Dupline Transmitter with Built-in Temperature Sensor Type G 8911 1010 AnaLink temperature transmitter with built-in Pt 1000 sensor Temperature range: -30C to +60C (-22 to +140F) Uses only 1 channel Channel coding by GAP 1605 M12 connection Easily mountable Supplied by Dupline Product Descrip tion Ordering Key G 8911 1010 The sensor is mounted right etc. The sen sor meas ures the Type: Dupline at the loca tion where the tem- temper a ture and transmits Type perature is to be meas ured, the value to the control ler G e.g. freezer cabinets in super 3890 0030, which then per - mar kets, cold storage rooms forms the logging and alarm - ing. Type Selection General Speci fi ca tions Supply Ordering no. Channel programming By GAP 1605 1 channel Channel assignment 1 channel, Pt 1000 sensor freely programmable Environment By Dupline G 8911 1010 Degree of protection IP 67 Operating temperature -30 to +60C (-22 to +140F) Storage temperature -55 to +85C (-67 to +185F) Supply Speci fi ca tions Mechanical resistance Power supply Supplied by Dupline Shock 15 G (11 ms) Rated operational current Typ. 800 A Vibration 2 G (6 to 55 Hz) Connection M12 plug Housing Flat-pack Material Housing Polycarbonate Plug Nylon Colour Light grey Dimensions (l x w x d) 67 x 35 x 15 mm Mounting Direct wall mounting*) *) To measure the air temperature, the sensor should not be wall-mounted, but should be exposed to air flow. Sensor Speci fi ca tions Sensor Pt 1000 (built-in) Time constant Typ. 450 s Temperature measuring (air flow = 0 m/s) range -30 to +60C (-22 to +140F) Typ. 350 s Temperature probe Pt 1000 (built-in) (air flow = 1 m/s) Accuracy See curve below Resolution 8 bits (approx. 0.35 K/LSB) Max. error (C) 1,5 1,0 0,5 0 Temp. (C) -30 -20 -10 0 10 20 30 40 50 60 Specifications are subject to change without notice (19.10.2015) 1 G 8911 1010 Distance versus No. of Sensors Dimensions DC loop resistance () Example: Max. distance for 75 sen- sors D 8911 1010: 75 x 0.8 mA = 60 mA loop resistance ~ 35 . If 1.5 2 mm ca ble 12 /km is used, the distance is: 35 = 1.45 km max. 2 x 12 /km Dupline load (mA) from AnaLink sensors Connections Accessories Coding cable GTS-CAB* M12 plug with terminals Pin 1: Dupline D+ Angular M12 plug CONM14NF-A Pin 4: D- Straight M12 plug CONM14NF-S Cable with angular plug CONM13NF-A** Cable with straight plug CONM13NF-S** Standard cable with M12 plug (IEC 60947-5-2) * Delivered with the G 3890 0030. with 4 wires: Brown: Dupline (1) D+ ** Indicate length 2 m or 5 m. Black: (4) D- Blue: (3) D- White: (2) D- with 3 wires (1-3-4): Brown: Dupline (1) D+ Black: (4) D- Blue: (3) D- with 2 wires (1-4) Brown: Dupline (1) D+ Blue: D- Note: All wires must be connected. 2 Specifications are subject to change without notice (19.10.2015)