V.ADJ CN1 AC AC (L) (N) NC FG CN2 CN3 Ordering information AC-DC Power Supplies Enclosed type PBA1500F PBA/PBW PBA/PBW PBA/PBW PB A 1500 F -5 -O PBA1500F 123456 Block diagram 1Series name R Recommended EMI/EMC Filter 2Single output NAC-20-472 3Output wattage 4Universal input 5Output voltage 6Optional *6 C :with Coating FUSE INRUSH AC IN NOISE G :Low leakage current RECTIFIER CURRENT 85 - 264V FILTER LIMIT U :Operation stop voltage 250V30A High voltage pulse noise type : NAP series is set at a lower value Low leakage current type : NAM series F1 :With Long-Life fan *The EMI/EMC Filter is recommended FG F3 :Reverse air exhaust *to connect with several devices. type F4 :Low speed fan RECTIFIER INVERTER DC OUT AND FILTER M THERMAL PROTECTION CURRENT OVER VOLTAGE Refer to instruction manual SENSING PROTECTION 7.1. ACTIVE FILTER MODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48 RECTIFIER CONTROL SWITCHING CONTROL S(REMOTE SENSING) AND MAX OUTPUT WATTAGE W 990 1500 1500 1500 1500 1680 1692 1680 DEVICE FILTER ACIN 100V 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 65A 36V 42A 48V 32A RC(REMOTE ON / OFF) DC OUTPUT ACIN 200V*3 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 70(105)A 36V 47(70)A 48V 35A MASTER VB(VOLTAGE BALANCE) VOLTAGE CURRENT SLAVE SENSING SENSING CB(CURRENT BALANCE) CONTROL SPECIFICATIONS MODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48 VOLTAGE INTERNAL CONTROL FAN ALARM PG(POWER GOOD) ( ) SENSING REGULATOR VOLTAGE V AC85 - 264 1 or DC120 - 370 AC50 or DC70 Please refer to the instruction manual 7. option 5 f * ACIN 100V 15typ 19typ AUX(12 V 0.1A) CURRENT A ACIN 200V 8typ 10typ ( ) FREQUENCY Hz 50/60 47 - 63 ACIN 100V 72typ 77typ 81typ 81typ 83typ 84typ 84typ 84typ EFFICIENCY % INPUT ACIN 200V 75typ 81typ 83typ 84typ 86typ 87typ 87typ 87typ ACIN 100V 0.98typ (Io=100%) POWER FACTOR ( ) ACIN 200V 0.95typ Io=100% ACIN 100V 20/40typ (Io=100%)(Primary inrush current /Secondary inrush current)(More than 10 sec. to re-start) INRUSH CURRENT A External view ( )( )( ) ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More than 10 sec. to re-start LEAKAGE CURRENT mA 0.9/1.5max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN) VOLTAGE V 3.3 5 7.5 12 15 24 36 48 ACIN 100V 300 300 200 125 100 65 42 32 CURRENT A 3 ( ) ( ) ACIN 200V* 300 300 200 125 100 70 105 47 70 35 8-M4 Name plate Input terminal cover LINE REGULATION mV 20max 20max 36max 48max 60max 96max 144max 192max 25max 15.85 M4 Mounting Hole 0.98 0.62 LOAD REGULATION mV 40max 40max 60max 100max 120max 150max 150max 300max (Both sides) 0 to +50 *1 80max 80max 120max 120max 120max 120max 150max 150max C RIPPLE mVp-p AC(L) 1 -20 - 0C* 140max 140max 160max 160max 160max 160max 160max 400max AC(N) 0 to +50 *1 120max 120max 150max 150max 150max 150max 200max 200max C OUTPUT RIPPLE NOISE mVp-p NC 1 -20 - 0C* 160max 160max 180max 180max 180max 180max 240max 500max 0 to +50 40max 50max 75max 120max 150max 240max 360max 480max FG( ) C TEMPERATURE REGULATION mV -20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max CN1 DRIFT mV *2 12max 20max 30max 48max 60max 96max 144max 192max CN2 Name plate ( , ) START-UP TIME ms 600typ ACIN 100/200V Io=100% CN3 HOLD-UP TIME ms 20typ (ACIN 100/200V, Io=100%) Output voltage OUTPUT VOLTAGE ADJUSTMENT RANGE V 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00 adjustable potentiometer OUTPUT VOLTAGE SETTING V 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92 LED OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically Output terminal(-) OVERVOLTAGE PROTECTION V *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0 PROTECTION ( ) Output terminal(+) CIRCUIT AND OPERATING INDICATION LED Green OTHERS REMOTE SENSING Provided 51.25 0.5 19 171.5 REMOTE ON/OFF Provided 2.02 0.75 6.75 (45) 268 6max INPUT-OUTPUT RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50M min (At Room Temperature) - W 1.77 10.55 0.24 , , , ( ) INPUT-FG AC2 000V 1minute Cutoff current = 25mA DC500V 50MWmin At Room Temperature