Energy Management Power Analyzer Type WM14-DIN Basic Version Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5 F.S. (current/voltage) Power analyzer Display of instantaneous variables: 3x3 digit Display of energies: 8+1 digit System variables and phase measurements: W, W , dmd var, VA, VA , PF, V, A, An, A , Hz dmd dmd A , A , W indication max dmd max dmd max Energy measurements: kWh and kvarh Hour counter (5+2 DGT) TRMS meas. of distorted sine waves (voltages/currents) Power supply: 24V, 48V, 115V, 230V, 50-60Hz 18 to 60VDC Protection degree (front): IP40 Optional dual pulse output Front dimensions: 107.8x90mm Alarms (visual only) V , An LN Optional RS422/485 serial port Optional galvanically insulated measuring inputs Product Description How to order WM14-DIN AV5 3 D PGX Model 3-phase power analyzer with ing, (front) protection degree built-in programming key- Range code IP40, and optional RS485 pad. Particularly recom- serial port or dual pulse out- System mended for displaying the put. Parameters pro- Power supply main electrical variables. grammable by means of Option Housing for DIN-rail mount- CptBSoft. How to order CptBSoft CptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables. Type Selection Range codes System Power supply Options AV5: 380/660V /5(6)AAC 3 : 1-2-3-phase, L-L A: 24VAC X: None balanced/unbalanced VL-N: 185 V to 460 V S: RS485 port -15+10%, 50-60Hz load,with or without VL-L: 320 V to 800 V SG: RS485+galvanic insu- B: 48VAC neutral AV6: 120/208V /5(6)AAC lated measurig inputs L-L -15+10%, 50-60Hz PG: Dual pulse output + VL-N: 45 V to 145 V C: 115VAC galvanically insulated VL-L: 78 V to 250 V -15+10%, 50-60Hz measuring inputs. Phase current: 0.03A to 6A D: 230VAC Neutral current: 0.09 to 6A -15+10%, 50-60Hz 3: 18 to 60VDC (not available in case of SG or PG options) Input specifications Rated inputs Reactive energy X-S option Class 3 (start up I: 30mA) Current X-S options 3 (non insulated each other) Active energy SG-PG opt. Class 1 (start up I: 30mA) Current SG-PG options 3 (insulated each other) Reactive energy SG-PG opt. Class 2 (start up I: 30mA) Voltage 4 Frequency 0.1Hz (48 to 62Hz) Accuracy (display, RS485) with CT=1 and VT=1 AV5: Additional errors ( 25C 5C, R.H. 60%) 1150W-VA-var, FS:230VLN, Humidity 0.3% FS, 60% to 90% RH 400VLL AV6: 285W-VA-var, Temperature drift 200ppm/C FS:57VLN, 100VLL Sampling rate 1400 samples/s 50Hz Current 0.25 to 6A: (0.5% FS +1DGT) 1700 samples/s 60Hz 0.03A to 0.25A: (0.5%FS+7DGT) Neutral current 0.25 to 6A: (1.5% FS +1DGT) Display refresh time 700ms 0.09A to 0.25A: (0.5%FS+7DGT) Display Phase-phase voltage (1.5% FS +1 DGT) Type LED, 9mm Read-out for instant. var. 3x3 DGT Phase-neutral voltage (0.5% FS + 1 DGT) Read-out for energies 3+3+3 DGT (max indication: Active and Apparent power, 0.25 to 6A: (1% FS +1DGT) 999 999 99.9) 0.03A to 0.25A: (1% FS+5DGT) Read-out for hour counter 1+3+3 DGT (max. indication: Reactive power 0.25 to 6A: (2% FS +1DGT) 9 999 9.99) 0.03A to 0.25A: (2% FS+5DGT) Active energy X-S option Class 2 (start up I: 30mA) Specifications are subject to change without notice WM14 DIN B DS ENG 140317 1WM14-DIN Input specifications (cont.) Measurements Current, voltage, power, Input impedance (PG-SG options) power factor, frequency, 380/660V (AV5) 1 mW 1% L-L energy, TRmS measurement 120/208V (AV6) 1 mW 1% L-L of distorted waves. Current 0.02 Coupling type Direct Crest factor < 3, max 10A peak Frequency 48 to 62 Hz Input impedance (X-S options) Overload protection Continuos voltage/current 1.2 F.S. 380/660V (AV5) 1 mW 5% L-L For 500ms: voltge/current 2 Un/36A 120/208V (AV6) 453 KW 5% L-L Current 0.02 RS485 Serial Port Specifications RS422/RS485 (on request) Data (bidirectional) Type multidrop Dynamic (reading only) System, phase variables and bidirectional (static and energies dynamic variables) Static (writing only) All configuration parameters Connections 2 or 4 wires, max. distance Data format 1 bit di start , 8 data bit, 1200m, termination directly no parity, 1 stop bit on the instrument Baud-rate 9600 bit/s Addresses 1 to 255, key-pad selectable Protocol mODBUS/JBUS CptBSoft software: parameter programming and reading data CptBSoft multi language software to Working mode Two different working program the working modes can be selected: parameters of the power - management of a local analyzer and to read the RS485 network energies and the - management of instantaneous variables. communication from a single The program runs under instrument to PC (RS232) Windows 95/98/98SE/2000/ Data access By means of RS485 NT/XP. serial port. Dual pulse output Digital outputs (on request) Pulse duration 100ms <120ms (ON) Pulse outputs 100ms (OFF) Number of outputs 2 (one for kWh one for kvarh) According to EN622053-31 Number of pulses From 0.01 to 999 in Insulation By means of relays, compliance with the 4000 V outputs to RmS following formula: measuring inputs, Psys max (kW or 4000 V output to RmS kvar)*pulses (pulses/kWh supply input. or kvarh) <14400 Insulation between the two Output type Relay outputs: 1000V RmS min current: .05A 250VAC/30VDC max current: A 250VAC/30VDC 5 Electrical life: min 2*10 cycles 6 mechanical life: 5*10 cycles 2 Specifications are subject to change without notice WM14 DIN B DS ENG 140317