. AC-DC Power Supplies Bus Converter Power Module Type Power Low Profile Safety OVP Parallel World wide Inrush Factor Approvals Operation current Correction limiting DPF-series Power factor correction module CE marking Low Voltage Directive RoHS Directive Feature Harmonic attenuator (Complies with IEC61000-3-2) Safety agency approvals High efficiency 90% (AC100V), 95% (AC200V) Universal input voltage (AC85 - 264V) UL, C-UL recognized, TuV approved Built-in inrush current protection Parallel operation is possible (Built-in current balancing function) Built-in overvoltage and thermal protection circuits Inverter operation monitoring (IOG) Enable signal (ENA) Auxiliary power supply for external signal (AUX) Ideal for distributed power systems 5-year warranty February 5, 2021 DPF-1Ordering information AC-DC Power Supplies Bus Converter Power Module Type DPF 1000 DPF1000 1 2 1 Ser ies name R 2 Output wattage MODEL DPF1000 AC INPUT V AC85 - 264 AC170- 264 , , MAX OUTPUTWATTAGE W 1 000 1 500 DC OUTPUTVOLTAGE V DC360 SPECIFICATIONS MODEL DPF1000 VOLTAGE V AC85 - 264 1 AC170 -264 1 f f POWER FACTOR CORRECTION RANGE V AC85 - 255 1 f ( ) ( ) CURRENT A 11.5typ ACIN 100V 8.5typ ACIN 200V FREQUENCY Hz 50/60 (47-63) INPUT INRUSH CURRENT A Limitedbyexternal resistance ( ) ( ) EFFICIENCY % 90typ ACIN 100V 95typ ACIN 200V POWER FACTOR 0.98typ (ACIN 100V) 0.95typ (ACIN 200V) ( , ) LEAKAGE CURRENT mA 0.75max 60Hz Accordingto IEC60950 and DEN-AN 1 , , WATTAGE W * 1 000 1 500 2 OUTPUT VOLTAGE V * DC360 *3 VOLTAGE ACCURACY V 20 t OVERVOLTAGE PROTECTION V DC400- 450 The powerfactor corrector function stops IOG Inverter operation monitoring, Open-collector output, Maximum sink current 10mA, Maximum allowancevoltage 35V PROTECTION , , , CIRCUIT AND ENA Enable signal Open-collector output Maximum sink current 10mA Maximum allowance voltage 35V OTHERS , , AUX Auxiliarypower supplyfor external signal Outputvoltage:6.5 - 8.5V maximum Output current:10mA ( ), , OTHERS Parallel operation possible Current balancing function N+1 redundant operation possible Thermal protection INPUT-OUTPUT Non isolated ISOLATION , , , , ( ) INPUT OUTPUT-FG AC3 000V 1minute Cutoff current= 10mA DC500V 50M min 20 15 W t C 4 , * ( ), ( )( ), , ( , ) OPERATINGTEMP. HUMID.ANDALTITUDE -20 to +85C Aluminum baseplate 20 - 95%RH Noncondensing Refer to Derating 3 000m 10 000feet max , , ( ), , ( , ) STORAGE TEMP. HUMID.ANDALTITUDE -40 to +85 20- 95%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT 2 , ( ), , , VIBRATION 10- 55Hz 49.0m/s 5G 3minutes period 60minutes each alongX Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once eachX Y and Z axis , , AGENCY APPROVALS UL60950-1 C-UL EN60950-1 Complies with DEN-AN and IEC60950-1 SAFETY *5 HARMONICATTENUATOR Complies with IEC61000-3-2 ( ) CASE SIZE/WEIGHT 118.6X12.7X85mm 4.67X0.5X3.35 inches WXHXD /200g max OTHERS ( ) COOLINGMETHOD Conduction cooling e.g. heatradiation from the aluminum base plate to the attached heat sink *1 Refer to Derating. *4 Please consult us in regard to use from -40 C. *2 When the input voltage is more than 255V, the power factor corrector function stops, and the *5 Please contact us about class C . output voltage becomes rectified AC input voltage. * Exter nal components are required. Refer to standard connection method. *3 The value included the output setting and the line regulation, the load regulation and the temperature regulation. However, the input voltage is in the power factor correction range. February 5, 2021 DPF-2