounces/pole) 8mm spacing and 3750 V 50/60Hz dielectric requirements Standard Colors See Ordering Scheme from hazardous voltage to operator accessible surfaces, per Environmental Publications IEC 380, 435, 950, EN 60950 and VDE 0805. Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Shock Withstands 100 Gs, 6ms, sawtooth Breaker. while carrying rated current per Method 213, Cond. I.Instantaneous curves tested at 80% of rated RESISTANCE PER POLE VALUES from Line to Load Terminals current. (Values Based on Series Trip Circuit Breaker) Vibration Withstands 0.060 excursion CURRENT TOLERANCE from 10-55 Hz, and 10 Gs 55-500 (AMPS) (%) Hz, at rated current per Method 204C, Test Condition A. 0.10 - 20.0 25 Instantaneous curves tested at 20.1 - 50.0 35 80% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles + 25C to +65C, 80- 98% RH. Salt Spray Method 101, Condition A (90-95% RH 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles -55C to +25C to +85C to +25C). Pulse Tolerance Curves Operating Temperature -40 C to +85 C 60 Hz 1/2 Cycle Inrush Pulse Tolerance Chemical Resistance Only the outside surfaces of the I r 50 Hz 1/2 Cycle Time Delay Curves case and the handles may be I Inrush Pulse Tolerance r 62, 64, 92 & 94 Time Delay Curves cleaned with detergents or 62, 64, 92 & 94 18x Time Delay Curves alcohol. Organic (hydrocarbon 22, 24, 32 & 34 16x Time Delay Curves 12x 22, 24, 32 & 34 based) solvents are not 10x recommended because they t t attack plastics. Caution should 8.33 16.67 5.0 10.0 20.0 4.165 be taken when solvents are used Time in Time in Milliseconds Milliseconds to clean and remove flux from terminals. Lubricants should not be introduced into the handle/ bushing openings 2. *Manufacturer reserves the right to change product specification without prior notice. Multiple of Rated Current Multiple of Rated Current