NOW PART OF PB-Series Equipment Leakage Circuit Interrupters PRODUCT WEBPAGE request sample, configure part The PB-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection and the familiar overcurrent tripping characteristics of a normal circuit breaker, reliably tripping when sensing low level ground or overcurrent faults. Based on the principles of hydraulic-magnetic design, the breaker also operates reliably when exposed to extreme heat or cold. This breaker series is available in one to three pole configurations and rated from .10-30 amps, 120VAC, 120/240VAC with max IC of 5,000 amps. 1-3 0.10-30 120/240 5,000A Max Poles Amps VAC Interrupting Capacity Typical Applications Marine Generators Lighting www.carlingtech.com 860.793.9281 sales carlingtech.comTech Specs Electrical Mechanical Maximum Voltage 120/240VAC 60 Hz Endurance 6,000 ON-OFF operations 6 per minute 4,000 mechanical with Current Ratings Standard current coils: 0.100, rated Current & Voltage. 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0 & Trip Free All PB-Series Circuit Breakers will 30.0 amps. Other ratings trip on overload or ground fault, available, see ordering scheme. even when Handle is forcibly held in the ON position. Insulation Resistance Minimum of 100 Megohms at 500 VDC Trip Indication The operating Handle moves positively to the OFF position when Dielectric Strength UL, CUL - 1500 V 60 Hz for one an overload or ground fault causes minute between all electrically the breaker to trip. isolated terminals. PB-Series circuit breakers comply with the 8mm spacing and 3750V 60 Hz Physical dielectric requirements from hazardous voltage to operator Number of Poles 1 - 3 poles, where the third pole is accessible surfaces and between neutral adjacent poles RESISTANCE, IMPEDANCE VALUES Internal Circuit Config. Series Trip Impedance Values from Line to Load Terminal from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Weight Approximately 65 grams/pole. 1000 Ampere Rating (2.32 ounces/pole.) CURRENT TOLERANCE Standard Colors Housing- Black Actuator - See 100 (AMPS) (%) Ordering Scheme. 0.10 - 5.0 15 10 5.10 - 20.0 25 O Environmental H 1 20.10 - 30.0 35 M Designed and tested in accordance with requirements of S specification MIL-PRF- 55629 and MIL-STD-202 as follows: Pulse Tolerance Curve 0.1 60 Hz 1/2 Cycle Inrush Pulse Tolerance I Shock Withstands 100 Gs, 6ms, sawtooth r 0.01 while carrying rated current per Method 213, Test Condition I. Ultra- Time Delay Curves short curves tested 90% of rated 0.001 22, 24, 26 0.01 0.1 1 10 100 12x current. AMPERE RATING t Vibration Withstands 0.060 excursion from CURRENT TOLERANCE (AMPS) (%) 8.33 4.165 16.67 10-55 Hz, and 10 Gs 55-500 Hz, at 0.100 - 5.0 15% Time in 5.1 - 20.0 25% Milliseconds Leakage To Ground rated current per Method 204C, 20.1 - 30.0 35% Test Condition A. Instantaneous FIGURE 1 Standard Must Trip 120/240VAC 60 Hz and ultrashort curves tested at 90% of rated current. Leakage Current 30 milliamps Ratings Moisture Resistance Method 106D, i.e., ten 24-hour cycles + 25C to +65C, 80-98% RH. Trip Time Minimum of 100 Megohms at 500 Salt Spray Method 101, Condition A (90-95% VDC. RH 5% NaCl Solution, 96 hrs). Test Button 300 ms Max. 100%, 40ms Max. Thermal Shock Method 107D, Condition A (Five 500% of must trip leakage current. cycles -55C to +25C to +85C to +25C). Impedance On unit face along side of actuator. Operating Temperature -35 C to +65 C Corrosion Tested FMG Test. 3 weeks 30C Tables 75% RH, 100ppb H2S, 20ppb CI2, Table A: UL Listed configurations and performance 200ppb NO2 capabilities as Circuit Breakers. Electrical Ratings Agency Approvals Voltage Current Interrupting Circuit UL 1053 Ground Fault Sensing and Rating Capacity Max Configuration Frequency Phase (Amps) (Amps) Relaying Equipment Rating Series 5000 UL 1500 Ignition Protection 120 60 1 .10 - 30 Series Ignition 3000 Protection 2. *Manufacturer reserves the right to change product specification without prior notice. Multiple of Rated Current