Timers Delay on Operate Types HAA08, HAA14 Time range 0.1 s to 100 h Dip-switch selection of time range Knob adjustable time setting Dip-switch selection of operating mode (4 functions): Op - delay on operate R - symmetrical recycler ON first Rb - symmetrical recycler OFF first In - interval Automatic start Repeatability: 0.3% on full scale Output: 8 A DPDT relay (HAA08), 5 A 4PDT relay (HAA14) 21.5 x 28 mm housing 8-pin, 14-pin blade socket for HAA08, HAA14 respec- tively LED indication for relay status and power supply ON Product Description Ordering Key HAA 08 D M24 Delay on operate timer with Housing 21.5 x 28 mm with Housing 4 functions and selectable 8-pin and 14-pin blade Function time ranges from 0.1 sec- socket. Type onds to 100 hours. Item number Output Power supply Type Selection Mounting Output Plug Supply: 24 to 240 VAC/DC Socket DPDT 8-pin HAA08DM24 Socket 4PDT 14-pin HAA14QM24 Time Specifications Output Specifications Time ranges Output DPDT or 4PDT relay Dip-switch selectable Rated insulation voltage 250 VAC 0.1 to 1.0 s Contact ratings (AgCe) 1 to 10 s HAA08 (DPDT) 0.1 to 1 min Resistive loads AC 1 8 A 250 VAC 1 to 10 min DC 12 8 A 30 VDC 0.1 to 1 hour Small inductive loads AC 15 2.5 A 250 VAC 1 to 10 hour DC 13 2.5 A 30 VDC 10 to 100 hour HAA14 (4PDT) Setting accuracy 5% on full scale 200 ms Resistive loads AC 1 5 A 250 VAC DC 12 5 A 30 VDC Repeatability 0.3% on full scale Small inductive loads AC 15 1.5 A 250 VAC or 200 ms DC 13 1.5 A 30 VDC Time variation 7 Mechanical life 1 x 10 operations Within rated power supply 0.05% /V 5 Within ambient temperature 0.2% /C Electrical life 10 operations (HAA08: Reset at 8 A, 250 VAC / 30 VDC, Power supply interruption >100 ms cos = 1 HAA14: at 5 A, 250 VAC / 30 VDC, cos = 1) Operating frequency 18000 operations/h Dielectric strength Dielectric voltage 2 kVAC (rms) Rated impulse withstand volt. 3.6 kV (1.2/50 s) Specifications are subject to change without notice (08.05.09) 1HAA08, HAA14 Supply Specifications General Specifications (cont.) Power Supply Overvoltage cat II Environment Rated operational voltage (IEC 60947-1) Degree of protection IP 50 (front panel) through terminals: 13, 14 24 to 240 VDC + 10% - 15% Operating temperature -10 to +55 C, R.H. < 85% 24 to 240 VAC + 10% -15%, Storage temperature -10 to +55 C, R.H. < 85% 45 to 65 Hz Housing Rated operational power Dimensions 21.5 x 28 mm AC supply 4 VA Material PA66 DC supply 1.5 W Weight Approx. 95 g Approvals UL (240 V 5A general use, 240 V 1/10 hp, all models) General Specifications CSA (240 V 5A general use, 240 V 1/10 hp, all models) Indication for CE marking Yes Power supply, relay and timing status LED, yellow (steady with EMC Electromagnetic Compatibillity relay closed, flashing 10 Hz Immunity According to EN 61000-6-2 when timing with relay Emission According to EN 61000-6-3 open, flashing 2 Hz after In function set time ending (relay open)) Mode of Operation Function Op Function R Function Rb Function In Delay on operate Symmetrical recycler Symmetrical recycler Interval The set delay period begins (ON first) (OFF first) The relay operates and the as soon as the power supply The relay operates and the The time period begins as time period begins as soon is connected. At the end of time period start as soon as soon as the power supply is as the power is applied. The the set delay the relay oper- the power supply is applied. applied. The relay is OFF relay releases at the end of ates and does not release At the end of the first set during the set delay period, the time period or when the until the power supply is time period, the relay releas- after this time it operates for power supply is disconnect- interrupted for at least 100 es. At the end of the second the same time period. This ed for at least 100 ms. ms. time period (equal to the sequence continues with first), the relay operates equal OFF- and ON-time again. This sequence con- periods until power supply is tinues with equal ON- and interrupted for at least 100 OFF- time periods until the ms. power supply is interrupted for at least 100 ms. Function/Range/Time Setting Centre knob: Adjust the time range setting the DIP switches 1 to 3, the Time setting on relative function setting the DIP switches 4 and 5 as shown below. scale: 1 to 10 with respect to the chosen range. No function Function selection ON ON: Op delay on operate ON OFF: In interval OFF ON: Rb symmetrical recycler (OFF first) OFF OFF: R symmetrical recycler (ON first) Time range OFF OFF OFF: 0.1 to 1 s ON OFF OFF: 1 to 10 s OFF ON OFF: 0.1 to 1 m ON ON OFF: 1 to 10 m OFF OFF ON: 0.1 to 1h ON OFF ON: 1 to 10 h OFF ON ON: 10 to 100 h 2 Specifications are subject to change without notice (08.05.09)