dataT2000P.qk 6/17/01 11:14 PM Page 2 PID Controllers Temperature and Process Controls T2000P 1/16 DIN NEMA 4X Programable Process controller Autotune automatically sets PID parameters Multiple ramp/soak: Upto 31 programs, 126 segments Inputs: Thermocouple, RTD, Analog (0-20mA, 0-5VDC, 0-10VDC) Outputs: SSR voltage pulse, relay, Analog (0-20mA, 0-5VDC, 0-10VDC) 3rd relay output standard RS232 or RS485 MODBUS RTU protocol T2000P Three year warranty Product Description Ordering Key T2016P2 SR R X T 2 XX Programmable profiling temperature and process controller. Model Easy to view dual 4 digit display readout. Constructed in a Output rugged NEMA4X waterproof housing (front panel only) in 3rd output the popular 1/16 DIN size. Various inputs from temperature Not Used sensors to analog process inputs and various combinations Input of outputs including analog outputs and a 3rd relay output Communication standard. Not Used Type Selection Type Selection Model Outputs 3rd Output Not used Input Communication Not use T2016P2 SR: 6VDC pulse & 2A relay output R: 2A relay output X: not used T: TC-B,E,J,K,L,N,R,S,T & RTD X: None XX: not used RR: 2 - 2A relay outputs C: 4-20mA input 2: RS232 SS: 2 - 6VDC pulse outputs L: 0-5VDC input 4: RS485 CR: 4-2OmA & 2A relay output H: 0-10VDC input CS: 4-2OmA & 6VDC pulse output LR: 0-5VDC & 2A relay output LS: 0-5VDC & 6VDC pulse output HR: 0-10VDC & 2A relay output HS: 0-10VDC & 6VDC pulse output General Specifications Input Specifications (contd) Power supply 100-240VAC +/- 10%, 50-60Hz Thermocouple (contd) Display S 32 to 2912F (0 to 1600C) Upper display reading 4 digit high brightness green T -273 to 482F (-200 to 250C) LED 10mm high Standards IPTS/68/DIN 43710 Lower display 4 digit high brightness red CJC rejection 20:1 (0.05%C) typical LED 9mm high External resistance 100W maximum Output indicators LED output indicators (RTD) flashing SP1 square green Pt100/RTD (2 or 3 wire) -273 to 752F (-200 to 400C) LED output indicators Standards DIN 43760 (100W 0C/138.5W SP2 round red 100C Pt) Keypad 3 full travel elastomeric Bulb current 0.2 mA maximum pushbuttons Analog process input 0 to 50mV, +/- 0. 1% Approvals UL, CUL, CE 0-20mA, 4-20mA, +/- 0.1% 0-5V, +/- 0.1%, 0-10V, +/-0.1% Input Specifications Specifications for Both Thermocouples and RTDs Thermocouple Calibration accuracy +/- 0.25% maximum +/- 1C B 32 to 3275F (0 to 1800C) Sampling frequency Input 10Hz, CJC 2 sec. E 32 to 1112F (0 to 600C) Common mode rejection Negligible effect up to 140db, J 32 to 1472F (0 to 800C) 240V, 50-60Hz K -58 to 2192F (-50 to 1200C) Series mode rejection 60db, 50-60Hz L 32 to 1472F (0 to 800C) Temperature coefficient 150ppm/(C maximum) N -58 to 2192F (-50 to 1200C) Reference conditions 22C +/- 2C, rated voltage after R 32 to 2912F (0 to 1600C) 15 minutes settling time Specifications are subject to change without notice 1dataT2000P.qk 6/17/01 11:14 PM Page 3 T2000P Output Devices (maximum of two outputs) Housing Specifications (contd) SSd (solid state relay driver) 6 VDC, 20mA Installations Categories II and III non-isolated Pollution Degree II Relay Form A SPST, 2A/250VAC Protection NEMA 4X (IP66) resistive load EMC emission EN50081-1, FCC Rules 15 Analog Output 4-20mA 500 max subpart J Class A +/- 0. 1% full scale typical EMC immunity EN50082-2 0-5Vdc 10mA (500 min) Ambient 32 to 122F (0 to 50C) +/- 0.1% full scale typical Moldings Flame retardant polycarbonate 0-10Vdc 10mA (1K min) Instrument body +/- 0.1% full scale typical Model T2016P2 1.76 x 1.76 (44.8 x 44.8mm) Overall length 4.57 (116mm) Weight Housing Specifications T2016P2 6.4 ounces Environmental Dimensions (front fascia) Model T2016P2 2.0 x 2.0 (51 x 51mm) Safety UL873, EN61010, CSA 22.2 No. includes gasket 1010.1-92 Sleeve length 4.2 (106.7mm) Humidity Maximum 95% includes gasket Altitude Up to 2000m Programmer Functionality Memory Allocation Table Function Memory Usage Up to 31 programs (profiles) Ramp 4 Bytes Up to 126 segments Ramp with Holdback 5 Bytes Unlimited use of event outputs via the 2nd and 3rd outputs Soak 2 Bytes Copy/Paste/Edit/Delete functions to simplify program Step 3 Bytes building Loops (1 -3) 1 Byte Call another program as a sub-program segment Loop (4+) 2 Bytes Call 1 Byte Up to 999 program loop cycles, or continuous loop cycling Event Output 1 Byte Hold back function, to ensure the next segment is not Program Header 1 Byte started until the last segment reaches the set-point 3 power fall recovery options, (Hold, Continue or Reset) Examples Example 1 Example 2 Max. capacity 351 (349 Bytes) One (340 Bytes) 4 programs Front panel interrogation of the program position Bytes, 126 segments program of 116 of 28 segments Memory usage Indication during programming. per program, 31 segments (58 (14 ramps, 14 (note: program capacity is a memory function and different programs ramps, 58 soaks) soaks) types of segment use more/less memory). Set-point Segment 1 Segment 2 Segment 3 Segment 5 Segment 7 Segment 8 Segment 10 Profile of a single program RAMP SOAK RAMP RAMP SOAK RAMP SOAK CONTIN- Set-point UOUS Segment 1 Segment 2 Segment 4 Segment 5 Segment 6 RAMP SOAK SOAK RAMP SOAK Segment 7 EVENT OUTPUT Time Segment 3 Segment 4 Segment 6 Segment 9 STEP Program LooP Program CALL E.oP Event Output from 1 to 999 cycles to call another program e.g. Trigger alarm on SP2 Time e.g. loop for 25 cycles e.g. Call Prog 5 then go to 7 Dimensions Wiring Diagram T2016P Series T2016P Series Analog Heater power controller 17 18 19 20 21 22 23 24 (+) () User configurable alarms 4-20mA INPUT () (+) LN 1 2 3 4 56 78 4-20mA 4.57 Transducer 2.0 (116.2mm) Line (51.0mm) F1 4.2 Mains Neutral includes gasket F2 (106.7mm) S1 with gasket fitted 2.0 (51.0mm) includes gasket 1.76 (44.8mm)