H V.ADJ CN1 AC AC (L) (N) FG CN2 CN3 Ordering information AC-DC Power Supplies Enclosed type PBA1000F PBA/PBW PBA/PBW PBA/PBW PB A 1000 F -5 -O PBA1000F 123456 Block diagram 1Series name R Recommended EMI/EMC Filter 2Single output NAC-20-472 3Output wattage 4Universal input 5Output voltage 6Optional *6 C :with Coating FUSE INRUSH AC IN NOISE G :Low leakage current RECTIFIER CURRENT 85 - 264V FILTER LIMIT U :Operation stop voltage 250V30A High voltage pulse noise type : NAP series is set at a lower value Low leakage current type : NAM series F1 :With Long-Life fan *The EMI/EMC Filter is recommended FG F3 :Reverse air exhaust *to connect with several devices. type F4 :Low speed fan RECTIFIER INVERTER DC OUT AND FILTER M THERMAL PROTECTION CURRENT OVER VOLTAGE Refer to instruction manual SENSING PROTECTION 7.1. ACTIVE FILTER MODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48 RECTIFIER CONTROL SWITCHING CONTROL S(REMOTE SENSING) AND MAX OUTPUT WATTAGE W 660 1000 1005 1056 1050 1056 1044 1056 DEVICE FILTER ACIN 100V 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44A 36V 29A 48V 22A RC(REMOTE ON / OFF) DC OUTPUT ACIN 200V*3 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44(51)A 36V 29A 48V 22A MASTER VB(VOLTAGE BALANCE) VOLTAGE CURRENT SLAVE SENSING SENSING CB(CURRENT BALANCE) CONTROL SPECIFICATIONS MODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48 VOLTAGE INTERNAL CONTROL FAN ALARM PG(POWER GOOD) ( ) SENSING REGULATOR VOLTAGE V AC85 - 264 1 or DC120 - 350 AC50 or DC70 Please refer to the instruction manual 7. option 5 f * ACIN 100V 9typ 13typ AUX(12 V 0.1A) CURRENT A ACIN 200V 5typ 7typ ( ) FREQUENCY Hz 50/60 47 - 63 ACIN 100V 74typ 79typ 80typ 82typ 82typ 84typ 84typ 84typ EFFICIENCY % INPUT ACIN 200V 76typ 81typ 83typ 84typ 84typ 86typ 86typ 86typ ACIN 100V 0.98typ (Io=100%) POWER FACTOR ( ) ACIN 200V 0.95typ Io=100% ACIN 100V 20/40typ (Io=100%)(Primary inrush current /Secondary inrush current)(More then 10 sec. to re-start) INRUSH CURRENT A External view ( )( )( ) ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More then 10 sec. to re-start LEAKAGE CURRENT mA 0.5/1.0max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN) VOLTAGE V 3.3 5 7.5 12 15 24 36 48 ACIN 100V 200 200 134 88 70 44 29 22 CURRENT A 3 ( ) 4-M4 ACIN 200V* 200 200 134 88 70 44 51 29 22 M4 Name plate Input terminal cover Mounting Hole LINE REGULATION mV 20max 20max 36max 48max 60max 96max 144max 192max 25max 15.85 (Bottom side) 0.62 0.98 LOAD REGULATION mV 40max 40max 60max 100max 120max 150max 150max 300max 0 to +50 *1 80max 80max 120max 120max 120max 120max 150max 150max C RIPPLE mVp-p 1 AC(L) -20 - 0C* 140max 140max 160max 160max 160max 160max 160max 400max AC(N) 0 to +50 *1 120max 120max 150max 150max 150max 150max 200max 200max C OUTPUT RIPPLE NOISE mVp-p 1 FG( ) -20 - 0C* 160max 160max 180max 180max 180max 180max 240max 500max 0 to +50 40max 50max 75max 120max 150max 240max 360max 480max C TEMPERATURE REGULATION mV Name plate -20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max DRIFT mV *2 12max 20max 30max 48max 60max 96max 144max 192max CN3 Output voltage ( , ) CN2 START-UP TIME ms 400typ ACIN 100/200V Io=100% *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. adjustable potentiometer CN1 HOLD-UP TIME ms 20typ (ACIN 100/200V, Io=100%) LED OUTPUT VOLTAGE ADJUSTMENT RANGE V 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00 OUTPUT VOLTAGE SETTING V 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92 Output terminal(-) OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically Output terminal(+) OVERVOLTAGE PROTECTION V *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0 PROTECTION 51.25 0.5 29 165 ( ) CIRCUIT AND OPERATING INDICATION LED Green 2.02 1.14 6.5 OTHERS (35) 240 6max REMOTE SENSING Provided 1.38 9.45 0.24 REMOTE ON/OFF Provided INPUT-OUTPUT RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50M min (At Room Temperature) - W , , , ( ) INPUT-FG AC2 000V 1minute Cutoff current = 25mA DC500V 50MWmin At Room Temperature ISOLATION OUTPUT RC AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) - - W 8-M4 , , ( ) 2-M4 OUTPUT-RC-AUX AC500V 1minute Cutoff current = 100mA DC500V 50MWmin At Room Temperature Mounting Hole (Both side) OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71 (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max 2-9 C , , ( ) , ( , ) 0.35 STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT AIR FLOW 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN SAFETY AND , , , , NOISE CONDUCTED NOISE Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 *7 0.5 Tolerance : 1 0.04 7 13 29 165 ( )( ) CASE SIZE/WEIGHT 150 61 240mm 5.91 2.4 9.45 inches without terminal block and screw W H D /2.2kg max X X X X X X Weight : 2.2kg max 0.28 0.51 1.14 6.5 OTHERS COOLING METHOD Forced cooling (internal fan) PCB Material/thickness : FR-4 / 1.6mm 0.06 Chassis material : Aluminum *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage Dimensions in mm, = inches :RM101). protection circuit is please contact us for details. Mounting torque : 1.2N m(12.8kgf cm)max Ripple and ripple noise is measured on measuring board with capacitor of 22mF within *5 Derating is required.Consult us for details. Screw tightening torque : 1.6N m(16.9kgf cm)max 150mm from the output terminal. *6 Please contact us about safety approvals for the model with option. The housing for the remote sensing unused is mounted on CN1 *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *7 Please contact us about class C. Please connect safety ground to FG terminal on the unit. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual * A sound may occur from power supply at pulse loading. in detail. PBA/PBW-20 PBA/PBW-20 PBA/PBW-21 (7.5) 13 9 10 0.39 0.51 0.35 0.3 79 3.11 (24) 104.75 0.94 4.12 (18) (25) 2.5 0.71 0.98 0.1 11.5 38 0.5 110 0.5 20 0.45 1.5 4.33 0.79 61 150 2.4 5.91 H V.ADJ CN1 AC AC (L) (N) FG CN2 CN3 Ordering information AC-DC Power Supplies Enclosed type PBA1000F PBA/PBW PBA/PBW PBA/PBW PB A 1000 F -5 -O PBA1000F 123456 Block diagram 1Series name R Recommended EMI/EMC Filter 2Single output NAC-20-472 3Output wattage 4Universal input 5Output voltage 6Optional *6 C :with Coating FUSE INRUSH AC IN NOISE G :Low leakage current RECTIFIER CURRENT 85 - 264V FILTER LIMIT U :Operation stop voltage 250V30A High voltage pulse noise type : NAP series is set at a lower value Low leakage current type : NAM series F1 :With Long-Life fan *The EMI/EMC Filter is recommended FG F3 :Reverse air exhaust *to connect with several devices. type F4 :Low speed fan RECTIFIER INVERTER DC OUT AND FILTER M THERMAL PROTECTION CURRENT OVER VOLTAGE Refer to instruction manual SENSING PROTECTION 7.1. ACTIVE FILTER MODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48 RECTIFIER CONTROL SWITCHING CONTROL S(REMOTE SENSING) AND MAX OUTPUT WATTAGE W 660 1000 1005 1056 1050 1056 1044 1056 DEVICE FILTER ACIN 100V 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44A 36V 29A 48V 22A RC(REMOTE ON / OFF) DC OUTPUT ACIN 200V*3 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44(51)A 36V 29A 48V 22A MASTER VB(VOLTAGE BALANCE) VOLTAGE CURRENT SLAVE SENSING SENSING CB(CURRENT BALANCE) CONTROL SPECIFICATIONS MODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48 VOLTAGE INTERNAL CONTROL FAN ALARM PG(POWER GOOD) ( ) SENSING REGULATOR VOLTAGE V AC85 - 264 1 or DC120 - 350 AC50 or DC70 Please refer to the instruction manual 7. option 5 f * ACIN 100V 9typ 13typ AUX(12 V 0.1A) CURRENT A ACIN 200V 5typ 7typ ( ) FREQUENCY Hz 50/60 47 - 63 ACIN 100V 74typ 79typ 80typ 82typ 82typ 84typ 84typ 84typ EFFICIENCY % INPUT ACIN 200V 76typ 81typ 83typ 84typ 84typ 86typ 86typ 86typ ACIN 100V 0.98typ (Io=100%) POWER FACTOR ( ) ACIN 200V 0.95typ Io=100% ACIN 100V 20/40typ (Io=100%)(Primary inrush current /Secondary inrush current)(More then 10 