dataT2000.qk 3/8/01 17:29 Page 2 PID Controllers Temperature Controls T2000 1/16 DIN and 1/32 DIN NEMA 4X protection Autotune automatically sets PID parameters Single ramp/soak program Heat-cool operation AC or DC power supply Inputs: Thermocouple, RTD, 0-50mV Two outputs: SSR voltage pulse/relay Five alarm modes RS232 or RS485 (retrofittable) MODBUS RTU protocol T2000 Three year warranty Product Description Ordering Key T20 16 1 SR 2 A Microprocessor based controller for temperature Model measurements in C or F. Easy to view single or dual Size 4 digit display readout. Constructed in a rugged Display NEMA4X waterproof housing in the popular 1/32 or Outputs 1/16 DIN size. 100-240VAC or 12-24VDC supply voltage. Communication Universal inputs and various combinations of output Power Supply types are also standard features. Type Selection Model Size Display Outputs Communication Power Supply T20 16: 1/16 DIN 1: Single SR: 5VDC Pulse X: None A: 100-240VAC 32: 1/32 DIN Display and 1A 2: RS232 B: 12-24VAC/DC 2: Dual Display Relay 4: RS485 (Only single (1/16 DIN Outputs display units only) RR: 2A and 1A with SR and Relay Output SS outputs) SS: Two 5VDC Pulse Outputs General Specifications Input Specifications (contd) Power supply 100-240VAC +/- 10%, 50-60Hz Thermocouple (contd) 12-24VAC/DC +/- 20%, S 32 to 2912F (0 to 1600C) 50-60Hz T -273 to 482F (-200 to 250C) Display Standards IPTS/68/DIN 43710 Upper display reading 4 digit high brightness green CJC rejection 20:1 (0.05%C) typical LED 10mm high External resistance 100W maximum Lower display (T20162) 4 digit high brightness red (RTD) LED 9mm high Pt100/RTD-2 (2 wire) -273 to 752F (-200 to 400C) Output indicators LED output indicators Standards DIN 43760 (100W 0C/138.5W flashing SP1 square green 100C Pt) LED output indicators Bulb current 0.2 mA maximum SP2 round red Linear process input Keypad 3 full travel elastomeric mV 0 to 50 mV (0 to 20 mV, 4 to 20 pushbuttons mV) Approvals UL, CE Specifications for Both Thermocouples and RTDs Calibration accuracy +/- 0.25% maximum +/- 1C Input Specifications Sampling frequency Input 10Hz, CJC 2 sec. Thermocouple Common mode rejection Negligible effect up to 140db, B 32 to 3275F (0 to 1800C) 240V, 50-60Hz E 32 to 1112F (0 to 600C) Series mode rejection 60db, 50-60Hz J 32 to 1472F (0 to 800C) Temperature coefficient 150ppm/(C maximum) K -58 to 2192F (-50 to 1200C) Reference conditions 22C +/- 2C, rated voltage after L 32 to 1472F (0 to 800C) 15 minutes settling time N -58 to 2192F (-50 to 1200C) R 32 to 2912F (0 to 1600C) Specifications are subject to change without notice 1dataT2000.qk 3/8/01 17:29 Page 3 T2000 Output Devices (maximum of two outputs) Housing Specifications (contd) SSd (solid state relay driver) 5 VDC +/- 15%, 15ma, Instrument body non-isolated Model T2016 1.76 x 1.76 (44.8 x 44.8mm) Relay Form A SPST, 2A/250VAC Model T2032 1.76 x 0.87 (44.8 x 22.0mm) resistive load Overall length 4.57 (116mm) Second Relay Form A SPST, 1A/250VAC Weight resistive load T20161 4.2 ounces T20162 4.6 ounces Housing Specifications T2032 3.9 ounces Dimensions (front fascia) Environmental Model T2016 2.0 x 2.0 (51 x 51mm) Safety UL873, EN61010, CSA 22.2 Text includes gasket No. 1010.1-92 Model T2032 2.0 x 1.12 (51 x 28.5mm) Humidity Maximum 80% includes gasket Altitude Up to 2000m Sleeve length 4.2 (106.7mm) Installations Categories II and III includes gasket Pollution Degree II Protection NEMA 4X (IP66) EMC emission EN50081-1, FCC Rules 15 subpart J Class A EMC immunity EN50082-2 Ambient 32 to 122F (0 to 50C) Moldings Flame retardant polycarbonate Dimensions Wiring Diagram T2016 Series T2016 Series (T20162 shown) Comms option 1.76 (when fitted) (44.8mm) 9 1011 12 131415 16 + + 5Vdc 15mA LN 1 2 345 6 7 8 Sensor Output Output Supply SP1 SP2 2.0 4.57 Sensor (51.0mm) (116.2mm) Open in alarm includes gasket S1 4.2 state + Load SSR (106.7mm) with gasket fitted Line F2 F1 Neutral T2032 Series T2032 Series 1.76 Comms option (44.8mm) (when fitted) 9 1011 12 131415 16 + + 5Vdc 15mA LN 1 23 4 567 8 Sensor Output Output Supply 4.57 SP1 SP2 2.0 Sensor (116.2mm) (51.0mm) Open in alarm S1 includes gasket 4.2 state Load + SSR (106.7mm) with gasket fitted Line F2 F1 Neutral Specifications are subject to change without notice 2 1.12 2.0 (28.5mm) (51.0mm) includes gasket includes gasket .87 1.76 (22.0mm) (44.8mm)