Low Profile Switching Power Supply Type SPM5BC DIN Rail Mounting Universal input 90~264 VAC Short circuit protection Internal input filter Charger for lead-acid batteries Battery polarity protection Installation on DIN Rail Product De scrip tion Ordering Key SPM 5 BC 12 30 X The SPM5BC battery voltage stabilized at a preset Series chargers are a range of value, even when not being Number of DIN module power supply units with charged. Made in plastic low Feature (BC=Battery Charger) charge lead-acid batteries profile housing they feature Output voltage optimising their performance Universal input 90~264VAC, Output power and duration. Based on integrated short circuit Optional features switch-mode technology, protection and battery they produce an output polarity protection. Approvals Output Performances INPUT OUTPUT OUTPUT OUTPUT EFF. EFF. MODEL NO. VOLTAGE POWER VOLTAGE CURRENT (min.) (typ.) Single Output Models 90~264 VAC 34 WATTS +13.6 VDC 2.5 A 84% 86% SPM5BC 1230 90~264 VAC 34 WATTS + 27.2 VDC 1.25 A 86% 88% SPM5BC 2430 SPM5BC 1260 90~264 VAC 61 WATTS +13.6 VDC 4.5 A 84% 86% SPM5BC 2460 90~264 VAC 68 WATTS + 27.2 VDC 2.5 A 86% 88% Output Data All specifications are at nominal values, full load, 25C unless otherwise noticed Line regulation 1% Voltage fall time (I nom, Vi nom) 150ms 0 Load regulation 1% Voltage rise time Vi nom, Io nom (full resistive load) 150ms Minimum load 0% Reverse voltage Turn on time (full resistive load) 12V Model 18VDC Vi nom, Io nom 1800ms 24V Model 35VDC Transient recovery time 2ms DC ON indicator Ripple and noise 100mVpp threshold at start up (Green LED) (Vi nom, Io nom) 12V Model 7-9VDC Output voltage accuracy 1% 24V Model 13-18VDC Temperature coefficient 0.03C Hold up time Vi= 115VAC 10ms Vi= 230VAC 30ms 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 29/02/2012Low Profile Switching Power Supply Type SPM5BC DIN Rail Mounting Input Data All specifications are at nominal values, full load, 25C unless otherwise noticed Rated input voltage Inom 100 - 240VAC Inrush current Vi= 115VAC 30A Voltage range Vi= 230VAC 60A AC IN 90 - 264VAC DC IN 120 - 375VDC Power dissipation (Vi : 230VAC, Io nom) 12V Model 5.5W Rated input current 24V Model 10.9W Vi: 115/230VAC Io nom 30W Model 680mA / 430mA Frequency range 47- 63Hz 60W Model 1230mA/780mA Leakage current Power dissipation Input-Output <0.25mA Vi: 230VAC, Io nom 30W Model 5.5W 60W Model 10.9W Controls and Protections All specifications are at nominal values, full load, 25C unless otherwise noticed Rated overload protection 105-110% Vi nom Internal surge voltage 1) protection IEC 61000-4-5 Varistor Input fuse T2A/250VAC internal Power Rdy Output short circuit Hiccup mode Rdy ON: Threshold at start up 12V Model 10-11 VDC Over voltage protection VDC 24V Model 17-19 VDC Min. Max. Rdy OFF: Threshold at start up 12V Model 7-8 VDC 12V Model 15 18 24V Model 13-15 VDC 24V Model 30 33 Battery polarity protection Yes 1) Fuse not replaceable by user General Data All specifications are at nominal values, full load, 25C unless otherwise noticed Ambient temperature -40C to + 51C MTBF (Bellcore issue 6 40C, GB) 30W 12V Model 668000 Hours Derating (+51C to +61C) 2.5%/C (see curve) 24V Model 688000 Hours Relative humidity 20 ~ 95%RH 60W 12V Model 568000 Hours Storage temperature -40C to + 85C 24V Model 588000 Hours Cooling Free air convection Case material Plastic Insulation voltage Altitude 4850m Input-Output 3.000VAC/4242VDC min Dimensions LxWxD mm (inch) 91(3.58) x 90(3.54) x 57(2.24) Insulation resistance I/O 100M min ( 500VDC) Weight 270g Switching Frequency 50 Khz min 100 Khz max Packing 330g Norms and Standards Vibration resistance meet IEC 60068-2-6 CE EN 61000-6-3, (10-500Hz, 2G, along X, Y, Z EN 55022 Class B, each Axis, 60 min for each EN 61000-3-2, Axis) EN 61000-3-3, EN 61000-6-2, Shock resistance meet IEC 60068-2-27 EN 55024, (15G, 11ms, 3 Axis, 6 faces, EN 61000-4-2 level 4, 3 times for each face) EN 61000-4-3 level 3 LVD EN 60950-1 EN 61000-4-4 level 4 EN 61000-4-5 L-N level 3 EN 61000-4-6 level 3 EN 61000-4-8 level 4 EN 61000-4-11, ENV 50204 Level 2 EN 61204-3 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 29/02/2012 2