Energy Management Power Analyzer Type WM14-96 Basic Version Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5 F.S. (current/voltage) Power analyzer Display of instantaneous variables: 3x3 digit Display of energies: 8+1 digit System variables and phase measurements: W, W , dmd var, VA, VA , PF, V, A, An, A , Hz dmd dmd A , A , W indication max dmd max dmd max Energy measurements: kWh and kvarh Hour counter (5+2 DGT) TRMS meas. of distorted sine waves (voltages/currents) Power supply: 24V, 48V, 115V, 230V, 50-60Hz 18 to 60VDC Protection degree (front): IP65 Optional dual pulse output Front dimensions: 96x96mm Alarms (visual only) V , An LN Optional RS422/485 serial port Optional galvanically insulated measuring inputs Product Description How to order WM14-96 AV5 3 D PGX Model 3-phase power analyzer with (front) protection degree built-in programming key- Range code IP65, and optional RS485 pad. Particularly recom- serial port or dual pulse out- System mended for displaying the put. Parameters pro- Power supply main electrical variables. grammable by means of Option Housing for panel mounting, CptBSoft. How to order CptBSoft CptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables. Type Selection Range codes System Power supply Options AV5: 380/660V /5(6)AAC 3 : 1-2-3-phase, L-L A: 24VAC X: None balanced/unbalanced VL-N: 185 V to 460 V S: RS485 port -15+10%, 50-60Hz load,with or without VL-L: 320 V to 800 V SG: RS485+galvanic insu- B: 48VAC neutral AV6: 120/208V /5(6)AAC lated measurig inputs L-L -15+10%, 50-60Hz PG: Dual pulse output + VL-N: 45 V to 145 V C: 115VAC galvanically insulated VL-L: 78 V to 250 V -15+10%, 50-60Hz measuring inputs. Phase current: 0.03A to 6A D: 230VAC Neutral current: 0.09 to 6A -15+10%, 50-60Hz 3: 18 to 60VDC (not available in case of SG or PG options) Input specifications Rated inputs 0.03A to 0.25A: (2% FS +5DGT) Current X-S options 3 (non insulated each other) Active energy X-S option Class 2 (start up I: 30mA) Current SG-PG options 3 (insulated each other) Reactive energy X-S option Class 3 (start up I: 30mA) Voltage 4 Active energy SG-PG opt. Class 1 (start up I: 30mA) Reactive energy SG-PG opt. Class 2 (start up I: 30mA) Accuracy (display, RS485) with CT=1 and VT=1 AV5: Frequency 0.1Hz (48 to 62Hz) ( 25C 5C, R.H. 60%) 1150W-VA-var, FS:230VLN, 400VLL AV6: 285W-VA-var, Additional errors FS:57VLN, 100VLL Humidity 0.3% FS, 60% to 90% RH Current 0.25 to 6A: (0.5% FS +1DGT) Temperature drift 200ppm/C 0.03A to 0.25A: (0.5%FS+7DGT) Sampling rate 1400 samples/s 50Hz Neutral current 0.25 to 6A: (1.5% FS +1DGT) 1700 samples/s 60Hz 0.09A to 0.25A: (0.5%FS+7DGT) Phase-phase voltage (1.5% FS +1 DGT) Display refresh time 700ms Phase-neutral voltage (0.5% FS + 1 DGT) Display Type LED, 14mm Active and Apparent power, 0.25 to 6A: (1% FS +1DGT) Read-out for instant. var. 3x3 DGT 0.03A to 0.25A: (1% FS Read-out for energies 3+3+3 DGT (max indication: +5DGT) 999 999 99.9) Reactive power 0.25 to 6A: (2% FS +1DGT) Specifications are subject to change without notice WM14 96 DS ENG 230317 1WM14-96 Input specifications (cont.) Display (cont.) Input impedance (X-S options) Read-out for hour counter 1+3+3 DGT (max. indication: 380/660V (AV5) 1 m 5% L-L 9 999 9.99) 120/208V (AV6) 453 K 5% L-L Measurements Current, voltage, power, Current 0.02 power factor, frequency, Input impedance (PG-SG options) energy, TRmS measurement 380/660V (AV5) 1 m 1% L-L of distorted waves. 120/208V (AV6) 1 m 1% L-L Coupling type Direct Current 0.02 Crest factor < 3, max 10A peak Frequency 48 to 62 Hz Overload protection Continuos voltage/current 1.2 F.S. For 500ms: voltge/current 2 Un/36A RS485 Serial Port Specifications RS422/RS485 (on request) Data (bidirectional) Type multidrop Dynamic (reading only) System, phase variables and bidirectional (static and energies dynamic variables) Static (writing only) All configuration parameters Connections 2 or 4 wires, max. distance Data format 1 bit di start , 8 data bit, 1200m, termination directly no parity, 1 stop bit on the instrument Baud-rate 9600 bit/s Addresses 1 to 255, key-pad selectable Protocol mODBUS/JBUS CptBSoft software: parameter programming and reading data CptBSoft multi language software to NT/XP. program the working Working mode Two different working parameters of the power modes can be selected: analyzer and to read the - management of a local energies and the RS485 network instantaneous variables. - management of The program runs under communication from a single Windows 95/98/98SE/2000/ instrument to PC (RS232) Data access By means of RS485 serial port. Dual pulse output 5 Digital outputs (on request) Electrical life: min 2*10 cycles 6 Pulse outputs mechanial life: 5*10 cycles Number of outputs 2 (one for kWh one for kvarh) Pulse duration 100ms <120ms (ON) Number of pulses From 0.01 to 999 in 100ms (OFF) compliance with the According to EN622053-31 following formula: Insulation By means of relays, Psys max (kW or 4000 V outputs to RmS kvar)*pulses (pulses/kWh measuring inputs, or kvarh) <14400 4000 V output to RmS Output type Relay supply input. min current: 0.05A 250VAC/30VDC Insulation between the two max current: 5A 250VAC/30VDC outputs: 1000V RmS 2 Specifications are subject to change without notice WM14 96 DS ENG 230317