V15 CFM150M SERIES 150W MEDICAL AND ITE OPEN FRAME AC-DC MODULES WITH PFC Features * Universal Input Range 90 ~ 264VAC * Medical and ITE Safeties * 3x 5 Compact Size * Less than 1 U high 1.05 * Industry Standard Pin Out * Active PFC Meets EN61000-3-2 * High Efficiency up to 93% * Meets CISPR/FCC Class B * Remote Voltage Sense * Over Voltage Protection * Continuous Short Circuit Protection * No load Power Consumption<0.5W * Meets 2MOPP RIPPLE & VOLTAGE LINE LOAD % EFF. OUTPUT MAX. MIN. MODEL NOISE ACCURACY REGULATION REGULATION (Typ.) VOLTAGE LOAD LOAD NOTE 1 NOTE 2 NOTE 3 NOTE 4 NOTE 5 CFM150M120 12 V 12.5 A 0A 1% 1% 0.5% 1% 90% CFM150M240 24 V 6.25 A 0A 1% 1% 0.5% 1% 92% CFM150M360 36 V 4.17 A 0A 1% 1% 0.5% 1% 92% CFM150M480 48 V 3.13 A 0A 1% 1% 0.5% 1% 93% Specifications are subject to change without notice. 1 V15 Specifications CFM150M Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac 80% Frequency ...... 47 to 63Hz Inrush Current .................. 110A max. 240Vac 60% Leakage Current .... 300uA max. 20LFM(Natural Conv ection) 40% OUTPUT SPECIFICATIONS: Hold-up Time ... 16ms typ. 20% Short Circuit Protection .. Hiccup mode(Auto Recovery) 0% Adjustment Range on Vout . 5% -20 -10 0 10 20 30 40 50 60 70 Over Voltage Protection Recycle AC input to restart Temperature Coefficient .............................. 0.05%/ o Ambient Temperature( C) GENERAL SPECIFICATIONS: Isolation . Input to output = 5,656VDC NOTE: Operating Temperature .......................... -20~ 70 (see Derating Curve) 1. Add a 0.1uF ceramic capacitor and 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. Storage Temperature .................. -20 ~ 85 Humidity ....................................................... 93% RH max. Non condensing 2. Voltage accuracy is set at 100% rated load and 25 Ta. Cooling . Natural Convection 3. Line regulation is measured from high line to low line with full load. Switching Frequency ............................ 90KHz Typical. 4. Load regulation is measured from full to 10% load. MTBF . MIL-HDBK-217F, GB, 25/115VAC 100Khrs min. 5. Typical efficiency at 230VAC and full load at 25. Altitude ....... 3000m 6. Standard input and output connectors wafer with LONG CHU P3060 Dimensions .. 5.000x3.000x1.050inches (127.00x76.20x26.67mm) series and mate with MOLEX housing 09-50-1031 and 09-50-1081 or Weight ... 270g (0.6Pounds) equivalent. 7. DC output pin 1, 2, 3, 4: Vout (-), DC output pin 5, 6, 7, 8: Vout (+). SAFETY AND EMC: Emission and Immunity (Ed. 4.0) .. EN55011, EN55032 Class B FCC CFR 47 Part 15, EN61000-3-2, 3, IEC61000-4-2, 3, 4, 5, 6, 8, 11 Safety (Ed. 3.1) . IEC60601-1:2005+A1:2012 IEC60950-1:2005+A1:2009+A2:2013, EN60601-1:2006+A11:2011+A1+A12 nd EN60950-1:2006+A11+A1+A12:2011+A2:2013, UL ANSI/AAMI ES60601-1:2005, UL60950-1, 2 Editon CFM150M Series All Dimensions are in inches mm Tolerances Inchesx.xxx=0.02 Millimetersx.xx=0.5 5.000(127.00) 4.546(115.48) 0.224(5.70) LED 1 2 3 4 5 6 7 8 RS- ACL RS+ VR ACN Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 Rated Load(%) 0.118(3.00)max 0.063(1.60) 1.050(26.67)max 0.224(5.70) 2.555(64.90) 3.000(76.20)