V15 CFM05 SERIES 5 WATT OPEN FRAME AC-DC MODULES Features * Universal Input Range 85~264VAC * Efficiency to 79% * Meets EN55032 Class B * Continuous Short Circuit Protection * Low Leakage Current 0.25mA Max. * PCB Mountable OUTPUT RIPPLE VOLTAGE LINE LOAD % EFF. OUTPUT CURRENT(A) (mVp-p) ACCURACY REGULATION REGULATION (Typ.) MODEL VOLTAGE MIN. MAX. NOTE 1 NOTE 2 NOTE 3 NOTE 4 NOTE 5 CFM05S033 3.3V 0A 1.25A 50mV 69% 1% 0.5% 1% CFM05S050 5.0V 0A 1.0A 50mV 73% 1% 0.5% 1% CFM05S090 9.0V 0A 0.55A 90mV 77% 1% 0.5% 1% CFM05S120 12.0V 0A 0.42A 120mV 77% 1% 0.5% 1% CFM05S150 15.0V 0A 0.33A 150mV 78% 1% 0.5% 1% CFM05S180 18.0V 0A 0.28A 180mV 79% 1% 0.5% 1% CFM05S240 24.0V 0A 0.23A 240mV 76% 1% 0.5% 1% Specifications are subject to change without notice. 1 V15 Specifications CFM05S Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 85~264Vac 75% Frequency ...... 47 to 63Hz Inrush Current ..................... 40A max. 240Vac 50% Conducted EMI .. CISPR/FCC Class B 20LFM(Natural Convection) Leakage Current . 0.25mA max. 25% OUTPUT SPECIFICATIONS: 0% Holdup Time 8mS typ. 115Vac 0 10 20 30 40 50 60 70 80 90 o Short Circuit Protection Continuous (Auto Recovery) Ambient Temperature( C) Over Voltage Protection ................... TVS Component to Clamp Temperature Coefficient ............................ 0.05%/ SAFETY AND EMC: Emission and Immunity .... EN55032 Class B, EN61000-6-3 GENERAL SPECIFICATIONS: Isolation ... Input to output = 4,242VDC EN61000-3-2, EN61000-3-3, EN55024 Operating Temperature ............................ 0~ 85 (see derating curve) EN61204-3, EN61000-6-1 Storage Temperature .................. -20~85 Safety ... IEC60950-1, EN60950-1, UL60950-1 Humidity ...................................................... 93% RH max. Non condensing NOTE: Cooling .... Natural Convection 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Switching Frequency .................. 60KHz Typical Ripple & Noise measuring 20MHz BW. MTBF .. MIL-HDBK-217F, GB, at 25/115VAC 200Khrs min. 2. Voltage accuracy is set at 100% rated load and 25 Ta. Altitude ....... 2000m 3. Line regulation is measured from 100Vac to 240Vac with full load. Dimensions ... 2.165x1.378x0.827inches (55.00x35.00x21.00mm) 4. Load regulation is measured from 10% to 100% full load. Weight ... 35g (0.08 Pounds) 5. Typical efficiency at 230VAC and full load at 25. CFM05 Series All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 -Vo ACN +Vo ACL 0.158 4.01 VR 2.008 51.01 2.165 55.00 0.040 1.02 0.070 1.78 1.850 47.00 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 1.378 35.00 0.886 22.50 0.173 4.40 0.146 3.70 0.063 1.60 0.491 12.47 0.102 2.60 1.279 32.48 0.827 21.00 Rated Load(%)