V14 CFM40D/T SERIES 40W DUAL/TRIPLE OUTPUT AC-DC OPEN FRAME Features * Universal Input Range 90~264Vac * 2 x 4 Size * Industry-Standard Pin Out * Efficiency to 81% * Short Circuit Protection * Meets EN61204-3 Class B and CISPR/FCC Class B * Approved IEC/EN/UL62368-1 OUTPUT CURRENT(A) OUTPUT RIPPLE VOLTAGE LINE LOAD O/P Power (%) EFF. MODEL VOLTAGE (mVp-p) ACCURACY Reg. Reg. Max. (Typ.) Min. Rated Max. 5V(V1) 0.4 3.2 5.0 50 3% 1% 3% CFM40D-01 40.0W 80% 12V(V2) 0.2 2.0 2.5 120 4% 2% 5% 5V(V1) 0.4 3.2 5.0 50 3% 1% 3% CFM40D-02 40.0W 81% 24V(V2) 0.2 1.0 1.5 240 4% 2% 5% 5V(V1) 0.4 3.0 5.0 50 3% 1% 3% 12V(V2) CFM40T-01 0.2 2.0 2.5 120 4% 2% 5% 40.5W 78% -5V(V3) 0 0.3 0.5 50 3% 1% 1% 5V(V1) 0.4 3.0 5.0 50 3% 1% 3% CFM40T-02 12V(V2) 0.2 2.0 2.5 120 4% 2% 5% 42.6W 78% 0 0.3 0.5 120 3% 1% 1% -12V(V3) 5V(V1) 0.4 3.0 5.0 50 3% 1% 3% 15V(V2) CFM40T-03 0.2 1.5 2.3 150 4% 2% 5% 42.0W 78% -15V(V3) 0 0.3 0.5 150 3% 1% 1% 5V(V1) 0.4 3.0 5.0 50 3% 1% 3% CFM40T-04 24V(V2) 0.2 1.0 1.5 240 4% 2% 5% 42.6W 78% 0 0.3 0.5 120 3% 1% 1% -12V(V3) 5V(V1) 0.4 3.0 5.0 50 3% 1% 3% 24V(V2) CFM40T-05 0.2 1.0 1.5 240 4% 2% 5% 40.5W 78% -5V(V3) 0 0.3 0.5 50 3% 1% 1% 5V(V1) 0.4 3.0 5.0 50 3% 1% 3% CFM40T-06 24V(V2) 0.2 1.0 1.5 240 4% 2% 5% 42.6W 78% 0 0.3 0.5 120 3% 1% 1% 12V(V3) 3.3V(V1) 0.4 5.0 7.0 100 3% 1% 3% 5V(V2) CFM40T-07 0.2 2.0 3.5 100 4% 3% 5% 30.0W 71% -12V(V3) 0 0.3 0.5 120 3% 1% 1% 1 V14 Specifications CFM40D/T Series Derating Curve INPUT SPECIFICATIONS: Open Frame versions: Voltage ....................................................... 90~264Vac CFM40D-01, 40D-02, 40T-01, 40T-02, 40T-03, 40T-04, 40T-05, 120~370Vdc 40T-06 Frequency ...... 47 to 63Hz 100% Inrush Current ...... Cold Start 25 .................. 60A max. 240Vac Input Current .................................... 1A max. (RMS) 115Vac 75% Leakage Current ... 3.5mA max. 50% 20LFM (Natural Conv ection) OUTPUT SPECIFICATIONS: 25% Rated Power for Convection Cooling .... 40W (CFM40T-07, 30W) 0% Maximum Power with 30 CFM Forced Air .. 50W (CFM40T-07, 40W) 0 10 20 30 40 50 60 70 Holdup Time 20ms typ. 115Vac o Ambient Temperature ( C) Short Circuit .. Hiccup Mode (Auto Recover) Over Voltage Protection CFM40D/T ..... 6V on V1(5V) 16V/20V/30V on V2(12V/15V/24V) CFM40T-07 Over Voltage Protection CFM40T-07 .. 6V on V1 (3.3V), 9V on V2 (5V) Temperature Coefficient ............................... 0.05%/ 100% GENERAL SPECIFICATIONS: 75% Isolation Input to output = 4,242VDC 50% Operating Temperature ............................. 0 ~ 70 (see Derating Curve) 20LFM (Natural Conv ection) Storage Temperature ................. -20 ~ 85 25% Humidity .................................................... 93% RH max. Non-Condensing 0% Cooling .. Natural Convection 0 10 20 30 40 50 60 70 Switching Frequency ... 62.5KHz Typical o Ambient Temperature ( C) MTBF MIL-HDBK-217F, GB, 25/115VAC 200Khrs min. Altitude ... 2000m Dimensions Covered versions: CFM40D/T-XX-CA Open Frame Versions ... 4.000x2.000x1.224Inches(101.60x50.80x31.10mm) CFM40D-01, 40D-02, 40T-01, 40T-02, 40T-03, 40T-04, 40T-05, Covered Versions . 4.606x2.480x1.575inches(117.00x63.00x40.00mm) 40T-06 Weight .. Open Frame versions 180g (0.40 Pounds) 100% Covered versions . 220g (0.49 Pounds) SAFETY AND EMC: 75% Emission and Immunity ...... EN55032 Class B, FCC Part 15 Class B 50% EN61000-6-3, EN61000-3-2, EN61000-3-3 20LFM (Natural Convection) EN55024, EN61204-3, EN61000-6-1 25% Safety .. IEC/EN/UL62368-1, IEC/EN/UL60950-1 NOTE: 0% 1. Voltage accuracy is set at full load and 25 Ta. 0 10 20 30 40 50 60 o 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ambient Temperature ( C) ripple&noise measuring 20MHz BW. 3. Line regulation is measured from 100Vac to 240Vac with full load. CFM40T-07 4. Load regulation is measured from 60% to 100% full load and from 60% 100% to 20% full load (60% 40% full load) 75% 5. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 50% 6. Output connector mates with Molex housing 09-50-3061 and Molex 20LFM (Natural Convection) 2878 series crimp terminal. 25% 7. Safety approvals do not apply to the covered versions, only to the open-frame versions. 0% 0 10 20 30 40 50 60 o Ambient Temperature ( C) 2 Rated Load (%) Rated Load (%) Rated Load (%) Rated Load (%)