Photoelectrics
Through-beam, Transistor Output
Type PB10CNT15..
Elevators, Escalators and Entrance control
Range 15 m
Modulated, infrared light
Supply voltage: 10 to 30 VDC
Output: 100 mA, NPN or PNP type
Make or break switching
LED for output indication or power supply
Protection: reverse polarity, short circuit, transients
Cable versions with or without connector
Emitter mute and power adjustment
Product Description Ordering Key
PB10CNT15NO-C1
Type
The PB10CNT. is a through known for its high long term
Housing style
beam sensor set specially relaibility mute. The emitter
Housing size
designed for Elevators, has a mute input to turn it
Housing material
Escalators, Entrance control off for evaluation of the sen-
Sensor code
to meet the requirements in sor function.
Detection principle
the door market. The hous- Available in 10-30 VDC
Sensing distance
ing is very robust and is version.
Output type
Output configuration
Connection type
Cable connector
Type Selection
Housing Range Con- Ordering no. Ordering no. Ordering no. Ordering no. Ordering no.
diameter S nec- Receiver Receiver Receiver Receiver Emitter
n
tor NPN, NO NPN, NC PNP, NO PNP, NC
10 mm 15 m NO PB10CNT15NO PB10CNT15NC PB10CNT15PO PB10CNT15PC PB10CNT15
10 mm 15 m YES PB10CNT15NO-C1 PB10CNT15NC-C1 PB10CNT15PO-C1 PB10CNT15PC-C1 PB10CNT15-C1
Note: Please order emitter and receiver separately
Specifications Emitter
Rated operational volt. (U ) 10 to 30 VDC Light source LED, 880 nm
B
Ripple (U ) 10%
rrp Light type Infrared, modulated
Supply current 20 mA
Optical angle 2
Protection Reverse polarity, transients
Indication function
Power supply ON LED, green
Control input
Mute input ON LED, green flashing
Normal oper. > 1.5 VDC
Power adjustment
Mute < 1.2 VDC
R ~ 3 k -10 k 0 - 100%, in 20 steps
x
Specifications are subject to change without notice (25.02.05) 1PB10
Specifications Receiver
Rated operating dist. (Sn) 15 m Optical angle 2
Blind zone None OFF-state current (I ) 100 A
r
Temperature drift 0.4%/C Voltage drop (U ) 1.6 VDC @ 100 mA
d
Hysteresis (H) 3 - 20% Protection Short-circuit, reverse pola-
rity, transients
Rated operational volt. (U ) 10 to 30 VDC (ripple included)
B
Operating frequency (f) 100 Hz
Ripple (U ) 10%
rrp
Response time OFF-ON (t ) 3.5 ms
ON
Output current
ON-OFF (t ) 6.5 ms
OFF
Continuous (I ) 100 mA
e
Short-time (I) 100 mA, Power ON delay (t ) 300 ms
v
(max. load capacity 100 nF)
Output function
No load supply current (I ) 13 mA NPN or PNP Make or break (NO or NC)
o
Minimum operational current (I ) 0.5 mA Indication function
m
Output ON LED, yellow
Ambient light >20.000 LUX
General Specifications
Environment Rated insulation voltage 50 VDC
Overvoltage category II (IEC 60664/60664A,
Housing material
60947-1)
Body PC black
Pollution degree 3 (IEC 60664/60664A,
Connection
60947-1)
Cable PVC, grey, 5 m,
Degree of protection IP 67 (IEC 60529, 60947-1)
2
3 x 0.12 mm , 3.2 mm
Temperature
Weight
Operating -20 to +50C (-4 to +122F)
Emitter 80 g
Storage -25 to +80C (-13 to +176F)
Receiver 80 g
Vibration 10 to 150 Hz, 0.5 mm/7.5 g
CE-marking EN12445, EN12453,
(IEC 60068-2-6)
EN12978
Shock 2 x 1 m & 100 x 0.5 m
(IEC 60068-2-32)
Operation Diagram
tv = Power ON delay
Power supply
Target emitter present
Object present
Break (NC) Output ON
Make (NO) Output ON
Mute active 1.2 VDC
Installation Hints
To avoid interference from inductive voltage/ Relief of cable strain Protection of the sensing face Switch mounted on mobile carrier
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled Any repetitive flexing of the
A proximity switch should not serve as
cable should be avoided
mechanical stop
2 Specifications are subject to change without notice (25.02.05)