Ordering information AC-DC Power Supplies Open Frame/Enclosed type LC A 10 S -5 -O LCA10S 123456 1Series name R Recommended EMI/EMC Filter 2100/120V input NAC-06-472 3Output wattage 4Single output 5Output voltage 6Optional *3 C :with Coating G :Low leakage current Y :with Potentiometer High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL LCA10S-5 LCA10S-5-H LCA10S-12 LCA10S-15 LCA10S-24 MAX OUTPUT WATTAGE W 10 10 10.8 10.5 12 DC OUTPUT 5V 2A 5V 2A 12V 0.9A 15V 0.7A 24V 0.5A SPECIFICATIONS MODEL LCA10S-5 LCA10S-5-H LCA10S-12 LCA10S-15 LCA10S-24 VOLTAGE V AC85 - 132 1 or DC110 - 170 f ( ) CURRENT A ACIN 100V 0.3typ Io=100% FREQUENCY Hz 47 - 440 or DC INPUT EFFICIENCY % 71typ 71typ 75typ 75typ 78typ ( ) INRUSH CURRENT A ACIN 100V 25typ Io=100% LEAKAGE CURRENT mA 0.5max (60Hz, According to UL, CSA and DEN-AN) LCA VOLTAGE V 5512 15 24 ( ) CURRENT A 22 Peak 3 0.9 0.7 0.5 LINE REGULATION mV 20max 20max 48max 60max 96max LOAD REGULATION mV 40max 40max 100max 120max 150max 1 0to+50 * 80max 80max 120max 120max 120max C RIPPLE mVp-p 1 * -10-0C 140max 140max 160max 160max 160max *1 0to+50 120max 120max 150max 150max 150max C OUTPUT RIPPLE NOISE mVp-p 1 -10-0 * 160max 160max 180max 180max 180max C TEMPERATURE REGULATION mV 50max 50max 120max 150max 240max *2 DRIFT mV 20max 20max 48max 60max 96max ( , ) START-UP TIME ms 100max ACIN 85V Io=100% ( , ) ( , ) HOLD-UP TIME ms 10typ ACIN 85V Io=100% 20typ ACIN 100V Io=100% ( , , ) OUTPUT VOLTAGE ADJUSTMENT RANGE V Fixedwhich can be adjusted the output is available as optional:5V -5 to +10% : 12 15 24V 10% t OUTPUT VOLTAGE SETTING V 4.9 - 5.3 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 ( ) OVERCURRENT PROTECTION Works over 105% of rating works over 105% of peak current at option -H and recovers automatically , OVERVOLTAGE PROTECTION Works over 115% of rating by zener diode clamping PROTECTION CIRCUIT AND OPERATING INDICATION Not provided OTHERS REMOTE SENSING Not provided REMOTE ON/OFF Not provided , , , ( ) INPUT-OUTPUT AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature W , , , ( ) ISOLATION INPUT-FG AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature W , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature W OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60 , 20 - 90%RH (Non condensing)(Refer to DERATING CURVE), 3,000m (10,000feet) max C , , ( ), , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis SAFETY AND , AGENCY APPROVALS UL60950-1 CSA C22.2 No.60950-1 Complies with DEN-AN NOISE , REGULATIONS CONDUCTED NOISE Complies with FCC-B VCCI-B CASE SIZE/WEIGHT 49 17 94mm (W H D) / 65g max X X X X OTHERS COOLING METHOD Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. *3 Please contact us about safety approvals for the model with option. * Avoid prolonged use under over-load. LCA-2LCA10S External view LCA Performance data STATIC CHARACTERISTICS (LCA10S-5) RISE TIME & FALL TIME (LCA10S-5) OVERCURRENT CHARACTERISTICS (LCA10S-5) DERATING CURVE LCA-3