Dupline Carpark Master Zone Counter (MZC) Type GPMZC-SET (complete) Controller in the Dupline zone counting system Micro Linux PC with Ethernet port and Web-server Connects up to 120 count sensors via Dupline L 3-wire 1 bus Dupline ultrasonic carpark sensors can be used directly on the L bus 1 Loop detectors or Photoelectric sensors can be used when connected to Dupline L input module 1 Manages up to 3840 parking spaces in multiple zones Each zone can have multiple entry and exit points Easy configuration, monitoring and count adjustment via web-server Mixed systems with zone counting and single space detection possible Option to detect the split between handicap and stan- dard spaces occupancy Optional PC software for real-time monitoring and his- torical occupancy data analysis Product Description Ordering Key The GPMZC-SET is a pro- itor the zone count system grammable integrated using a Smartphone or other unit specially designed for Ethernet based equipment. Carpark applications. The The two galvanic separated GPMZC-SET is a combina- channels generators supply tion of 3 modules, one con- the two busses L and L 1 2 troller and two channel gen- with power and Dupline . erators for the L and L bus. The GPMZC-SET can easily 1 2 The controller includes dedi- be combined with the single cated functions for counting spot Detection system. The based on the count sensors data from the systems can connected to the L bus. A be monitored and controlled 1 web-server in the controller from the Dupline Carpark gives the user unique oppor- Software. tunity to modify or mon- Type Selection Housing Mounting Supply: 24 VDC 20% 2 DIN DIN-rail GPMZC-SET Count Module: GP32950030700 Supply Specifications Power supply Overvoltage cat. II Reverse polarity protection Yes (IEC 60664-1, par. 4.3.3.2) Connection A1 (+) and A2 (-) Rated operational voltage 15 to 24 VDC 20% Power off delay 1 s Rated impulse voltage 500V (1,2/50s) (IEC 60664-1, tab. F.1) Rated operational power 5 W Main Hardware Characteristics Memory Micro SD not in use Right side Compatible with GP32900003700 Communication ports RS485 2 ports USB ports Ethernet 1 port, for Internet/LAN Mini USB Only for internal use connection Host function Not in use Auxiliary bus HS BUS Specifications are subject to change without notice (23.06.2017) 1 GPMZC-SETGPMZC-SET RS485 Communications Ports Number of ports 2 Data format Selectable: 1 start bit, 7/8 Purpose COM1: Modbus slave data bit, no/odd/even/ par- COM2: Modbus slave ity,1/2 stop bit Type Multidrop, bidirectional Baud-rate 9600 bits/s Connections 2-wire. Max. distance Insulation See the table Insulation 1000m between inputs and out- Protocol MODBUS RTU puts Ethernet Port Rated inputs HTTP WEB server 80 20 IP configuration Static IP / Netmask / Connections RJ45 10/100 BaseTX Default gateway Max. distance: 100m DNS Primary and secondary Insulation See Insulation between DNS as a static or dynamic inputs and outputs table. management (using DHCP server if configured) Port N. of connec- tions HS Bus Specs (right side) Bus type RS485 high speed bus modules which drive the L1 and L2 buses must be Function Connection to master connected on the right side channel generator module of the GP32950030700 GP32900003700 Connection By local bus on the right side Note: The two GP32900003700 LEDs Indication Green LED: ON Flashing: 200ms ON 200ms BUS Blue LED: USB ON: power ON OFF, communications OK OFF: no communication is Not in use OFF: power OFF present on the HS BUS COM 2 ON: communication error on Red LED: STATUS Yellow LEDs: OFF: no communications on HS BUS Not in use COM 1 RS485 B Flashing: communication OK OFF: no communications on Flashing: 200ms ON 600ms on HS BUS RS485 A OFF, no answer from the Flashing: 200ms ON 600ms slave OFF, no answer from the Flashing: 200ms ON 200ms slave OFF, communications OK 2 Specifications are subject to change without notice (23.06.2017)