EM26 96 Energy Management Energy Analyzer Type EM26 96 Class 1 (kWh) according to EN62053-21 Class B (kWh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy 0.5% RDG (current/voltage) Dual colour backlight: no backlight, blue or white (selectable) Energy analyzer Instantaneous variables readout: 4 DGT Energies/gas/water readout: 8 DGT System variables: VLL, VLN, Admd, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd max, var, PF, Hz, Phase-sequence. Single phase variables: VLL, VLN, A, VA, W, var, PF Energy measurements: total and partial kWh and kvarh or based on 4 different tariffs single phase measurements Gas, cold water, hot water, kWh remote heating measurements Hour counter (6+2 DGT) Harmonic analysis (FFT) up to 15th harmonic (current/voltage) TRMS measurements of distorted sine waves (voltages/currents) Universal power supply: 90 to 260AC/VDC M-bus communication by means of VMU-B adapter 3 digital inputs for tariff selection, DMD synch or gas/water (hot- Application adaptable display and programming cold) and remote heating metering (on request) procedure (Easyprog function) 3 digital outputs for pulses or for alarms or as a mix of them Easy connections management (on request) Certified according to MID Directive (option PF only): Front dimensions: 96x96mm see how to order below Protection degree (front): IP50 Other versions available (not certified, option XX): RS485 serial output (on request) (MODBUS-RTU), iFIX SCADA see how to order on the next page compatibility Product Description Three-phase energy analyzer and for cost allocation. Hous- over the meter can be provided outputs, or for remote control. with built-in configuration joy- ing for panel mounting with with digital outputs that can be RS485 communication port and stick and LCD data displaying IP50 (front) protection degree. used: for pulses proportional to 3 digital inputs are available as particularly indicated for active External Current and potential the active and reactive energy an option. and reactive energy metering transformers connection. More- being measured or for alarm How to order EM26 96 AV5 3 H O3 S1 PF A Certified according to MID Directive, Module B and Module D of Annex II, for legal metrology Model MID relevant to active electrical energy meters (see Range code Annex V, MI003, of MID). Can be used for fis- System cal (legal) metrology. Only the total positive energy meter is Power supply certified according to MID. Inputs/Outputs Communications Option Measurement Type Selection Options Communication Range codes System AV5: 230 V /400V LN LL PF: Certified according to 3: 3-phase, 4-wire XX: none 1/5(10)A MID Directive. Can be S1: RS485 port V : 160 V to 480 V LN LN used for fiscal (legal) V : 277 V to 830 V LL LL metrology. Input/Output Power supply AV6: 120 V /208V LN LL 1/5(10)A V : 40 V to 144 V LN LN H: 90 to 260VAC/DC (48 O1: single open collector type V : 70 V to 250 V (pulse or alarm) LL LL to 62Hz) O3: 3 open collector type (mixed combination of pulse, alarm and/or remote output) R2: dual relay type (functions as per O3) I3: 3 digital inputs for tariff selection or Gas/water/ energy/remote heating metering AV5 3 H O1 XX AV6 O3 S1 NOTE: please check the A R2 PF availability of the needed B code on the verification path diagram on left before order. I3 S1 Specifications are subject to change without notice EM2696 DS ENG 130117 1 Range System Power supply Input/Output Communication Option MeasurementEM26 96EM26 96 How to order EM26 96 AV5 3 H O3 S1 XX STANDARD Model Range code Not certified according to MID directive. Cannot be System used for fiscal (legal) metrology. Power supply Input/Output Communication Options Type Selection Range codes System Power supply Input/Output AV5: 230 V /400V LN LL 3: balanced and H: 90 to 260VAC/DC O1: single open collector 1/5(10)A unbalanced load: (48 to 62Hz) type (pulse or alarm) V : 160 V to 480 V LN LN O3: 3 open collector type 3-phase, 4-wire V : 277 V to 830 V (mixed combination of LL LL 3-phase, 3-wire pulse, alarm and/or AV6: 120 V /208V LN LL 2-phase, 3-wire remote output) 1/5(10)A 1-phase, 2-wire R2: dual relay type (functions V : 40 V to 144 V LN LN as per O3) Communication V : 70 V to 250 V LL LL I3: 3 digital inputs for tariff selection or Gas/water/ energy/remote heating XX: none metering S1: RS485 port Options XX: none AV5 3 H O1 XX XX AV6 O3 S1 R2 I3 NOTE: please check the availability of the needed code on the verification path tables on left before order. 2 Specifications are subject to change without notice EM2696 DS ENG 130117 Range System Power supply Input/Output Communication Option