. AC-DC Power Supplies Bus Converter Power Module Type Power Low Profile Safety OVP World wide Inrush Factor Approvals current Correction limiting DPG-series Power factor correction module CE marking Low Voltage Directive RoHS Directive Feature Harmonic attenuator (Complies with IEC61000-3-2) Safety agency approvals High efficiency 93% (AC100V), 96% (AC200V) Universal input voltage (AC85 - 264V) UL, C-UL recognized, TuV approved Built-in inrush current protection Built-in overvoltage and thermal protection circuits Enable signal (ENA) Auxiliary power supply for external signal (AUX) Ideal for distributed power systems 5-year warranty February 5, 2021 DPG-1. Ordering information AC-DC Power Supplies Bus Converter Power Module Type DPG 750 -O DPG 1 2 3 1 Series name R 2 Output power 500 : 500W (ACIN 200V) 750 : 750W (ACIN 200V) 3 Optional T : with Mounting hole (f3.4 thru) MODEL DPG500 DPG750 AC INPUT V AC85 - 264 AC170 - 264 AC85 - 264 AC170 - 264 *1 MAX OUTPUT WATTAGE W 300 500 500 750 DC OUTPUT VOLTAGE V *2 360 SPECIFICATIONS MODEL DPG500 DPG750 VOLTAGE V AC85 - 264 1f AC170 - 264 1f AC85 - 264 1f AC170 - 264 1f POWER FACTOR CORRECTION RANGE V AC85 - 264 1f CURRENT A 3.47typ (ACIN 100V) 2.86typ (ACIN 200V) 5.72typ (ACIN 100V) 4.24typ (ACIN 200V) FREQUENCY Hz 50/60 (47 - 63) Hz INPUT INRUSH CURRENT A Limited by external resistance EFFICIENCY % 92typ (ACIN 100V) 95typ (ACIN 200V) 93typ (ACIN 100V) 96typ (ACIN 200V) POWER FACTOR 0.96typ (ACIN 100V) 0.93typ (ACIN 200V) 0.96typ (ACIN 100V) 0.93typ (ACIN 200V) LEAKAGE CURRENT mA 0.75 max (60Hz, According to IEC60950 and DEN-AN) *1 WATTAGE W 300 500 500 750 *2 OUTPUT VOLTAGE V 360 VOLTAGE ACCURACY *3 2% OVERVOLTAGE PROTECTION V DC400 - 450V The power factor corrector function stops PROTECTION *4 CIRCUIT AND ENA Enable signal, Open-drain output, Maximum sink current 10mA, Maximum allowance voltage 35V OTHERS OTHERS *5 Parallel operation impossible , Thermal protection INPUT-OUTPUT Non isolated ISOLATION INPUT, OUTPUT-FG AC2,800V 1minute Cutoff current = 10mA, DC500V, 50MW min (2015C) OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to Derating) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 49.0m/s (5G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL, EN60950-1 Complies with DEN-AN and IEC60950-1 SAFETY *6 HARMONIC ATTENUATOR Complies with IEC61000-3-2 CASE SIZE/WEIGHT 58.4X12.7X61mm 2.3X0.5X2.4 inches (WXHXD) / 100g max OTHERS COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1 Refer to Derating. *2 When the input voltage is more than 240V, the output voltage becomes the value proportional to the input voltage. *3 The value included the output setting and the line regulation, the load regulation and the temperature regulation. However, the input voltage is less than 240V. *4 Refer to the instruction Manual. *5 The thermal protection stops the power factor corrector function and the ENA signal. *6 Please contact us about class C. February 5, 2021 DPG-2