WM30 96 Energy Management Smart Modular Power Analyzer Type WM30 96 Class 0.5S (kWh) according to EN62053-22 Class 2 (kvarh) according to EN62053-23 Accuracy 0.2% RDG (current/voltage) Instantaneous variables readout: 4x4 DGT Energies readout: 9+1 DGT System variables: VLL, VLN, A, VA, W, var, PF, Hz, Phase-sequence-asymmetry-loss. Single phase variables: VLL, VLN, AL, An (calculated), VA, W, var, PF Both system and single phase variables with average and max calculation Harmonic analysis (FFT) up to the 32nd harmonic (current and voltage) Energy measurements (imported/exported): total and Communication protocol: MODBUS-RTU partial kWh and kvarh MODBUS TCP/IP Ethernet port (on request) Energy measurements according to ANSI C12.20 CA BACnet-IP over Ethernet port (on request) 0.5, ANSI C12.1 BACnet MS/TP over RS485, BTL approved (on request) Run hours counter (8+2 DGT) Profibus DP V0 port, PROFIBUS Nutzerorganisation Real time clock function e.V. approved (on request) Application adaptable display and programming Up to 2 digital outputs (pulse, alarm, remote control) procedure (Easyprog function) (on request) Universal power supply: 24-48 VDC/AC, 100-240 VDC/AC Up to 4 freely configurable virtual alarms Front dimensions: 96x96 mm Up to 2 analogue outputs (+20mA, +10VDC) (on request) Front protection degree: IP65, NEMA4X, NEMA12 One RS232 and RS485 port (on request) Product Description How to order WM30-96 AV5 3 H R2 A2 S1 XX Model Three-phase smart power either for pulse proportional to the analyzer with built-in advanced active and reactive energy being Range code configuration system and LCD measured or/and for alarm outputs. System data displaying. Particularly The instrument can be equipped Power Supply recommended for the with the following modules: RS485/ A Outputs measurement of the main RS232, Ethernet, BACnet-IP, B Outputs electrical variables. WM30 is BACnet MS/TP or Profibus DP Communication based on a modular housing for V0 communication ports, pulse Option panel mounting with IP65 (front) and alarm outputs. Parameters protection degree. Moreover, programming and data reading the analyzer can be provided can be easily performed by means with digital outputs that can be of UCS (Universal Configuration Software). Type Selection Range codes System Power supply A Outputs AV4: 3x220(380)...3x400(690)V 3: balanced and H: 100-240 +/-10% (90 XX: none 1(2)A unbalanced load: to 255) VDC/AC O2: Dual channel static V : 220 to 400 V LN LN 3-phase, 4-wire (50/60 Hz) output V : 380 to 690 V LL LL 3-phase, 3-wire L: 24-48 +/-15% (20 to R2: Dual channel relay AV5: 3x220(380)...3x400(690)V 2-phase, 3-wire 55) VDC/AC output 5(6)A 1-phase, 2-wire (50/60 Hz) V : 220 to 400 V LN LN V : 380 to 690 V LL LL Options Communication B Outputs AV6: 3x57.7(100)...3x133(230)V 5(6)A XX: none XX: none XX: none V : 57.7 to 133 V LN LN S1: RS485/RS232 port A2: Dual channel 20mA V : 100 to 230 V LL LL E2: Ethernet / Internet DC output AV7: 3x57.7(100)...3x133(230)V port V2: Dual channel 10V 1(2)A B1: BACnet (IP) over DC output V : 57.7 to 133 V LN LN Ethernet V : 100 to 230 V LL LL B3: BACnet (MS/TP) over RS485 P1: Profibus DP/V0 port Specifications are subject to change without notice WM30 96 DS 071020 1WM30 96 Position of modules and combination Ref Description Main features Part number Pos. A Pos. B Pos. C Inputs/system: AV5.3 1 WM30 AV5 3 H Power supply: H Inputs/system: AV6.3 2 WM30 AV6 3 H Power supply: H Inputs/system: AV4.3 3 WM30 AV4 3 H Power supply: H Inputs/system: AV7.3 4 WM30 AV7 3 H Power supply: H WM30 base provided with display, power supply, measuring inputs Inputs/system: AV5.3 WM30 AV5 3 L Power supply: L Inputs/system: AV6.3 WM30 AV6 3 L Power supply: L Inputs/system: AV4.3 WM30 AV4 3 L Power supply: L Inputs/system: AV7.3 WM30 AV7 3 L Power supply: L 2-channel 5 Dual relay output (SPDT) M O R2 X Alarm or/and pulse output 2-channel 6 Dual static output (AC/DC Opto-Mos) M O O2 X Alarm or/and pulse output 7 Dual analogue output (+20mADC) 2-channel M O A2 X 8 Dual analogue output (+10VDC) 2-channel M O V2 X 9 RS485 / RS232 port module Max. 115.2 Kbps M C 485 232 X 10 Ethernet port module RJ45 10/100 BaseT M C ETH X 11 BACnet-IP port module Based on Ethernet bus M C BAC IP X 12 BACnet-MS/TP port module Over RS485 M C BAC MS X Profibus DP V0 13 Profibus module M C P B X Over RS485 NOTE: The position of the modules shall respect the sequence A-B-C. Possible arrangements are M, M-A, M-B, M-C, M-A-B, M-A-C, M-B-C and M-A-B-C where M is the basic module (WM30-96). It is possible to use the WM30-96 without any additional module as a simple indicator. 2 Specifications are subject to change without notice WM30 96 DS 071020