AC-DC Power Supplies Medical Type Medical Power Safety EMI OCP OVP Parallel 1U Pulse Load World wide Inrush Remote electric Factor Approvals Operation current ON/OFF equipment Correction limiting AEA-series Feature 5-year warranty (Refer to Instruction Manual) High power & peak power CE marking High efficiency Low profile (41mm, 1.61 inch = meet to 1U height) Low Voltage Directive For medical electric equipment (ANSI/AAMI ES60601, RoHS Directive EN60601-1 3rd, IEC60601-1-2 4th Ed.) Suitable for BF application (Output-FG : 1MOPP, Input-Output : EMI 2MOPP) Complies with FCC-B, CISPR11-B, CISPR32-B, EN55011-B, OVC III (according to EN62477-1) EN55032-B, VCCI-B Complies with SEMI F47 (Refer to Instruction Manual) UL508 (Optional) EMS Compliance : EN61204-3, EN61000-6-2 IEC60601-1-2(2014), EN60601-1-2(2015) Safety agency approval EN61000-4-2 UL62368-1, ANSI/AAMI ES60601-1 EN61000-4-3 C-UL (CAN/CSA62368-1, CAN/CSA60601-1) EN61000-4-4 EN62368-1, EN60601-1 3rd EN61000-4-5 Complies with IEC60601-1-2 4th Ed. EN61000-4-6 EN62477-1 (OVC III) EN61000-4-8 UL508 (Optional) EN61000-4-11 October 29, 2021 AEA-1Ordering information AC-DC Power Supplies Medical Type AE A 600 F -OO -O AEA600F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R 2 Single output EAC-20-472 3 Output wattage 4 Universal input 5 Output voltage *1 6 Optional C : with Coating N : with cover T : V ertical terminal block J : Connector type High voltage pulse noise type : EAP series R3 : with Subfeatures Low leakage current type : EAM series (5V1A AUX,12V1A AUX *Use of an EMI/EMC filter is recommended Remote ON/OFF, Alarm) when a power supply is connected with several devices so that additional filtering is necessary. T5 : UL508 2MOPP * Make sure that your final application will meet P5 : shutdo wn type the required EMC standard by measuring the overcurrent protection EMI level of the power supply used together For option details, refer to instruction with an EMI/EMC filter. manual 6.1. Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL AEA600F-24 AEA600F-36 AEA600F-48 MAX OUTPUT WATTAGE W 600 601.2 600 ACIN 100V 24V 20.0 (Peak 42.0) A 36V 13.4 (Peak 28.0) A 48V 10.0 (Peak 21.0) A DC OUTPUT (forced air) ACIN 230V 24V 25.0 (Peak 52.5) A 36V 16.7 (Peak 35.0) A 48V 12.5 (Peak 26.3) A SPECIFICATIONS MODEL AEA600F-24 AEA600F-36 AEA600F-48 VOLTAGE V AC85 - 264 1f (Output derating is required at AC85V - 170V. See Derating) ACIN 100V 5.7typ (Io=20A) 5.7typ (Io=13.4A) 5.7typ (Io=10A) CURRENT A ACIN 230V 2.9typ (Io=25A) 2.9typ (Io=16.7A) 2.9typ (Io=12.5A) FREQUENCY Hz 50/60 (45 - 66) ACIN 100V 92.0%typ (Io=20A) 92.0%typ (Io=13.4A) 92.0%typ (Io=10A) EFFICIENCY % INPUT ACIN 230V 94.5%typ (Io=25A) 95.0%typ (Io=16.7A) 95.0%typ (Io=12.5A) ACIN 100V 0.98typ (Io=20A) 0.98typ (Io=13.4A) 0.98typ (Io=10A) POWER FACTOR ACIN 230V 0.95typ (Io=25A) 0.95typ (Io=16.7A) 0.95typ (Io=12.5A) ACIN 100V 20/40typ (Io=20A) 20/40typ (Io=13.4A) 20/40typ (Io=10A) *2 INRUSH CURRENT A ACIN 230V 40/40typ (Io=25A) 40/40typ (Io=16.7A) 40/40typ (Io=12.5A) LEAKAGE