T t y f p e r p e a g p Switching Power Supply Type SPD 10W DIN rail mounting Universal AC input full range Installation on DIN rail 7.5 or 15mm Short circuit protection Overload protection High efficiency LED indicator for DC power ON LED indication for DC low Power Ok output Internal input filter CE, TUV approved and cULus Listed Product Description Ordering Key SP D 24 10 1 B The Switching power supplies the installation is on a DIN rail Model SPD series are specially and compact dimensions and Mounting ( D = Din rail ) designed to be used in all performance are a must. Output voltage automation application where Output power Input Type Optional features Approvals Input type: 1= single phase Rheinland Product Safety Class I, Div 2 UL 1310 UL 60950-1 Output Performances INPUT OUTPUT OUTPUT OUTPUT EFF. EFF. EFF. MODEL NO. VOLTAGE WATTAGE VOLTAGE CURRENT (min.) (typ.) (avg.) Single Output Models SPD05 90~264 VAC 10 WATTS + 5 VDC 2000 mA 71% 83% 69% SPD12 90~264 VAC 10 WATTS + 12 VDC 840 mA 73% 86% 72% SPD24 90~264 VAC 10 WATTS + 15 VDC 670 mA 74% 87% 72% SPD48 90~264 VAC 10 WATTS + 24 VDC 420 mA 74% 87% 72% Output Data Line regulation 1% Rated continuous loading Load regulation 2% 5V Model 2A 5VDC/1.7A 5.75VDC Minimum load 0A 12V Model 0.84A 12VDC/0.72A 13.8VDC Turn on time (full resistive load) 1000ms 15V Model 0.67A 15VDC/0.58A 17.25VDC Vi nom, Io nom with 3500F 1500ms 24V Model 0.42A 24VDC/0.34A 28.8VDC Transient recovery time 2ms Reverse voltage Ripple and noise 50mVpp 5V Model VDC 7.5 Output voltage accuracy 1% 12V Model VDC 18 Temperature coefficient 0.03%/C 15V Model VDC 22 Hold up time 24V Model VDC 35 Vi= 115VAC 25ms Capacitor load 3500F Vi=230VAC 100ms Voltage rise time at full resistive load 500ms Voltage fall time (I nom Vi nom) 150ms max VI nom, Io nom with 3500F 150ms 0 10/01//19 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 1 t p r a r u o a v B e dSwitching Power Supply Type SPD 10W DIN rail mounting Input Data Rated input voltage 100 - 240VAC Power dissipation Voltage range 5V Model 4.0W AC 90 - 265VAC 12V Model 3.4W DC 120 - 375VDC 15V Model 3.3W Rated input current 24V Model 2.8W (Vi:115VAC, Io nom) Typ. 200mA Frequency range 47-63Hz Max. 300mA Leakage current Voltage range Input-Output 0.25mA Vi=115VAC 10A Input-FG 3.5mA Vi=230VAC 18A Controls and Protection Overload 110%~145% Over voltage protection 125 - 145% 1) Input fuse T25A/250VAC internal Internal surge voltage Output short circuit Hiccup mode protection Varistor 1) Fuse not replaceable by user General Data ( nominal line, full load, 25C) Ambient temperature -20C to +71C MTB Derating (>61C to +71C) 2.5%/C 5V Model 801000 Hours Ambient humidity 20 - 95% RH 12V Model 803000 Hours Storage -25C to +85C 15V Model 805000 Hours Protection degree IP20 24V Model 808000 Hours Cooling Free air convection Case material Plastic: PC, UL94-V0 Insulation voltage Pollution degree 2 Input-Output 3.000VAC/4242VDC min Altitude 2000 m Input-FG 1.500VAC/2121VDC min Dimensions LxWxD mm(inch) 90(3.60)x22.5(0.89)x114(4.49) Insulation resistance I/O 100M min ( 500VDC) Weight 120 g Norms and Standard Vibration resistance meet IEC 60068-2-6 CE EN 61000-6-3, EN 55022 (Mounting by rail: 10-500Hz, Class B, EN 61000-3-2, 2G, along X, Y, Z each Axis, EN 61000-3-3, 60 min for each Axis) EN 61000-6-2, Shock resistance meet IEC 60068-2-27 EN 55024, (15G,11ms, 3 Axis, 6 faces, EN 61000-4-2 Level 4, 3 times for each face) EN 61000-4-3 Level 3, UL/cUL UL508 listed, UL60950-1, EN 61000-4-4 Level 4, UL1310 Class 2 Power (only EN 61000-4-5 L-Level 3, 5V, 12V w/o Class 2) Reco L/N-FG Level 4, gnized, ISA 12.12.01 (Class EN 61000-4-6 Level 3, 1, Division 2, Groups A, B, C EN 61000-4-8 Level 4, and D) EN 61000-4-11, ENV 50204 Level 2, TUV EN 60950-1, CB scheme EN 61204-3 CCC Available upon request 2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 10/01//19