AC-DC Power Supplies Medical Type Power Cost Rugged Safety EMI OCP OVP Medical World wide Inrush Factor Effective PCB type Approvals electric current Correction equipment limiting LMA-series Feature CE marking For medical electric equipment Low Voltage Directive Internal dual fuses RoHS Directive Low leakage current High power & peak power (option) EMS Compliance : EN61204-3, EN61000-6-2 Small and compact PCB construction IEC60601-1-2 (2014), EN60601-1-2 (2015) Built-in inrush current, overcurrent and overvoltage protection EN61000-4-2 circuits EN61000-4-3 Harmonic attenuator (Complies with IEC61000-3-2 class A) EN61000-4-4 Universal input (AC85-264V) EN61000-4-5 Power factor correction EN61000-4-6 EN61000-4-8 Safety agency approvals EN61000-4-11 ANSI/AAMI ES60601, EN60601-1 3rd EMI Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, VCCI-B 5-year warranty June 29, 2020 LMA-1Ordering information AC-DC Power Supplies Medical Type LM A 100 F -O -O LMA100F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R 2 Single output NAM-04-101 3 Output wattage 4 Universal input 5 Output voltage *1 6 Optional C : with Coating G : Low leakage current H : with the function to be acceptable High voltage pulse noise type : NAP series to output peak current Low leakage current type : NAM series J1 : VH(J.S.T.)connector type * A higher current rating EMI/EMC filter R : with Remote ON/OFF may be recommended in view of the R2 : with Remote ON/OFF other devices that could be connected S : with Chassis in parallel with the power supply. SN : with Chassis & cover P : Setting in the overcurrent protection rating This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL LMA100F-24-Y LMA100F-24-HY MAX OUTPUT WATTAGE W 103.2 103.2 (206.4) *2 DC OUTPUT 24V 4.3A 24V 4.3A (8.6A) *2 SPECIFICATIONS MODEL LMA100F-24-Y LMA100F-24-HY VOLTAGE V AC85 - 264 1f (Refer to Derating ,Instruction Manual 1 and 3) ACIN 100V 1.4typ (Io=100%) CURRENT A ACIN 200V 0.7typ (Io=100%) FREQUENCY Hz 50 / 60 (47 - 63) ACIN 100V 84.0typ (Io=100%) 84.0typ (Io=100%) EFFICIENCY % INPUT ACIN 200V 86.0typ (Io=100%) 86.0typ (Io=100%) ACIN 100V 0.99typ (Io=100%) POWER FACTOR ACIN 200V 0.95typ (Io=100%) ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) INRUSH CURRENT A ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT mA 0.10 / 0.25max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1) VOLTAGE V 24 24 *2 CURRENT A 4.3 4.3 (Peak 8.6) LINE REGULATION mV *7 96max 96max LOAD REGULATION mV *7 150max 150max 0 to +50C 120max 120max *3 RIPPLE mVp-p -10 - 0C 160max 160max 0 to +50C 150max 150max *3 RIPPLE NOISE mVp-p OUTPUT -10 - 0C 180max 180max 0 to +50C 240max 240max TEMPERATURE REGULATION mV -10 to +50C 290max 290max *4 DRIFT mV 96max 96max START-UP TIME ms 350typ (ACIN 100V, Io=100%) HOLD-UP TIME ms 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 19.20 to 27.50 19.20 to 27.50 OUTPUT VOLTAGE SETTING V 24.00 to 24.96 24.00 to 24.96 OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically OVERVOLTAGE PROTECTION V 27.60 to 33.60 27.60 to 33.60 PROTECTION CIRCUIT AND OPERATING INDICATION Not provided OTHERS REMOTE SENSING Not provided REMOTE ON/OFF Option (Required external power source.) . *6 INPUT-OUTPUT RC AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOOP INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOOP ISOLATION . *6 OUTPUT RC-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) *6 OUTPUT-RC AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) *5 OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing), (Refer to Derating, Instruction Manual 3) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis AGENCY APPROVALS (AT ONIY AC input) ANSI/AAMI ES60601-1, EN60601-1 3rd, Complies with IEC60601-1-2 4th Ed. SAFETY AND NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *8 CASE SIZE/WEIGHT 62X33X155mm 2.44X1.30X6.10 inches (WXHXD) / 290g max (with chassis & cover : 470g max) OTHERS COOLING METHOD Convection (Refer to Derating, Instruction Manual 3) *5 *1 Specification is changed at option, ref er to Instruction Manual. *4 Dr ift is the change in DC output for an eight hour period * To meet the specifications. Do not operate over-loaded condition. *2 P eak loading for 10sec. And Duty 40% max. after a half-hour warm-up at 25C, with the input voltage * Parallel operation is not possible. ( ) means peak current. There is a possibility that an internal device held constant at the rated input/output. * Derating is required when operated with chassis and cover. is damaged when the specification is exceeded. *5 Derating is required. * Sound noise may be generated by power supply in case of pulse load. *3 This is the v alue that measured on measuring board with capacitor of *6 Applicab le when remote control (optional) is added. 22mF at 150mm from output terminal. *7 Please contact us about dynamic load and input response . Measured b y 20MHz oscilloscope or Ripple-Noise meter (Equivalent *8 Please contact us about another class . to KEISOKU-GIKEN: RM103). June 29, 2020 LMA-2