AC-DC Power Supplies Open Frame/ Enclosed Type Power Cost Rugged Safety EMI OCP OVP World wide Inrush Factor Effective PCB type Approvals current Correction limiting LFP-series Feature EMS Compliance : EN61204-3, EN61000-6-2 High power & peak power EN61000-4-2 Small and compact PCB construction EN61000-4-3 Built-in inrush current, overcurrent and overvoltage protection EN61000-4-4 circuits EN61000-4-5 Harmonic attenuator (Complies with IEC61000-3-2 class A) EN61000-4-6 Universal input (AC85-264V) EN61000-4-8 Power factor correction EN61000-4-11 Safety agency approvals UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN EMI Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, VCCI-B 5-year warranty (refer to Instruction Manual) CE marking Low Voltage Directive RoHS Directive June 26, 2020 LFP-1Ordering information AC-DC Power Supplies Open Frame/ Enclosed Type LF P 100 F -O -O LFP100F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R 2 Single output NAC-04-472 3 Output wattage 4 Universal input 5 Output voltage *1 6 Optional C : with Coating G : Low leakage current J1 : VH(J.S.T.)connector type High voltage pulse noise type : NAP series R : with Remote ON/OFF Low leakage current type : NAM series R2 : with Remote ON/OFF * A higher current rating EMI/EMC filter S : with Chassis may be recommended in view of the SN : with Chassis & cover other devices that could be connected in parallel with the power supply. Please refer to Instruction manual 7. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL LFP100F-24-Y LFP100F-36-Y LFP100F-48-Y MAX OUTPUT WATTAGE W *2 103.2 (206.4) 100.8 (201.6) 100.8 (201.6) DC OUTPUT *2 24V 4.3A (8.6A) 36V 2.8A (5.6A) 48V 2.1A (4.2A) SPECIFICATIONS MODEL LFP100F-24-Y LFP100F-36-Y LFP100F-48-Y VOLTAGE V AC85 - 264 1f (Refer to Derating ,Instruction Manual 1 and 3) *5 ACIN 100V 1.3typ (Io=100%) CURRENT A ACIN 200V 0.7typ (Io=100%) FREQUENCY Hz 50 / 60 (47 - 63) ACIN 100V 84.0typ (Io=100%) 84.0typ (Io=100%) 84.0typ (Io=100%) EFFICIENCY % INPUT ACIN 200V 87.0typ (Io=100%) 87.0typ (Io=100%) 87.0typ (Io=100%) ACIN 100V 0.99typ (Io=100%) POWER FACTOR ACIN 200V 0.95typ (Io=100%) ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) INRUSH CURRENT A ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT mA 0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) VOLTAGE V 24 36 48 *2 CURRENT A 4.3 (Peak 8.6) 2.8 (Peak 5.6) 2.1 (Peak 4.2) LINE REGULATION mV *7 96max 144max 192max LOAD REGULATION mV *7 150max 240max 240max 0 to +50C 120max 150max 150max *3 RIPPLE mVp-p -10 - 0C 160max 200max 200max 0 to +50C 150max 250max 250max *3 RIPPLE NOISE mVp-p OUTPUT -10 - 0C 180max 300max 300max 0 to +50C 240max 360max 480max TEMPERATURE REGULATION mV -10 to +50C 290max 450max 600max *4 DRIFT mV 96max 144max 192max START-UP TIME ms 350typ (ACIN 100V, Io=100%) HOLD-UP TIME ms 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 21.60 to 27.50 32.40 to 39.60 39.60 to 52.80 OUTPUT VOLTAGE SETTING V 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 OVERCURRENT PROTECTION Works over 101% of rating and recovers automatically OVERVOLTAGE PROTECTION V 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 PROTECTION CIRCUIT AND OPERATING INDICATION Not provided OTHERS REMOTE SENSING Not provided REMOTE ON/OFF Option (Refer to Instruction Manual 6) . *6 INPUT-OUTPUT RC AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) ISOLATION . *6 OUTPUT RC-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) *6 OUTPUT-RC AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) *5 OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Derating ,Instruction Manual 3), 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis AGENCY APPROVALS (At only AC input) UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN SAFETY AND NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *8 CASE SIZE/WEIGHT 62X33X155mm 2.44X1.30X6.10 inches (WXHXD) / 290g max (with chassis & cover : 480g max) OTHERS COOLING METHOD Convection (Refer toDeratin ,Instruction Manual 3) *5 *1 Specification is changed at option, ref er to Instruction Manual. Measured b y 20MHz oscilloscope or Ripple-Noise meter *7 Please contact us about dynamic load and input response. *2 P eak loading for 10sec. And Duty 40% max, refer to Instruction (Equivalent to KEISOKU-GIKEN: RM103). *8 Please contact us about another class. Manual 6. In detail. *4 Dr ift is the change in DC output for an eight hour period * To meet the specifications. Do not operate over-loaded condition. ( ) means peak current. There is a possibility that an internal after a half-hour warm-up at 25C, with the input voltage * Parallel operation is not possible. device is damaged when the specification is exceeded. held constant at the rated input/output. * Derating is required when operated with chassis and cover. *3 This is the v alue that measured on measuring board with *5 Derating is required. * Sound noise may be generated by power supply in case of pulse load. capacitor of 22mF at 150mm from output terminal. *6 Applicab le when remote control (optional) is added. June 26, 2020 LFP-2