LCB110 Single-Pole, Normally Closed OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description The LCB110 is a single-pole, normally closed Blocking Voltage 350 V P (1-Form-B) relay that uses optically coupled MOSFET Load Current 120 mA / mA rms DC technology to provide 3750V of input to output On-Resistance (max) 35 rms isolation. Its optically coupled outputs, which use the patented Features OptoMOS architecture, are controlled by a highly 3750V Input/Output Isolation rms efficient GaAIAs infrared LED. Low Drive Power Requirements (TTL/CMOS Compatible) The LCB110 has low on-resistance and is well suited Arc-Free With No Snubbing Circuits for most applications requiring a normally closed relay. FCC Compatible VDE Compatible Approvals No EMI/RFI Generation Small 6-Pin Package UL Recognized Component: File E76270 Machine Insertable, Wave Solderable CSA Certified Component: Certificate 1175739 Surface Mount Tape & Reel Version Available EN/IEC 60950-1 Certified Component: TUV Certificate B 09 07 49410 006 Applications Ordering Information Telecommunications Part Description Telecom Switching LCB110 6-Pin DIP (50/Tube) Tip/Ring Circuits LCB110S 6-Pin Surface Mount (50/Tube) Modem Switching (Laptop, Notebook, LCB110STR 6-Pin Surface Mount (1000/Reel) Pocket Size) * For other packaging options consult factory. Hook Switch Dial Pulsing Pin Configuration Ground Start AC/DC Configuration Ringing Injection Instrumentation 1 6 + Control Load Multiplexers 2 5 Data Acquisition Control Do Not Use 3 4 Electronic Switching N/C Load I/O Subsystems Meters (Watt-Hour, Water, Gas) DC Only Configuration Medical Equipment-Patient/Equipment Isolation 1 6 Security + Control + Load Aerospace 2 5 Control Load Industrial Controls 3 4 N/C Switching Characteristics of Normally Closed Devices Form-B I F I LOAD 90% 10% t t off on Pb e3 DS-LCB110-R09 1 www.ixysic.comLCB110 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 350 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 3.33 mW / C 1 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current Continuous AC/DC Con guration 120 mA / mA rms DC -I -- L DC Con guration 200 mA DC Peak Load Current t=10ms I - - 350 mA L P On-Resistance AC/DC Con guration I =120mA -23 35 L R ON DC Con guration I =200mA - 7 10 L Off-State Leakage Current I =5mA, V =350V I -- 1 A F L P LEAK Switching Speeds Turn-On t - 0.38 3 on I =5mA, V =10V ms F L Turn-Off t - 0.93 3 off Output Capacitance I =5mA, V =50V, f=1MHz C -25 - pF F L OUT Input Characteristics Input Control Current to Activate I =120mA I -- 5 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O R09 2 www.ixysic.com