CURRENT mA 0.3max (ACIN 240V 60Hz, Io=100%, According to IEC60601-1) VOLTAGE V 24 36 48 14.0 (Peak 42.0) convection 9.4 (Peak 28.0) convection 7.0 (Peak 21.0) convection ACIN 100V 20.0 (Peak 42.0) forced air 13.4 (Peak 28.0) forced air 10.0 (Peak 21.0) forced air CURRENT A 17.5 (Peak 52.5) convection 11.7 (Peak 35.0) convection 8.8 (Peak 26.3) convection ACIN 230V 25.0 (Peak 52.5) forced air 16.7 (Peak 35.0) forced air 12.5 (Peak 26.3) forced air LINE REGULATION mV 96max 144max 192max LOAD REGULATION mV 150max 240max 300max 0 to +50C 120max 200max 200max *3 RIPPLE mVp-p OUTPUT -20 to 0C 200max 300max 350max 0 to +50C 150max 230max 250max *3 RIPPLE NOISE mVp-p -20 to 0C 230max 350max 500max TEMPERATURE REGULATION mV 0 to +50C 240max 360max 480max *4 DRIFT mV 96max 144max 192max START-UP ms 750typ HOLD-UP ms 20typ (ACIN 230V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 21.6 to 26.4 32.4 to 39.6 43.2 to 52.8 OUTPUT VOLTAGE SETTING V 23.5 to 24.5 35.0 to 37.0 47.0 to 49.0 *5 OVERCURRENT PROTECTION Works over 101% of peak current and recovers automatically OVERVOLTAGE PROTECTION V 30 to 33.6 45 to 50.4 60 to 69.6 PROTECTION ALARM Optional (Input voltage alarm : PR, Output voltage alarm : PG) CIRCUIT AND REMOTE ON/OFF Optional OTHERS AUX1 Optional (12V1A) AUX2 Optional (5V1A) *6 INPUT-OUTPUT-PR-PG-RC-AUX AC4,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) 2MOPP INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) 1MOPP ISOLATION *6 OUTPUT-PR-PG-RC-AUX-FG AC1,500V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) 1MOPP *6 OUTPUT-AUX1-PR-PG-RC-AUX2 AC100V 1minute, Cutoff current = 25mA, DC100V 10M min (At Room Temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +70C, 20 - 90%RH (Non condensing), 5,000m (16,500feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis UL62368-1,ANSI/AAMI ES 60601-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1,CAN/CSA-C22.2 No.60601-1) SAFETY AND AGENCY APPROVALS EN62368-1,EN60601-1 3rd EN62477-1 (OVCIII) UL508 (Optional), Complies with IEC60601-1-2 4th Ed. NOISE CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR32-B, EN55011-B, EN55032-B REGULATIONS *7 Complies with IEC61000-3-2 (Class A) HARMONIC ATTENUATOR CASE SIZE/WEIGHT 41127186mm 1.6157.32 inches (WHD) (without terminal block) / 1.0kg max OTHERS COOLING METHOD Convection/Forced air *1 The listed options ma y affect the published standard specifications. *5 The output is shut do wn when the overcurrent protection continues. Please contact us for detailed product specification *6 Applicab le when AUX and remote control (optional) is added. *2 The current of input surge to a b uilt-in EMI/EMS Filter (0.2ms or less) is excluded. *7 Please contact us about another class . *3 Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKUGIKEN:RM104). *Sound noise ma y be generated by power supply in case of pulse load. Please refer to the instruction manual 1.8. *4 Dr ift is the change in DC output for an eight hours period after a half-hour warm-up at 25C. October 29, 2021 AEA-2