sec. to re-start) INRUSH CURRENT A External view ( )( )( ) ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More then 10 sec. to re-start LEAKAGE CURRENT mA 0.5/1.0max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN) VOLTAGE V 3.3 5 7.5 12 15 24 36 48 ACIN 100V 200 200 134 88 70 44 29 22 CURRENT A 3 ( ) 4-M4 ACIN 200V* 200 200 134 88 70 44 51 29 22 M4 Name plate Input terminal cover Mounting Hole LINE REGULATION mV 20max 20max 36max 48max 60max 96max 144max 192max 25max 15.85 (Bottom side) 0.62 0.98 LOAD REGULATION mV 40max 40max 60max 100max 120max 150max 150max 300max 0 to +50 *1 80max 80max 120max 120max 120max 120max 150max 150max C RIPPLE mVp-p 1 AC(L) -20 - 0C* 140max 140max 160max 160max 160max 160max 160max 400max AC(N) 0 to +50 *1 120max 120max 150max 150max 150max 150max 200max 200max C OUTPUT RIPPLE NOISE mVp-p 1 FG( ) -20 - 0C* 160max 160max 180max 180max 180max 180max 240max 500max 0 to +50 40max 50max 75max 120max 150max 240max 360max 480max C TEMPERATURE REGULATION mV Name plate -20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max DRIFT mV *2 12max 20max 30max 48max 60max 96max 144max 192max CN3 Output voltage ( , ) CN2 START-UP TIME ms 400typ ACIN 100/200V Io=100% *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. adjustable potentiometer CN1 HOLD-UP TIME ms 20typ (ACIN 100/200V, Io=100%) LED OUTPUT VOLTAGE ADJUSTMENT RANGE V 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00 OUTPUT VOLTAGE SETTING V 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92 Output terminal(-) OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically Output terminal(+) OVERVOLTAGE PROTECTION V *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0 PROTECTION 51.25 0.5 29 165 ( ) CIRCUIT AND OPERATING INDICATION LED Green 2.02 1.14 6.5 OTHERS (35) 240 6max REMOTE SENSING Provided 1.38 9.45 0.24 REMOTE ON/OFF Provided INPUT-OUTPUT RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50M min (At Room Temperature) - W , , , ( ) INPUT-FG AC2 000V 1minute Cutoff current = 25mA DC500V 50MWmin At Room Temperature ISOLATION OUTPUT RC AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) - - W 8-M4 , , ( ) 2-M4 OUTPUT-RC-AUX AC500V 1minute Cutoff current = 100mA DC500V 50MWmin At Room Temperature Mounting Hole (Both side) OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71 (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max 2-9 C , , ( ) , ( , ) 0.35 STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT AIR FLOW 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN SAFETY AND , , , , NOISE CONDUCTED NOISE Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 *7 0.5 Tolerance : 1 0.04 7 13 29 165 ( )( ) CASE SIZE/WEIGHT 150 61 240mm 5.91 2.4 9.45 inches without terminal block and screw W H D /2.2kg max X X X X X X Weight : 2.2kg max 0.28 0.51 1.14 6.5 OTHERS COOLING METHOD Forced cooling (internal fan) PCB Material/thickness : FR-4 / 1.6mm 0.06 Chassis material : Aluminum *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage Dimensions in mm, = inches :RM101). protection circuit is please contact us for details. Mounting torque : 1.2N m(12.8kgf cm)max Ripple and ripple noise is measured on measuring board with capacitor of 22mF within *5 Derating is required.Consult us for details. Screw tightening torque : 1.6N m(16.9kgf cm)max 150mm from the output terminal. *6 Please contact us about safety approvals for the model with option. The housing for the remote sensing unused is mounted on CN1 *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *7 Please contact us about class C. Please connect safety ground to FG terminal on the unit. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual * A sound may occur from power supply at pulse loading. in detail. PBA/PBW-21 PBA/PBW-20 PBA/PBW-21 (7.5) 10 13 9 0.39 0.51 0.35 0.3 79 3.11 (24) 104.75 0.94 4.12 (18) (25) 2.5 0.71 0.98 0.1 11.5 38 0.5 110 0.5 20 0.45 1.5 4.33 0.79 150 61 2.4 5.91