V15 CFM60T SERIES 60W TRIPLE OUTPUT AC-DC MODULES Features * Universal Input: 90~264Vac * 2 x 4 Size * Industry-Standard Pin Out * Efficiency to 83% * Short Circuit Protection * Meets EN61204-3 Class B and CISPR/FCC Class B * Approved IEC/EN/UL62368-1 Output Current(A) Output Ripple Voltage Line Load O/P Power % EFF. MODEL Voltage (mVp-p) Accuracy Reg. Reg. Max. (Typ.) Min. Rated Max. V1=5V 0A 4.0A 5.0A 50mV 2% 1% 4% CFM60T-01 V2=12V 0A 3.0A 3.7A 120mV 5% 1% 3% 62W 83% V3=-12V 0A 0.5A 0.65A 120mV 5% 1% 5% V1=5V 0A 4.0A 5.0A 50mV 2% 1% 4% CFM60T-02 V2=15V 0A 2.5A 3.1A 150mV 4% 1% 3% 62W 83% V3=-15V 0A 0.3A 0.5A 150mV 5% 1% 5% V1=5V 0A 4.0A 5.0A 50mV 2% 1% 4% CFM60T-03 V2=24V 0A 1.5A 1.8A 240mV 3% 1% 3% 62W 83% V3=-12V 0A 0.5A 0.6A 120mV 5% 1% 5% V1=3.3V 0A 6.0A 7.5A 50mV 4% 1% 5% CFM60T-04 V2=5V 0A 3.0A 3.7A 50mV 5% 1% 4% 40.8W 78% V3=-12V 0A 0.5A 0.65A 120mV 5% 2% 5% 1 V15 Specifications CFM60T Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac 120~370Vdc 75% Frequency ...... 47 to 63Hz Inrush Current Cold Start 25 ............... 50A max. 240Vac 20LFM (Natural Convection) 50% Leakage Current ... 3.5mA max. OUTPUT SPECIFICATIONS: 25% Holdup Time 8ms typ. 115Vac Short Circuit .. Hiccup Mode (Auto Recover) 0% Over Voltage Protection ........ 6V/7V on V1(3.3V/5V) 0 10 20 30 40 50 60 15V/18V/28V on V2(12V/15V/24V) o Ambient Temperature ( C) Temperature Coefficient ............................... 0.05%/ GENERAL SPECIFICATIONS: NOTE: Isolation . Input to output = 4,242VDC 1. Voltage accuracy is set of 60% rated load. Operating Temperature ........................... 0 ~ 60 (see Derating Curve) 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. Storage Temperature ................. -20 ~ 85 Humidity .................................................... 93% RH max. Non-Condensing 3. Line regulation is measured from 103Vac~127Vac & 207Vac~253Vac with Cooling .. Natural Convection rated load. Switching Frequency ... 65KHz Typical 4. Load regulation is defined by changing 40% of measured output load MTBF MIL-HDBK-217F, GB, 25/115VAC . 200Khrs min. from 60% rated load at other outputs set to 60% rated load. Altitude .... 2000m 5. Input connector mates with Molex housing 09-50-3031 and Molex Dimensions . 4.000x2.000x1.260Inches (101.60x50.80x32.00mm) 2878 series crimp terminal. Weight ... 170g (0.37 Pounds) 6. Output connector mates with Molex housing 09-50-3061 and Molex SAFETY AND EMC: 2878 series crimp terminal. Emission and Immunity .... EN55032 Class B, FCC Part 15 Class B EN61000-3-2, EN61000-3-3, EN55024 Safety . IEC/EN/UL62368-1, IEC/EN/UL60950-1 Mechanical Specification All Dimensions in Inches mm Tolerance Inches:x.xxx0.02 Millimeters:x.xx0.5 PE CN2 CN1 1 CN1: 2 1 2 3 PIN CONNECTION 4 3 Pin Function 5 Neutral 1 6 2 Not Fitted PE 3 Line 0.126 3.20 CN2: 3.748 95.20 PIN CONNECTION 4.000 101.60 Function Pin 1 V2 2 V1 3 V1 4 GND 5 GND 6 V3 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 4-0.126 3.20 Rated Load (%) 0.063 1.60 0.125 3.18 0.098 2.50 max 1.260 32.00 max 1.750 44.45 2.000 50.80