AC-DC Power Supplies Enclosed Type Power Safety EMI OCP OVP Pulse Load Parallel World wide Inrush Remote Factor Approvals Operation current ON/OFF Correction limiting ADA-series Feature Optional parts High power & peak power Harness Power up with fan (optional) Fan unit Parallel operation / master-slave operation / N+1 redundant Attachment (optional) CE marking Harmonic attenuator (Complies with IEC61000-3-2) Universal input voltage (AC85 - 264V) Low Voltage Directive Optional : remote ON/OFF, alarms RoHS Directive Current monitor DIN rail (35mm) optional EMS Compliance : EN61204-3, EN61000-6-2 EN55022-B Safety agency approvals EN61000-3-2 UL60950-1, C-UL(CSA60950-1), EN60950-1, EN62368-1, EN50178 EN61000-4-2 Complies with DEN-AN EN61000-4-3 EN61000-4-4 EMI EN61000-4-5 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B EN61000-4-6 EN61000-4-8 5-year warranty (refer to Instruction Manual) EN61000-4-11 June 25, 2020 ADA-1Ordering information AC-DC Power Supplies Enclosed Type ADA 600 F -24 -O ADA600F 1 2 3 4 5 1 Ser ies name Example recommended EMI/EMC filter R 2 Output wattage NAC-20-472 3 Universal input 4 Output voltage 5 Optional *7 G : Lo w leakage current E : Low leakage current and EMI class A F : with F an unit High voltage pulse noise type : NAP series T : V ertical terminal block Low leakage current type : NAM series J : Connector type * A higher current rating EMI/EMC filter C : with Coating may be recommended in view of the R : Remote ON/OFF other devices that could be connected in parallel with the power supply. N1:DIN rail W : Alarms and Redundant operation Specification is changed at option,refer to Instruction Manual. Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL ADA600F-24 ADA600F-30 ADA600F-36 ADA600F-48 VOLTAGE V AC85 -264 1 or DC 120- 350 (AC64 or DC90 optionallyavailable 6) f * ( ) FREQUENCY Hz 50/60 47-63 or DC ( ) ( ) ( ) ( ) ACIN 100V 84typ Io=100% 86typ Io=100% 86typ Io=100% 86typ Io=100% EFFICIENCY % ( ) ( ) ( ) ( ) ACIN 200V 86typ Io=100% 87typ Io=100% 87typ Io=100% 89typ Io=100% ( ) INPUT ACIN 100V 0.99typ Io=100% POWER FACTOR ( ) ACIN 200V 0.98typ Io=100% 1 ( )( ) ACIN 100V* 20typ Io=100% More than 3sec.to re-start INRUSH CURRENT A *1 ( )( ) ACIN 200V 40typ Io=100% More than 3sec.to re-start ( , )( ) LEAKAGE CURRENT mA 0.75max 60Hz Accordingto IEC62368-1 and DEN-AN Io=100% VOLTAGE V 24 30 36 48 ACIN 100V*2 14 (Peak 25) convection 11 (Peak 20) convection 9 (Peak 16.5) convection 6.5 (Peak 12.5) convection ACIN 100V*2 21 (Peak 25) forced air 16.5 (Peak 20) forced air 14 (Peak 16.5) forced air 10.5 (Peak 12.5) forced air CURRENT A ACIN 200V*2 15 (Peak 31) convection 12 (Peak 24.5) convection 10 (Peak 20.5) convection 7 (Peak 15.5) convection 2 ACIN 200V* 25 (Peak 31) forced air 20 (Peak 24.5) forced air 16.5 (Peak 20.5) forced air 12.5 (Peak 15.5) forced air LINE REGULATION mV 96max 120max 144max 192max LOAD REGULATION mV 150max 180max 240max 300max 3 0to +50 * 120max 160max 200max 200max C RIPPLE mVp-p 3 OUTPUT -10- 0 * 160max 230max 260max 300max C 3 0to +50 * 150max 190max 230max 250max C RIPPLE NOISE mVp-p 3 -10- 0 * 180max 250max 280max 400max C TEMPERATURE REGULATION mV 0to +50 240max 300max 360max 480max C *4 DRIFT mV 96max 120max 144max 192max ( , ) START-UP TIME ms 500max ACIN 100V Io=100% HOLD-UP TIME ms 20typ (ACIN 100V, Io=100%) OUTPUTVOLTAGE ADJUSTMENT RANGE V 21.6- 27.0 27.0- 33.0 33.0- 41.0 41.0- 52.8 OUTPUTVOLTAGE SETTING V 23.5- 24.5 29.0- 31.0 35.0- 37.0 47.0- 49.0 OVERCURRENT PROTECTION Worksover 101%of peak current and recovers automatically OVERVOLTAGE PROTECTION V 31 - 34.5 40-4851-6064-76 PROTECTION ( ) CIRCUIT AND OPERATING INDICATION LED Green OTHERS ( ), ( ) ( , ) ALARM OUTPUT Detectinglow input voltage PF detectinglow output voltage LV . Optional:-W refer to Instruction Manual 6 ( ) ( , ) REMOTE ON/OFF RC Requirementfor external source Option:-R refer to Instruction Manual6 5 , , , ( ) INPUT-OUTPUT RC * AC3 000V 1minute Cutoff current= 10mA DC500V 50M min At Room Temperature - W , , , ( ) ISOLATION INPUT-FG AC2 000V 1minute Cutoff current= 10mA DC500V 50M min At Room Temperature W *5 , , ( ) OUTPUT-RC-FG AC500V1minute Cutoff current= 100mA DC500V 50MW min At RoomTemperature , , ( )( ), , ( , ) OPERATINGTEMP.HUMID.ANDALTITUDE -10 to +71C 20- 90%RH Non condensing Refer to Derating 3 000m 10 000feet max , , ( ), , ( , ) STORAGE TEMP.HUMID.AND ALTITUDE -20 to +75C 20- 90%RH Non condensing 9 000m 30 000feet max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y andZ axis 2 IMPACT 196.1m/s (20G), 11ms, once eachX, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL(CSA60950-1), EN60950-1, EN62368-1, EN60065, EN50178 Complies with DEN-AN SAFETY AND NOISE CONDUCTED NOISE Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B REGULATIONS *8 HARMONICATTENUATOR Complies with IEC61000-3-2 ( )( ) CASE SIZE/WEIGHT 65 127 195mm 2.56 5 7.68 inches W H D without terminal block /1.5kg max X X X X X X OTHERS COOLING METHOD Convection/Forced air *1 The value is primary surge.The current of input surge to a built-in EMI/EMC Filter (0.2ms or *4 Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, less) is excluded. with the input voltage held constant at the rated input/output. *2 Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown *5 Applicab le when remote control (optional) is added. in Derating. *6 Derating is required.Consult us for details. *3 This is the value that measured on measuring board with capacitor of 22mF within 150mm *7 Please contact us about saf ety approvals for the model with option. from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to *8 Please contact us about class C . KEISOKU-GIKEN: RM101). * A sound ma y occur from power supply at pulse loading. June 25, 2020 ADA-2