Ordering information AC-DC Power Supplies Open Frame/Enclosed type LEA 50 F -5 -O LEA50F 12345 1Series name R Recommended EMI/EMC Filter 2Output wattage NAC-06-472 3Universal input 4Output voltage 5Optional *6 C :with Coating G :Low leakage current J2:Mini terminal block R :with Remote ON/OFF High voltage pulse noise type : NAP series S :with Chassis Low leakage current type : NAM series SN:with Chassis & cover *The EMI/EMC Filter is recommended Y :with Potentiometer *to connect with several devices. LEA MODEL LEA50F-3R3-Y LEA50F-5 LEA50F-9 LEA50F-12 LEA50F-15 LEA50F-18 LEA50F-24 LEA50F-24-H LEA50F-30 LEA50F-48 MAX OUTPUT WATTAGE W 33 50 50.4 51.6 52.5 50.4 50.4 50.4 51 52.8 5 ( ) DC OUTPUT * 3.3V 10A 5V 10A 9V 5.6A 12V 4.3A 15V 3.5A 18V 2.8A 24V 2.1A 24V 2.1 2.6 A 30V 1.7A 48V 1.1A SPECIFICATIONS MODEL LEA50F-3R3-Y LEA50F-5 LEA50F-9 LEA50F-12 LEA50F-15 LEA50F-18 LEA50F-24 LEA50F-24-H LEA50F-30 LEA50F-48 VOLTAGE V AC85 - 264 1 or DC120 - 370 f ACIN 100V 0.6 0.7typ CURRENT A ACIN 200V 0.3 0.35typ FREQUENCY Hz 50/60 (47-63) or DC ACIN 100V 70typ 75typ 78typ 78typ 79typ 80typ 81typ 81typ 82typ 83typ EFFICIENCY % INPUT ACIN 200V 71typ 77typ 80typ 80typ 81typ 82typ 83typ 83typ 84typ 85typ ACIN 100V 0.98typ 0.99typ POWER FACTOR ACIN 200V 0.91typ 0.93typ ( )( )( ) ACIN 100V 15typ Io=100% At cold start Ta=25 C INRUSH CURRENT A ACIN 200V 30typ (Io=100%)(At cold start)(Ta=25 ) C ( , ) LEAKAGE CURRENT mA 0.75max 60Hz According to IEC60950 and DEN-AN VOLTAGE V 3.3 5 9 12 15 18 24 24 30 48 1 ( ) CURRENT A * 10 10 5.6 4.3 3.5 2.8 2.1 2.1 Peak 2.6 1.7 1.1 LINE REGULATION mV 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max LOAD REGULATION mV 40max 40max 100max 100max 120max 120max 150max 150max 180max 300max 0to+50 *2 80max 80max 120max 120max 120max 120max 120max 120max 120max 150max C RIPPLE mVp-p 2 -10-0 * 140max 140max 160max 160max 160max 160max 160max 160max 160max 200max C 0to+50 *2 120max 120max 150max 150max 150max 150max 150max 150max 150max 350max C RIPPLE NOISE mVp-p 2 OUTPUT -10-0 * 160max 160max 180max 180max 180max 180max 180max 180max 180max 400max C 0to+50 50max 50max 90max 120max 150max 180max 240max 240max 300max 480max C TEMPERATURE REGULATION mV -10 to +50 60max 60max 120max 150max 180max 200max 290max 290max 360max 600max C DRIFT mV *3 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max ( , ) START-UP TIME ms 500max ACIN 100V Io=100% HOLD-UP TIME ms 20typ (Io=100%) ( ) OUTPUT VOLTAGE ADJUSTMENT RANGE V 2.85 - 3.6 Fixedwhich can be adjusted the output is available as optional: 10% t OUTPUT VOLTAGE SETTING V 3.25 - 3.35 4.9 - 5.3 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.5 - 31.5 46.0 - 50.0 ( ) OVERCURRENT PROTECTION Works over 105% of rating works over 105% of peak current at option -H and recovers automatically OVERVOLTAGE PROTECTION 4.00 - 5.25V Works at 115 - 140% of rating PROTECTION CIRCUIT AND OPERATING INDICATION Not provided OTHERS REMOTE SENSING Not provided ( ) REMOTE ON/OFF Option Refer to Instruction Manual INPUT-OUTPUT RC 4 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) - * W , , , ( ) INPUT-FG AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature W ISOLATION OUTPUT RC-FG 4 AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) - * W 4 , , ( ) OUTPUT-RC * AC100V 1minute Cutoff current = 100mA DC100V 10M min At Room Temperature W , , ( )( ), , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE -10 to +70C 20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max , , ( ), , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis , , , , ( ) AGENCY APPROVALS UL60950-1 C-UL EN60950-1 EN60065 EN50178 Complies with DEN-AN and IEC60950-1 At only AC input SAFETY AND , , , NOISE CONDUCTED NOISE Complies with FCC-B CISPR22-B EN55022-B VCCI-B REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 ( ) ( ) CASE SIZE/WEIGHT 55 26 195mm W H D /210g max without chassis and cover X X X X OTHERS COOLING METHOD Convection *1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage. with the input voltage held constant at the rated input/output. *4 Applicable when remote control (optional) is added. *2 This is the value that measured on measuring board with capacitor of 22mF within 150mm *5 ( ):peak current. from output terminal. *6 Please contact us about safety approvals for the model with option. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: * Parallel operation with other model is not possible. RM101). * Derating is required when operated with chassis and cover. *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, LEA-2LEA50F External view Voltage adjust optional ( ) 23 2-3.5 7 4-M3 +0.5 4-3.5 210 - Name plate Mounting Hole Mounting Hole CN3 CN1 RC(-) RC(+) CN3 FG CN2 AC(N) Output(-) AC(L) Output(+) Connector for Remote CN1 ON/OFF (optional) C119 CN2 +0.5 5 185 - 195 225 +0.5 210 7 - LEA 3.5 2-M3 Mounting Hole PCB t=1.6 Weight: 210g or less PIN CONNECTION Optional (Without chassis and cover) I / O Connector Mating Connector Terminal Pin No. Input Pin No. Output Pin No. Remote ON/OFF Tolerance: t1 Chain: SVH-21T-P1.1 1 AC(L) 1 -V CN1 B3P5-VH VHR-5N 1 RC(+) Loose: BVH-21T-P1.1 2 Dimensions in mm. 2 -V CN1 CN2 CN3 Chain: SVH-21T-P1.1 3 AC(N) PCB Material: Glass composite CN2 B4P-VH VHR-4N 3 +V Loose: BVH-21T-P1.1 4 2 RC(-) (CEM3) Chain: SXH-001T-P0.6 4 +V 5 FG CN3 B2B-XH-A XHP-2 Chassis and cover is optional. Loose: BXH-001T-P0.6 Keep drawing current per pin below 5A for CN2 Mounting torque: 0.6N m(6.3kgfcm)max (Mfr: J.S.T.) Performance data ( ) ( ) RISE TIME & FALL TIME LEA50F-5 EFFICIENCY LEA50F-5 80 78 76 74 DC Output 72 AC Input ACIN 100V Io=100% 70 100% Load factor Load factor 50% 68 60 100 140 180 220 260 300 50ms/DIV INPUT VOLTAGE V ( ) ( ) INPUT HARMONIC CURRENT LEA50F-5 INPUT HARMONIC CURRENT LEA50F-5 10 10 Harmonic current standard class A (at odd number) Harmonic current standard class A 1 Load factor 100% 1 (at odd number) Input voltage AC 100V Load factor 100% Input voltage AC 230V 0.1 0.1 0.01 0.01 0.001 0.001 0310 20040 0 10 20 30 40 HARMONIC ORDER HARMONIC ORDER LEA-3 55 max A 3 5 HARMONIC CURRENT +0.5 23 45 - (Lead) 17.5 +0.5 12 40 - + 0.5 20- 22 HARMONIC CURRENT A EFFICIENCY 3.5 15 10 3.5 32 36 65