CFM500S SERIES 500 WATT AC-DC POWER SUPPLY WITH PFC Features Universal Input Range 80~264Vac High Efficiency up to 94.5% 3x 5 Compact Size Class I No Load Power Consumption<0.5W Approval IEC/EN/UL 62368-1 Approval EN 55032, 47 CFR FCC Part 15 Active PFC Meets EN 61000-3-2 Meets IEC/EN 60335-1 3 High Power Density up to 21.64W/Inch 390W Natural, 470 ~ 500W Conduction Convection Over Temperature Protection PS On/Off Remote Control Power Good & Power Fail Signal +5V Stand-by, 12V Fan Output Low Inrush Current OUTPUT CURRENT VOLTAGE RIPPLE LINE LOAD NOTE1 MODEL OUTPUT VOLTAGE %EFF. ACCURACY &NOISE REGULATION REGULATION NUMBER VOLTAGE Without FAN ADJ. RANCE (Typ.) With FAN NOTE2 NOTE3 NOTE4 NOTE5 COVER OPEN CFM500S120 12 V 41.67A 27.5A 25A 1% 120mV 11.4~12.6 V 0.5% 1% 92.5% CFM500S180 18 V 27.78A 18.33A 16.67A 1% 150mV 17.1~18.9 V 0.5% 1% 93.5% CFM500S240 24 V 20.83A 17.08A 15.83A 1% 150mV 22.8~25.2 V 0.5% 1% 94.5% CFM500S360 36 V 13.89A 11.39A 10.56A 1% 200mV 34.2~37.8 V 0.5% 1% 94.5% CFM500S480 48 V 10.42A 8.54A 7.92A 1% 250mV 45.6~50.4 V 0.5% 1% 94.5% Stand-by Output Voltage All +5V 1A 3% 100mV --- 1% 5% --- Fan Output Voltage All +12V 0.5A (NOTE 6) --- --- --- --- --- --- Note: 1. Forced air convection with 21CFM Fan. 2. Voltage accuracy is set at 100% full load and 25 Ta. 3. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for ripple & noise measuring 20MHz BW. 4. Line regulation is measured from high line to low line with 100% full load. 5. Load regulation is measured from 10% to 100% full load. 6. Fan output can only operate normal when the stand-by output is above 0.5A. PART NUMBER Series Number of Outputs Nominal Output Voltage Type Output Terminal CFM500 X XXX X (Option) -X(Option) 120 12 V 180 18V None None With Baseplate Vertical CFM500 SSi ngle 240 24V C With Cover RH orizontal 360 36V 480 48V Part Number Example: CFM500S120: With Baseplate, 500W, 12Vdc Output, Vertical Type Terminal CFM500S120C: With Cover, 500W, 12Vdc Output, Vertical Type Terminal CFM500S120-R: With Baseplate, 500W, 12Vdc Output, Horizontal Type Terminal CFM500S120C-R: With Cover, 500W, 12Vdc Output, Horizontal Type Terminal www.cincon.com 1 REVISION: V12 CFM500S Series TECHNICAL SPECIFICATIONS (All specifications are typical at nominal input, full load at 25 unless otherwise noted.) ABSOLUTE MAXIMUM RATINGS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Input Voltage Safety approvals only to the AC input All 80 264 V ac Operating Case Temperature See Derating Curve All -40 85 Storage Temperature All -40 85 Operating Altitude All 5000 m INPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Operating Voltage Range All 100 240 V ac Input Frequency Range All 47 63 Hz Maximum Input Current 100% Full Load, V =100V All 6 A in ac Power Factor V =230V All 0.97 in ac Leakage Current All 0.3 mA Inrush Current V =240V , Cold start at 25 All 8.5 A in ac OUTPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units CFM500S120 11.88 12 12.12 CFM500S180 17.82 18 18.18 Output Voltage Set Point V =Nominal V , I =Io max., T =25. CFM500S240 23.76 24 24.24 V in in o c dc CFM500S360 35.64 36 36.36 CFM500S480 47.52 48 48.48 CFM500S120 41.67 CFM500S180 27.78 Operating Output Current Range Vin=80V ~264V See Derating Curve CFM500S240 20.83 A ac ac, CFM500S360 13.89 CFM500S480 10.42 Holdup Time V =115V All 16 ms in ac Output Voltage Regulation Load Regulation 10% to 100% full load All 1.0 % Line Regulation V =High line to low line All 0.5 % in CFM500S120 16 CFM500S180 30 Over Voltage Protection Latch off (AC recycle to reset) CFM500S240 35 V dc CFM500S360 50 CFM500S480 63 Over Current Protection Auto recovery All 120 190 % Short Circuit Protection Auto recovery All Over Temperature Protection Auto recovery All CFM500S120 120 1. Add a 0.1uF ceramic capacitor and a CFM500S180 150 10uF aluminum electrolytic capacitor to output Output Ripple and Noise CFM500S240 150 mV 2. Oscilloscope is 20MHz bandwidth CFM500S360 200 3. Ambient temperature=25 CFM500S480 250 www.cincon.com 2 REVISION: V12