ISOLATION OUTPUT RC AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) - - W 8-M4 , , ( ) OUTPUT-RC-AUX AC500V 1minute Cutoff current = 100mA DC500V 50MWmin At Room Temperature 4-M4 Mounting Hole OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71 (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max C (Both sides) 2-9 , , ( ) , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max 0.35 C ENVIRONMENT AIR FLOW 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN SAFETY AND , , , , , NOISE CONDUCTED NOISE Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B additional EMI/EMC Filter required for meeting class B REGULATIONS Tolerance : 1 0.04 HARMONIC ATTENUATOR Complies with IEC61000-3-2 *7 10 0.5 15 19 171.5 Weight : 3.4kg max ( )( ) CASE SIZE/WEIGHT 178 61 268mm 7.01 2.4 10.55 inches without terminal block and screw W H D /3.4kg max 0.39 0.59 0.75 6.75 X X X X X X PCB Material/thickness : FR-4 / 1.6mm 0.06 OTHERS COOLING METHOD Forced cooling (internal fan) Chassis material : Aluminum Dimensions in mm, = inches *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage Mounting torque : 1.2N m(12.8kgf cm)max :RM101). protection circuit is please contact us for details. Screw tightening torque : 1.6N m(16.9kgf cm)max Ripple and ripple noise is measured on measuring board with capacitor of 22mF within *5 Derating is required.Consult us for details. The housing for the remote sensing unused is mounted on CN1 150mm from the output terminal. *6 Please contact us about safety approvals for the model with option. Please connect safety ground to FG terminal on the unit. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *7 Please contact us about class C. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual * A sound may occur from power supply at pulse loading. in detail. PBA/PBW-22 PBA/PBW-22 PBA/PBW-23 (7.5) 10 13 9 0.39 0.51 0.35 0.3 107 4.21 (24) 132 (18) (25) 0.94 5.2 0.71 0.98 4 0.16 0.5 0.5 12.8 11.5 38 152.4 0.45 1.5 6 0.5 178 61 7.01 2.4 V.ADJ CN1 AC AC (L) (N) NC FG CN2 CN3 Ordering information AC-DC Power Supplies Enclosed type PBA1500F PBA/PBW PBA/PBW PBA/PBW PB A 1500 F -5 -O PBA1500F 123456 Block diagram 1Series name R Recommended EMI/EMC Filter 2Single output NAC-20-472 3Output wattage 4Universal input 5Output voltage 6Optional *6 C :with Coating FUSE INRUSH AC IN NOISE G :Low leakage current RECTIFIER CURRENT 85 - 264V FILTER LIMIT U :Operation stop voltage 250V30A High voltage pulse noise type : NAP series is set at a lower value Low leakage current type : NAM series F1 :With Long-Life fan *The EMI/EMC Filter is recommended FG F3 :Reverse air exhaust *to connect with several devices. type F4 :Low speed fan RECTIFIER INVERTER DC OUT AND FILTER M THERMAL PROTECTION CURRENT OVER VOLTAGE Refer to instruction manual SENSING PROTECTION 7.1. ACTIVE FILTER MODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48 RECTIFIER CONTROL SWITCHING CONTROL S(REMOTE SENSING) AND MAX OUTPUT WATTAGE W 990 1500 1500 1500 1500 1680 1692 1680 DEVICE FILTER ACIN 100V 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 65A 36V 42A 48V 32A RC(REMOTE ON / OFF) DC OUTPUT ACIN 200V*3 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 70(105)A 36V 47(70)A 48V 35A MASTER VB(VOLTAGE BALANCE) VOLTAGE CURRENT SLAVE SENSING SENSING CB(CURRENT BALANCE) CONTROL SPECIFICATIONS MODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48 VOLTAGE INTERNAL CONTROL FAN ALARM PG(POWER GOOD) ( ) SENSING REGULATOR VOLTAGE V AC85 - 264 1 or DC120 - 370 AC50 or DC70 Please refer to the instruction manual 7. option 5 f * ACIN 100V 15typ 19typ AUX(12 V 0.1A) CURRENT A ACIN 200V 8typ 10typ ( ) FREQUENCY Hz 50/60 47 - 63 ACIN 100V 72typ 77typ 81typ 81typ 83typ 84typ 84typ 84typ EFFICIENCY % INPUT ACIN 200V 75typ 81typ 83typ 84typ 86typ 87typ 87typ 87typ ACIN 100V 0.98typ (Io=100%) POWER FACTOR ( ) ACIN 200V 0.95typ Io=100% ACIN 100V 20/40typ (Io=100%)(Primary inrush current /Secondary inrush current)(More than 10 sec. to re-start) INRUSH CURRENT A External