AC-DC Power Supplies Medical Type Medical Power Safety EMI OCP OVP World wide Inrush Remote electric Factor Approvals current ON/OFF equipment Correction limiting GMA-series Feature CE marking Wattage 300Wmax Low Voltage Directive For medical electric equipment (ANSI/AAMI ES60601-1, RoHS Directive EN60601-1 3rd, IEC60601-1-2 4th Ed.) Suitable for BF application ( Output-FG : 1MOPP, EMI Input-Output : 2MOPP) Complies with FCC-B, CISPR11-B, CISPR32-B, EN55011-B, 2 4 standard footprint EN55032-B, VCCI-B With Remote ON/OFF (Optional) With AUX1 (12V 1A), AUX2 (5V 1A) (Optional) EMS Compliance : EN61204-3, EN61000-6-2 IEC60601-1-2(2014), EN60601-1-2(2015) Safety agency approvals EN61000-4-2 UL62368-1, ANSI/AAMI ES60601-1 EN61000-4-3 C-UL (CSA62368-1, CAN/CSA60601-1) EN61000-4-4 EN62368-1, EN60601-1 3rd EN61000-4-5 Complies with IEC60601-1-2 4th Ed. EN61000-4-6 EN61000-4-8 5-year warranty (Refer to Instruction Manual) EN61000-4-11 June 29, 2020 GMA-1Ordering information AC-DC Power Supplies Medical Type GM A 300 F -OO -O GMA300F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R 2 Single output EAC-06-472 3 Output wattage 4 Universal input 5 Output voltage *6 6 Optional C : with Coating J1 : Input connector VH (J.S.T.) connector type High voltage pulse noise type : EAP series J3 : Horizontal input connector Low leakage current type : EAM series VH (J.S.T.) connector type *A higher current r ating EMI/EMC filter R3 : with Subfeatures may be recommended in view of the (5V1A AUX, 12V1A AUX, other devices that could be connected Remote ON/OFF) in parallel with the power supply. Specification changes when options are added. Please refer to the instruction manual for more detail. This power supply is manufactured using SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL GMA300F-12 GMA300F-24 GMA300F-48 GMA300F-56 MAX OUTPUT WATTAGE W 300 300 302.4 302.4 DC OUTPUT 12V 25A 24V 12.5A 48V 6.3A 56V 5.4A SPECIFICATIONS MODEL GMA300F-12 GMA300F-24 GMA300F-48 GMA300F-56 *3 VOLTAGE V AC85 - 264 1f (Output derating is required at AC85V - 115V. See Derating) ACIN 115V 3.3typ CURRENT A ACIN 230V 1.8typ FREQUENCY Hz 50 / 60 (45 - 66) ACIN 115V 90typ 91typ 91typ 91typ EFFICIENCY % INPUT ACIN 230V 92typ 93typ 93typ 93typ POWER FACTOR ACIN 115V 0.95typ (Io=100%) ACIN 230V 0.90typ ACIN 115V 30typ (Io=100%) (At cold start, Ta=25 ) INRUSH CURRENT A ACIN 230V 60typ (Io=100%) (At cold start, Ta=25 ) LEAKAGE CURRENT mA 0.13 / 0.30max (ACIN 100/240V 60Hz, Io=100%, According to IEC60601-1) VOLTAGE V 12 24 48 56 CURRENT A 25 12.5 6.3 5.4 *4 LINE REGULATION mV 48max 96max 192max 192max *4 LOAD REGULATION mV 100max 150max 240max 240max 0 to +50C 240max 240max 400max 400max *1 RIPPLE mVp-p -20 to 0C 320max 320max 500max 500max 0 to +50C 300max 300max 500max 500max *1 RIPPLE NOISE mVp-p -20 to 0C 360max 360max 580max 580max OUTPUT 0 to +50C 120max 240max 480max 480max TEMPERATURE REGULATION mV -20 to +50C 150max 290max 600max 600max *2 DRIFT mV 48max 96max 192max 192max 400typ (ACIN 115V, Io=100%) START-UP TIME ms *Start-up time is 900ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME ms 16typ (ACIN 115V, Io=85%) / 12typ (ACIN 115V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 11.40 13.20 22.80 26.40 45.60 52.80 52.00 56.00 OUTPUT VOLTAGE SETTING V 12.00 12.48 24.00 24.96 48.00 49.92 55.00 56.00 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION OVERVOLTAGE PROTECTION V 13.80 to 16.80 27.60 to 33.60 55.20 to 67.20 60.00 to 70.50 CIRCUIT AND AUX1 (12V1A) Optional OTHERS AUX2 (5V1A) Optional REMOTE ON/OFF Optional *7 INPUT-OUTPUT-RC-AUX AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPP INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOPP ISOLATION *7 OUTPUT-RC-AUX-FG AC1,500V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOPP *7 OUTPUT-RC-AUX AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) *3 *8 OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +70C, 20 - 90%RH (Non condensing), 5,000m (16,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -30 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis SAFETY AND AGENCY APPROVALS UL62368-1, ANSI/AAMI ES60601-1, C-UL, EN62368-1, EN60601-1 3rd, Complies with IEC60601-1-2 4th Ed. NOISE CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR32-B, EN55011-B, EN55032-B REGULATIONS HARMONIC ATTENUATOR *5 Complies with IEC61000-3-2 (class A) CASE SIZE/WEIGHT 50.8 37 101.6mm 2.0 1.5 4.0 inches (W H D) / 230g max OTHERS COOLING METHOD Forced air (Requires external fan) *1 This is the value that measured on measuring board with capacitor of 22 mF at 150mm from *6 Specication is changed at option, refer to Instruction Manual. output terminal. *7 Applicable when AUX and remote control (optional) is added. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *8 Please contact us about for more detail. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25 , with * To meet the specications. Do not operate over-loaded condition. the input voltage held constant at the rated input/output. * Parallel operation is not possible. *3 Refer to Derating * Sound noise may be generated by power supply in case of pulse load. *4 Please contact us about dynamic load and input response. * Substrate bottom has a Electric potential. Insulation is required. *5 Please contact us about another class. June 29, 2020 GMA-2