Ordering information AC-DC Power Supplies Enclosed Type PBA10F PBA/PBW PBA/PBW PBA/PBW PB A 10 F -O -O PBA10F 123456 Block diagram 1Series name R Recommended EMI/EMC Filter 2Single output NAC-06-472 3Output wattage 4Universal input 5Output voltage FUSE 6Optional *5 AC250V C :with Coating 2.5A G :Low leakage current INRUSH RECTIFIER AC IN NOISE E :Low leakage current CURRENT AND High voltage pulse noise type : NAP series and EMI class A 85 - 264V FILTER FILTER Low leakage current type : NAM series LIMIT T :Vertical terminal block *The EMI/EMC Filter is recommended J :Connector type *to connect with several devices. N :with Cover (UL508 is acquired) N1 :with DIN rail and Cover FG V :Output voltage setting potentiometer external- TRANSFORMER ly RECTIFIER CONTROL INVERTER AND DC OUT FILTER Cover is optional MODEL PBA10F-5 PBA10F-12 PBA10F-24 CURRENT MAX OUTPUT WATTAGE W 10 10.8 12 SENSING DC OUTPUT 5V 2A 12V 0.9A 24V 0.5A SPECIFICATIONS Photocoupler MODEL PBA10F-5 PBA10F-12 PBA10F-24 CONTROL ( ) VOLTAGE V AC85 - 264 1f or DC110 - 370 AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage*3 ACIN 100V 0.30typ (Io=100%) CURRENT A Photocoupler ACIN 200V 0.20typ (Io=100%) OVER VOLTAGE FREQUENCY Hz 50/60 (47 - 440) or DC PROTECTION INPUT ACIN 100V 74typ 76typ 77typ EFFICIENCY % ACIN 200V 74typ 76typ 77typ ( ) ACIN 100V 15typ Io=100% INRUSH CURRENT A ( ) ACIN 200V 30typ Io=100% ( , , , ) LEAKAGE CURRENT mA 0.15/0.30max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN External view VOLTAGE V 5 12 24 CURRENT A 2 0.9 0.5 *6 LINE REGULATION mV 20max 48max 96max *6 LOAD REGULATION mV 40max 100max 150max External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details. *1 0 to +50C 80max 120max 120max RIPPLE mVp-p -10 - 0 *1 140max 160max 160max C 0 to +50 *1 120max 150max 150max 18 2.5 C LED RIPPLE NOISE mVp-p 0.71 0.1 Voltage adjust 1 16.52 68 OUTPUT -10 - 0 * 160max 180max 180max C 12.2 1.5 0.65 2.68 0.48 0 to +50 50max 120max 240max Cover name plate C TEMPERATURE REGULATION mV -10 to +50 60max 150max 290max C 2 DRIFT mV * 20max 48max 96max M3 ( , ) START-UP TIME ms 200typ ACIN 100V Io=100% Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. * 2-M3 ( , ) Mounting hole HOLD-UP TIME ms 20typ ACIN 100V Io=100% +V OUTPUT VOLTAGE ADJUSTMENT RANGE V 4.50 - 5.50 10.0 - 13.2 19.2 - 27.0 Cover (option) -V OUTPUT VOLTAGE SETTING V 5.00 - 5.15 12.00 - 12.48 24.00 - 24.96 FG OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically PROTECTION OVERVOLTAGE PROTECTION V 5.75 - 7.00 15.0 - 18.0 30.0 - 37.0 AC(L) CIRCUIT AND ( ) OPERATING INDICATION LED Green OTHERS AC(N) REMOTE ON/OFF None INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) W 15.1 1.5 49.5 0.5 4 Terminal cover ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) 0.59 W 1.95 0.16 Point A:C102 1.5 22.6 , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature W 0.89 Name plate , ( ), ( ) , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE -10 to +71 Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max C 2-M3 , , ( ) , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT Mounting hole 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis ( ) , ( ), , AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN SAFETY AND PBA10F , , , , NOISE CONDUCTED NOISE Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B REGULATIONS ( ) *7 HARMONIC ATTENUATOR Complies with IEC61000-3-2 Not built-in to active filter*4 ( )( ) ( ) CASE SIZE/WEIGHT 31X78X68mm 1.22X3.07X2.68 inches without terminal block WXHXD / 150g max with cover : 180g max Tolerance : 1 0.04 OTHERS Weight : 150g max (with cover : 180g max) 36 0.5 11 COOLING METHOD Convection PCB Material/thickness : CEM3 / 1.6mm 0.06 1.42 0.43 *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *5 