Programming Unit Du line Type GAP 1605 Fieldbus Installationbus Portable programming unit Individual coding of every input or output Group coding of an entire module Reading of codes Editing of channel codes On/off-line coding of Dupline modules type G .... LED display 4 x 8 LEDs 5-key tactile keyboard Battery powered Easy-to-handle plug-type connection Switch for turning power on/off Product Description Ordering Key GAP 1605 Programming unit for Dupline and 8 successive channels or Type: modules G..(..) .... Provides individually for each I/O. Dupline Programmer means of reading and pro- Unused inputs/outputs can be Type no. gramming of channel codes. defined as non-coded. Coding of I/O s as either 2, 4 Supply Specifications Type Selection Supply Ordering no. Power supply 9 V Alkaline 400 mAH Internal battery GAP 1605 Battery type IEC 6F22 Rated operational power Stand-by < 25 A Operating < 22 mA Battery lifetime Typ. 1 year Product Specifications General Specifications Output Environment Connection 6/6 modular socket Degree of protection IP 40 Pollution degree 3 (IEC 60664) Display 4 x 8 dots Operating temperature 0 to +50C (+32 to +122F) Type LED Storage temperature -20 to +60C (-4 to +140F) Size 1.8 mm Humidity (non-condensing) 20 to 80% RH Keyboard Tactile keys No. of keys 5 Mechanical resistance Shock 15 G (11 ms) Cable GAP 1605 to Dupline system Vibration 2 G (6 to 55 Hz) Connectors 2 x 6/6 modular plugs Length 75 cm Material ABS, grey Weight 225 g Specifications are subject to change without notice (04.03.2009) 1 Dupline is a registered trademark. A product of the CARLO GAVAZZI GroupGAP 1605 Du line Fieldbus Installationbus Mode of Operation The GAP 1605 is a portable Group - Key Prog - Key It is possible to change all programming unit used for When the displayed I/O- eight Inputs/Outputs, even reading or programming Used to select the Group coding corresponds to the though some Dupline mod- channel code(s) in the series address within the range A desired channel configura- ules are built for only 1, 2 or of Dupline products. to P. The Group LED will tion, the codes will be 4 Inputs/Outputs. shift one position right for downloaded to the Dupline each key activation. module when pressing the Prog key. The external switch turns To exit single channel pro- the power on/off. gramming, just keep the When the battery is installed Channel - Key In/Out key pressed for 2 and the power is on, the After programming is exe- seconds. GAP 1605 is ready for use. Used to select the chan- cuted, a verification takes Connect the cable between nel(s) within the group. The place. If this verification the programming unit and a Channel LED will shift right fails, all activated LEDs in Dupline module type G.. one, two or four positions, the display will flash two Output status setting depending on the number of times, and the programming inputs/outputs. If consecu- unit will switch off. On receivers it is possible to tive channels are selected, configure the status of the 5 keys provide the means of then pressing the Channel outputs during Dupline fail- operating the GAP 1605: key will have no effect. ure. Normally, any output of two keys are used for read- If such behaviour occurs re- a receiver will go off during ing and programming, two peatedly on the same mod- Dupline failure. In some cas- keys for changing Groups ule, the module may be es the inverted function is and Channels and one key Read / On - Key faulty. If several modules fail desirable (e.g. light applica- for selecting the desired to download, the GAP 1605 tions - turn on light if the Input/Output. Used to turn on the GAP may be faulty. Dupline is down). 1605 and to read the chan- nel codes of the connected module. When the reading is The current coding is dis- completed, the display will Individual In/Out channel To change output status, the played by 4 x 8 LEDs. The show the channel code of programming GAP 1605 must be put into top row of LEDs displays the the module: either 1, 2, 4 or configuration mode. This is selected input or output. 8 inputs/outputs. The GAP 1605 features an done as follows: The two middle rows display additional mode of single- Remove any connected the current channel group, channel editing. Pressing Dupline system. while the bottom row dis- In/Out for more than 2 Keep both In/Out and plays the current channel 2, 4 or 8 In/Out LED s being seconds will change the Group pressed, while code. ON indicates that consecu- operating mode to single- pressing Read/On . tive channel codes are allo- point programming. The cated to the I/O s, e.g. input In/Out key is now used 1 coded to P1, input 2 to P2 to select one of the eight In/Out - Key ... input 8 to P8. possible inputs/output, thus The first In/Out LED now making individual channel turns on. Connect the Dupline This key is used to scroll coding possible. The In/Out- system, and press Read/ through the I/O s of a mod- LEDs assign the display On . If output status is set, ule. If a new module is con- If only one In/Out LED is channel code to the corre- then channel LED 1 will illu- nected or if consecutive ON, then the I/O s are cod- sponding physical input/out- minate. Pressing Channel channel codes are allocated ed individually, e.g. input 1 put of the module. will toggle the output status to the I/O s, pressing the to C5, input 2 to D4 etc. The On/Off. In/Out key has no effect code for each I/O is indicat- Press Prog to store. since all Dupline modules ed by a group LED and a If Read/On is pressed are preprogrammed to their channel LED. In singlemode the Chan- when no Dupline system is physical number of inputs/ nel key also has the ability connected, the LEDs will outputs. This key is also to disable an In/Out-position. flash to indicated a false used to switch between Channel must simply be condition. Only a successful consecutive and individual If the GAP 1605 is not con- pressed past channel 8, reading will reset this condi- coding of the I/O s. To nected to a Dupline system, whereby both the Channel tion. change the mode, keep it will turn off within two se- LED and the Group LED will In/Out pressed for more conds. turn off. To reenable, just than 2 seconds. press Channel again. 2 Specifications are subject to change without notice (04.03.2009) Dupline is a registered trademark. A product of the CARLO GAVAZZI Group