Energy Management Energy Analyzer Type EM210 Class B (kWh) according to EN50470-3 Class 1 (kWh) according to EN62053-21 Class 2 (kvarh) according to EN62053-23 Accuracy 0.5 RDG (current/voltage) Energy meter Instantaneous variables readout: 3 DGT Energies readout: 7 DGT System variables: W, var, PF, Hz, Phase-sequence. Single phase variables: VLL, VLN, A, PF, THD (A,V, up to the 15th harmonic) Energy measurements: total kWh (imported and exported) kvarh TRMS measurements of distorted sine waves (volt- ages/currents) Multi-use housing: for both DIN-rail and panel mount- Self power supply ing applications Dimensions: 4-DIN modules and 72x72mm Current inputs AV option: CT 5A Protection degree (front): IP40 Current inputs MV option: current sensor 333 mV (CTV Application adaptable display and programming proce- series) or ROG4K, Rogowski coil by Carlo Gavazzi dure (Easyprog function) without necessity of external integrator Easy connections management Detachable display Product description Three-phase energy meter urement and retransmission relevant working hours and tor. Voltage measurements with removable front LCD (transducer function). Possi- an hourcounter to link the carried out either by means display unit. The same unit bility to display also exported exported energy to produc- of direct connection or by can be used either as a active energy (e.g. in case of tion hours. Housing for DIN- means of potential trans- DIN-rail mounting or a panel regenerated energy in lifts or rail mounting with IP40 (front) formers. EM210 is provided, mounting energy meter. This similar applications) harmon- protection degree. Current as standard, with a pulsat- general purpose three-phase ic distortion information are measurements carried out ing output for active energy energy meter is suitable for available for the voltages and by means of external current retransmission. In addition a both active and reactive the currents, up to the 15th transformers transformers, 2-wire RS485 communica- energy metering for cost al- harmonic. An hourcounter 5A or 333mV (CTV series), or tion port is available as an location but also for main meter is available to link the ROG4K, Rogowski coil solu- option. electrical parameter meas- energy consumption to the tion without external integra- Specification are subject to change without notice EM210 DS 081116 1How to order EM210 72D AV5 3 X O X X Model Range code System Power supply Output 1 Output 2 Option Type Selection Range code System Power supply Options AV5: 230/400VLL AC, 5(6) 3: balanced and unbal- X: Self power supply X: none A or 1(6)A (*) anced load: from 40V to 480VAC 3-phase, 4-wire LL, 45 to 65 Hz (con- (CT connection) 3-phase, 3-wire nection VL2-VL3) AV6: 120/230VLL AC (without N connection) 5(6)A or 1(6)A (*) 2-phase, 3-wire (VT/PT and CT con- 1-phase, 2-wire nections) MV5: 230/400VLL AC, 0.333V (current sen- sor CTV series or ROG4K connection) MV6: 120/230VLL AC, 0.333V (VT/PT and current sensor CTV series or ROG4K connection) Output 1 Output 2 (*) the range 1(6)A is avai- lable but not in complian- O: Single static output X: None ce with the EN50470-3 (opto-mosfet) S: RS485 port standard. Specification are subject to change without notice EM210 DS 081116 2