AC-DC Power Supplies Enclosed Type EMI Inrush OVP Remote 1U Power Safety OCP Parallel current ON/OFF Factor Approvals Operation limiting Correction FETA-series Feature 3-year warranty (Refer to Instruction Manual) High power density Low profile (Meets 1U height.) CE marking High output voltage (FETA7000T-144, FETA7000ST-144) Low voltage Directive High efficiency RoHS Directive Harmonic attenuator (FET A2500BA, 3000BA, 7000ST : Complies with IEC61000-3-2 EMS Compliance : EN61204-3, EN61000-6-2 Class A FETA7000T : Complies with IEC61000-3-12) EN61000-4-2 Complies with SEMI F47 EN61000-4-3 Parallel Operation / Parallel Redundancy Operation EN61000-4-4 Alarm signals, Remote ON / OFF and other functions EN61000-4-5 EN61000-4-6 Safety agency approvals EN61000-4-8 EN61000-4-11 UL62368-1, C-UL(CSA62368-1), EN62368-1 EMI Complies with FCC Part 15-A, CISPR32-A, EN55032-A, VCCI-A (F ETA7000ST : Complies with FCC Part 15-A, CISPR32-A, EN55032-A, VCCI-A by connecting an external EMI/EMC filter) June 25, 2020 FETA-1Ordering information AC-DC Power Supplies Enclosed Type FET A 2500 B A -OO -O FETA2500BA 1 2 3 4 5 6 7 1 Series name Example recommended EMI/EMC filter R 2 Single output NAC-20-472 3 Output wattage 4 200/230V input 5 Version 6 Output voltage 7 Optional F2: Reverse air exhaust R: with Remote ON/OFF High voltage pulse noise type : NAP series Positive logic control Low leakage current type : NAM series *A higher current r ating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL FETA2500BA-36 FETA2500BA-48 *1 MAX OUTPUT WATTAGE W 1980 2496 DC OUTPUT 36V 55A 48V 52A SPECIFICATIONS MODEL FETA2500BA-36 FETA2500BA-48 VOLTAGE V AC170 - 264 1f (Output derating is required at AC170V - 180V. Refer to Derating) CURRENT A ACIN 200V 11.3typ 13.8typ FREQUENCY Hz 50 / 60 (47 - 63) 80typ (Io=10%) 83typ (Io=10%) 87typ (Io=20%) 89typ (Io=20%) INPUT EFFICIENCY % ACIN 230V 91typ (Io=50%) 92.5typ (Io=50%) 90typ (Io=100%) 91.5typ (Io=100%) ACIN 230V POWER FACTOR 0.98typ (Io=100%) INRUSH CURRENT A ACIN 200V *2 20max / 60max (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start) LEAKAGE CURRENT mA 0.85max (ACIN 240V 60Hz, Io=100%, According to IEC62368-1) VOLTAGE V 36 48 ACIN 170V-180V Output derating is required at ACIN 180V or less (refer to Derating) CURRENT A ACIN 180V-264V 55 52 LINE REGULATION mV 144max 192max LOAD REGULATION mV 360max 480max *3 0 to +50C 300max 360max RIPPLE mVp-p *3 -10 to 0C 360max 480max *3 0 to +50C 360max 480max RIPPLE NOISE mVp-p OUTPUT -10 to 0C *3 480max 600max 0 to +50C 360max 480max TEMPERATURE REGULATION mV -10 to +50C 440max 600max *4 DRIFT mV 144max 192max START-UP TIME s 1.7max (ACIN 200V, Io=100%) 10typ (Io=100%) HOLD-UP TIME ms ACIN 200V 20typ (Io=50%) *5 *6 OUTPUT VOLTAGE ADJUSTMENT RANGE V 28.80 - 39.60 38.40 - 52.80 OUTPUT VOLTAGE SETTING V 36.00 - 37.44 48.00 - 49.92 Activate over 105% - 120% of rated current and recovers automatically. OVERCURRENT PROTECTION *7 (Output voltage shuts down when the output voltage continuously drops due to overcurrent protection.) PROTECTION *7 OVERVOLTAGE PROTECTION V 42.00 - 45.00 56.00 - 60.00 CIRCUIT AND DC OK LAMP LED (Green) OTHERS ALARM LAMP LED (Amber) REMOTE ON/OFF Provided INPUT-OUTPUT-AUX-RC-WRN-PG AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) ISOLATION OUTPUT-AUX-RC-WRN-PG-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-AUX-RC-WRN-PG AC100V 1minute, Cutoff current = 100mA, DC100V 50MW min (At room temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C (Refer to Derating), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +85C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each along X, Y and Z axis AGENCY APPROVALS UL62368-1, C-UL (CSA62368-1), EN62368-1 SAFETY AND CONDUCTED NOISE Complies with FCC Part 15-A, CISPR32-A, EN55032-A, VCCI-A NOISE REGULATIONS *8 HARMONIC ATTENUATOR Complies with IEC61000-3-2 Class A *9 CASE SIZE/WEIGHT 102X41X340mm 4.02X1.61X13.39 inches (WXHXD) / 2.3kg max OTHERS COOLING METHOD Forced cooling (internal fan) *1 AUX output power is not included. *7 Output voltage recovers from protection by shutting down the input voltage and waiting *2 The current of input surge to a built-in noise filter (0.2ms or less) is excluded. more than 10 seconds then turning on AC input again, or turning off the output voltage by *3 Measured by 500MHz oscilloscope. remote control. Ripple and r ipple noise is measured on measuring board with capacitor of 22mF within *8 Please contact us about another class . 150mm from the output terminal. *9 Case siz e contains neither the terminal blocks, connector and screw. *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, * To meet the specifications, do not operate over-loaded condition. with the input voltage held constant at the rated input/output. * A sound may occur from power supply at peak loading. *5 Can t be used abo ve the rated output current and the rated output power. *6 When the output v oltage is adjusted to higher than 49.92V and the load factor is over 70% of the rated current, if the load current changes quickly (< 200msec), the output voltage drops approximately 5V below the setting voltage. June 25, 2020 FETA-2