V11 EC6AW-110 SERIES 10 WATT 4:1 INPUT DC-DC CONVERTERS FEATURES * 8.25-10W Isolated Output * Efficiency to 88.5% * Low No Load Power Consumption * 4:1 Input Range * Regulated Outputs * Input Under-Voltage Protection * Remote On/Off * Continuous Short Circuit Protection * Over Current Protection * All Ceramic Capacitor Design nd * UL60950-1 2 (Basic Insulation) Approval * Meets EN50155 with External Circuits * Shock & Vibration Meets EN50155 (EN61373) * Fire & Smoke Meets EN45545-2 * 3050m Operating Altitude OUTPUT CURRENT INPUT CURRENT MODEL INPUT OUTPUT CAPACITOR % EFF. LOAD MAX. NUMBER VOLTAGE VOLTAGE NO LOAD MIN. MAX. FULL LOAD EC6AW-110S33 43-160 VDC 3.3 VDC 0 mA 2500 mA 6 mA 85 89 mA 2500F EC6AW-110S05 43-160 VDC 5 VDC 0 mA 2000 mA 6 mA 87 105 mA 2000F EC6AW-110S12 43-160 VDC 12 VDC 0 mA 835 mA 6 mA 88 104 mA 835F EC6AW-110S15 43-160 VDC 15 VDC 0 mA 666 mA 6 mA 103 mA 88.5 666F EC6AW-110D05 43-160 VDC 5 VDC 0 mA 1000mA 6 mA 107 mA 85 1000F EC6AW-110D12 43-160 VDC 12 VDC 0 mA 416mA 6 mA 87 105 mA 416F EC6AW-110D15 43-160 VDC 15 VDC 0 mA 333mA 6 mA 87.5 104 mA 333F NOTE: 1. Nominal Input Voltage 110 VDC 1 V11 SPECIFICATIONS All Specifications Typical At Nominal Line, Full Load, and 25 Unless Otherwise Noted INPUT SPECIFICATIONS: GENERAL SPECIFICATIONS: Input Voltage Range.................... 110V ................... 43-160V Efficiency .......................................................... See Table Input Surge Voltage (100ms max.) .... 200Vdc max. I so l a ti o n V o l t a g e ........................................ 3000VDC min. 9 Under Voltage Lockout ........... Power up ...... 40V Isolation Resistance .......................... 10 Ohms min Power down ........ 38V Isolation Capacitance .. 1000pF typ. Positive Logic Remote On/Off (note 3&4) Switching Frequency ............................................................. 240KHz typ Input Filter .... PI Type Operating Ambient Temperature Range ............ -40 to +85 De-rating, Above 60 Vo=5V .. Linearly to Zero Power at +100 OUTPUT SPECIFICATIONS: Voltage Accuracy .................................................. 1.0% max. De-rating, Above 67 (note 7) .. Others . Linearly to Zero Power at +100 Voltage Balance (Dual Output) .... 2.0% max. Case Temperature (note5) .... 100 max. Transient Response: 75% - 100% Step Load Change Cooling Natural Convection Storage Temperature Range ........................ -55 to +125 Error Band .. 5% Vout nominal, Recovery Time .. < 250us Ripple & Noise, 20MHz BW (Measured with 1uF MLCC) Humidity ................................................. 95% RH max. Non-Condensing Vo=3.3V, 5V, 5V ........ 75mV pk-pk max. MTBF . MIL-HDBK-217F, GB, 25 , Full Load .. 1200Khrs typ. nd Vo=12V, 15V, 12V, 15V .. 100mV pk-pk max. Safety . Meets UL60950-1 2 (Basic insulation) EMC (note6) Meets EN50155(EN50121-3-2) with external filter Temperature Coefficient .......................................... 0.02%/C max. Short Circuit Protection .................................. Continuous Shock/Vibration . Meets EN50155(EN61373) Line Regulation (note1) ............................................. 0.2% max. Fire & Smoke ... Meet EN45545-2 Load Regulation (note2) ............ Single ........................ 0.5% max. Dimensions ... 1.250.80x0.50 inches(31.8x20.312.7mm) Dual ...... 1.0% max. Case Material ... Non-Conductive Black Plastic Weight .. 16g Cross Regulation (Dual output) Load cross variation 25%/100% ... 5.0% max. Over Voltage Protection .. Zener or TVS Clamp NOTE: Current Limit ............................. 110%-170% Nominal Output 1. Measured from high line to low line. Start up time .......................... 10ms typ. 2. Measured from full load to min. load. 3. Logic Compatibility CMOS or open collector TTL referenced to Vin. Module on .. >3.5VDC to 160VDC or open circuit Module off .. 0 to <1.2VDC 4. Suffix to the model number with negative logic remote on/off Module on ... 0 to < 1.2Vdc Module off .... >3.5VDC to 160VDC or open circuit 5. Maximum case temperature under any operating condition should not be exceeded 100. 6. For information about EN50155 and RIA12, refer to application note. 7. Others model refer to application note. CASE A Dimensions: Typical Derating curve for Natural Convection NOTE:Pin Size is 0.020.002 Inch (0.50.05 mm)DIA 120% All Dimensions In Inches (mm) -40 60 100% Tolerances Inches: X.XX= 0.02 , X.XXX= 0.010 Millimeters: X.X= 0.5 , X.XX=0.25 80% PIN CONNECTION 60% -2.50%/ Pin Single Output Dual Output 40% SEE NOTE 1 Remote On/Off Remote On/Off EC6AW-110D05 20% 2,3 -V Input -V Input 1 0% 2 4,5 NP NP 23 3 22 -40 -20 0 20 40 60 80 100 9 NP Common o Ambient Temperature( C) BOTTOM 10 NP NP VIEW 11 -V Output NC 16 9 12 NP NP 14 11 13 NP NP 0.600 14 +V Output +V Output 0.15 15.24 3.8 0.80 15 NP NP 20.3 0.50 12.7 16 -V Output Common NP 20,21,24 NP +V Input 22,23 +V Input * NC-NO CONNECTION WITH PIN * NP-NO PIN 2 1.25 31.8 0.200 5.08 0.10 2.5 LOAD(%)