view ( )( )( ) ACIN 200V 40/40typ Io=100% Primary inrush current /Secondary inrush current More than 10 sec. to re-start LEAKAGE CURRENT mA 0.9/1.5max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN) VOLTAGE V 3.3 5 7.5 12 15 24 36 48 ACIN 100V 300 300 200 125 100 65 42 32 CURRENT A 3 ( ) ( ) ACIN 200V* 300 300 200 125 100 70 105 47 70 35 8-M4 Name plate Input terminal cover LINE REGULATION mV 20max 20max 36max 48max 60max 96max 144max 192max 25max 15.85 M4 Mounting Hole 0.98 0.62 LOAD REGULATION mV 40max 40max 60max 100max 120max 150max 150max 300max (Both sides) 0 to +50 *1 80max 80max 120max 120max 120max 120max 150max 150max C RIPPLE mVp-p AC(L) 1 -20 - 0C* 140max 140max 160max 160max 160max 160max 160max 400max AC(N) 0 to +50 *1 120max 120max 150max 150max 150max 150max 200max 200max C OUTPUT RIPPLE NOISE mVp-p NC 1 -20 - 0C* 160max 160max 180max 180max 180max 180max 240max 500max 0 to +50 40max 50max 75max 120max 150max 240max 360max 480max FG( ) C TEMPERATURE REGULATION mV -20 to +50C 60max 75max 120max 180max 180max 290max 440max 600max CN1 DRIFT mV *2 12max 20max 30max 48max 60max 96max 144max 192max CN2 Name plate ( , ) START-UP TIME ms 600typ ACIN 100/200V Io=100% CN3 HOLD-UP TIME ms 20typ (ACIN 100/200V, Io=100%) Output voltage OUTPUT VOLTAGE ADJUSTMENT RANGE V 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00 adjustable potentiometer OUTPUT VOLTAGE SETTING V 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92 LED OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically Output terminal(-) OVERVOLTAGE PROTECTION V *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0 PROTECTION ( ) Output terminal(+) CIRCUIT AND OPERATING INDICATION LED Green OTHERS REMOTE SENSING Provided 51.25 0.5 19 171.5 REMOTE ON/OFF Provided 2.02 0.75 6.75 (45) 268 6max INPUT-OUTPUT RC AC3,000V 1minute, Cutoff current = 25mA, DC500V 50M min (At Room Temperature) - W 1.77 10.55 0.24 , , , ( ) INPUT-FG AC2 000V 1minute Cutoff current = 25mA DC500V 50MWmin At Room Temperature ISOLATION OUTPUT RC AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) - - W 8-M4 , , ( ) OUTPUT-RC-AUX AC500V 1minute Cutoff current = 100mA DC500V 50MWmin At Room Temperature 4-M4 Mounting Hole OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71 (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max C (Both sides) 2-9 , , ( ) , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max 0.35 C ENVIRONMENT AIR FLOW 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN SAFETY AND , , , , , NOISE CONDUCTED NOISE Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B additional EMI/EMC Filter required for meeting class B REGULATIONS Tolerance : 1 0.04 HARMONIC ATTENUATOR Complies with IEC61000-3-2 *7 10 0.5 15 19 171.5 Weight : 3.4kg max ( )( ) CASE SIZE/WEIGHT 178 61 268mm 7.01 2.4 10.55 inches without terminal block and screw W H D /3.4kg max 0.39 0.59 0.75 6.75 X X X X X X PCB Material/thickness : FR-4 / 1.6mm 0.06 OTHERS COOLING METHOD Forced cooling (internal fan) Chassis material : Aluminum Dimensions in mm, = inches *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage Mounting torque : 1.2N m(12.8kgf cm)max :RM101). protection circuit is please contact us for details. Screw tightening torque : 1.6N m(16.9kgf cm)max Ripple and ripple noise is measured on measuring board with capacitor of 22mF within *5 Derating is required.Consult us for details. The housing for the remote sensing unused is mounted on CN1 150mm from the output terminal. *6 Please contact us about safety approvals for the model with option. Please connect safety ground to FG terminal on the unit. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *7 Please contact us about class C. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual * A sound may occur from power supply at pulse loading. in detail. PBA/PBW-23 PBA/PBW-22 PBA/PBW-23 (7.5) 10 13 9 0.39 0.51 0.35 0.3 107 4.21 (24) 132 (18) (25) 0.94 5.2 4 0.71 0.98 0.16 0.5 0.5 12.8 11.5 38 152.4 6 0.5 0.45 1.5 178 61 7.01 2.4