Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDA 10 F -5 -O LDA10F 12345 1Series name R Recommended EMI/EMC Filter 2Output wattage NAC-06-472 3Universal input 4Output voltage 5Optional *2 C :with Coating G :Low leakage current S :with Chassis SN:with Chassis & cover High voltage pulse noise type : NAP series Y :with Potentiometer Low leakage current type : NAM series *The EMI/EMC Filter is recommended *to connect with several devices. MODEL LDA10F-3 LDA10F-5 LDA10F-12 LDA10F-15 LDA10F-24 MAX OUTPUT WATTAGE W 6 10 10.8 10.5 12 DC OUTPUT 3V 2.0A 5V 2.0A 12V 0.9A 15V 0.7A 24V 0.5A SPECIFICATIONS MODEL LDA10F-3 LDA10F-5 LDA10F-12 LDA10F-15 LDA10F-24 VOLTAGE V AC85 - 264 1 or DC110 - 370 f ( ) ACIN 100V 0.25typ Io=100% CURRENT A ( ) ACIN 200V 0.16typ Io=100% LDA FREQUENCY Hz 47 - 440 or DC INPUT EFFICIENCY % 68typ 72typ 74typ 74typ 78typ ( )( ) ACIN 100V 15typ Io=100% At cold start INRUSH CURRENT A ( )( ) ACIN 200V 30typ Io=100% At cold start ( , , , ) LEAKAGE CURRENT mA 0.75max 60Hz According to UL CSA VDE and DEN-AN VOLTAGE V 3 5 12 15 24 CURRENT A 2 2 0.9 0.7 0.5 LINE REGULATION mV 20max 20max 48max 60max 96max LOAD REGULATION mV 40max 40max 100max 120max 150max 0to+50 80max 80max 120max 120max 120max C RIPPLE mVp-p -10-0 140max 140max 160max 160max 160max C 0to+50 120max 120max 150max 150max 150max C OUTPUT RIPPLE NOISE mVp-p -10-0 160max 160max 180max 180max 180max C TEMPERATURE REGULATION mV 50max 50max 120max 150max 240max *1 DRIFT mV 20max 20max 48max 60max 96max ( , ) START-UP TIME ms 200max ACIN 100V Io=100% ( , ) ( , ) ( , ) HOLD-UP TIME ms 10typ ACIN 85V Io=100% 20typ ACIN 100V Io=100% 100typ ACIN 200V Io=100% OUTPUT VOLTAGE ADJUSTMENT RANGE V 2.85 - 3.6 Fixed which can be adjusted the output is available as option :5, 12, 15, 24V 10%) t OUTPUT VOLTAGE SETTING V 4.9 - 5.3 11.5 - 12.5 14.4 - 15.6 23.0 - 25.0 xx OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OVERVOLTAGE PROTECTION 4.00V min Works over 115% of rating, by zener diode clamping PROTECTION CIRCUIT AND OPERATING INDICATION Not provided OTHERS REMOTE SENSING Not provided REMOTE ON/OFF Not provided , , , ( ) INPUT-OUTPUT AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature W , , , ( ) ISOLATION INPUT-FG AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature W , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature W , , ( )( ) , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60 20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max C , , ( ) , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75C 20 - 90%RH Non condensing 9 000m 30 000feet max ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis SAFETY AND AGENCY APPROVALS UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 NOISE REGULATIONS CONDUCTED NOISE Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B CASE SIZE/WEIGHT 50 21 105mm (W H D) /75g max (without chassis and cover) X X X X OTHERS COOLING METHOD Convection *1 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *2 Please contact us about safety approvals for the model with option. * Avoid prolonged use under over-load. * Series/Parallel operation with other model is not possible. * Derating is required when operated with chassis and cover. LDA-2LDA10F External view LDA Performance data ( ) ( ) STATIC CHARACTERISTICS LDA10F-5 RISE TIME & FALL TIME LDA10F-5 ( ) OVERCURRENT CHARACTERISTICS LDA10F-5 DERATING CURVE LDA-3