Please contact us about safety approvals for the model with option. Chassis material : Electric galvanizing steel board :RM101). *6 Please contact us about dynamic load and input response. Dimensions in mm, = inches *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *7 Please contact us about class C. Mounting torque : 0.6N m(6.3kgf cm)max *3 Derating is required. * Parallel operation with other model is not possible. Screw tightening torque : M3 0.8N m(8.5kgf cm)max *4 When two or more units are used,they may not comply with the harmonic attenuator. Please * Derating is required when operated with cover. Please connect safety ground to the unit in 2-M3 holes. contact us for details. * A sound may occur from power supply at peak loading. PBA/PBW-2 PBA/PBW-2 PBA/PBW-3 PB E.indd 2 15.6.18 5:47:30 PM 70.5 2.78 11.5 9.5 7.5 0.45 0.37 0.3 18 34.5 0.71 1.36 31 78 1.22 3.07 34.5 1.36 Ordering information AC-DC Power Supplies Enclosed Type PBA10F PBA/PBW PBA/PBW PBA/PBW PB A 10 F -O -O PBA10F 123456 Block diagram 1Series name R Recommended EMI/EMC Filter 2Single output NAC-06-472 3Output wattage 4Universal input 5Output voltage FUSE 6Optional *5 AC250V C :with Coating 2.5A G :Low leakage current INRUSH RECTIFIER AC IN NOISE E :Low leakage current CURRENT AND High voltage pulse noise type : NAP series and EMI class A 85 - 264V FILTER FILTER Low leakage current type : NAM series LIMIT T :Vertical terminal block *The EMI/EMC Filter is recommended J :Connector type *to connect with several devices. N :with Cover (UL508 is acquired) N1 :with DIN rail and Cover FG V :Output voltage setting potentiometer external- TRANSFORMER ly RECTIFIER CONTROL INVERTER AND DC OUT FILTER Cover is optional MODEL PBA10F-5 PBA10F-12 PBA10F-24 CURRENT MAX OUTPUT WATTAGE W 10 10.8 12 SENSING DC OUTPUT 5V 2A 12V 0.9A 24V 0.5A SPECIFICATIONS Photocoupler MODEL PBA10F-5 PBA10F-12 PBA10F-24 CONTROL ( ) VOLTAGE V AC85 - 264 1f or DC110 - 370 AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage*3 ACIN 100V 0.30typ (Io=100%) CURRENT A Photocoupler ACIN 200V 0.20typ (Io=100%) OVER VOLTAGE FREQUENCY Hz 50/60 (47 - 440) or DC PROTECTION INPUT ACIN 100V 74typ 76typ 77typ EFFICIENCY % ACIN 200V 74typ 76typ 77typ ( ) ACIN 100V 15typ Io=100% INRUSH CURRENT A ( ) ACIN 200V 30typ Io=100% ( , , , ) LEAKAGE CURRENT mA 0.15/0.30max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN External view VOLTAGE V 5 12 24 CURRENT A 2 0.9 0.5 *6 LINE REGULATION mV 20max 48max 96max *6 LOAD REGULATION mV 40max 100max 150max External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details. *1 0 to +50C 80max 120max 120max RIPPLE mVp-p -10 - 0 *1 140max 160max 160max C 0 to +50 *1 120max 150max 150max 18 2.5 C LED RIPPLE NOISE mVp-p 0.71 0.1 Voltage adjust 1 16.52 68 OUTPUT -10 - 0 * 160max 180max 180max C 12.2 1.5 0.65 2.68 0.48 0 to +50 50max 120max 240max Cover name plate C TEMPERATURE REGULATION mV -10 to +50 60max 150max 290max C 2 DRIFT mV * 20max 48max 96max M3 ( , ) START-UP TIME ms 200typ ACIN 100V Io=100% Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. * 2-M3 ( , ) Mounting hole HOLD-UP TIME ms 20typ ACIN 100V Io=100% +V OUTPUT VOLTAGE ADJUSTMENT RANGE V 4.50 - 5.50 10.0 - 13.2 19.2 - 27.0 Cover (option) -V OUTPUT VOLTAGE SETTING V 5.00 - 5.15 12.00 - 12.48 24.00 - 24.96 FG OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically PROTECTION OVERVOLTAGE PROTECTION V 5.75 - 7.00 15.0 - 18.0 30.0 - 37.0 AC(L) CIRCUIT AND ( ) OPERATING INDICATION LED Green OTHERS AC(N) REMOTE ON/OFF None INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) W 15.1 1.5 49.5 0.5 4 Terminal cover ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) 0.59 W 1.95 0.16 Point A:C102 1.5 22.6 , , ( ) OUTPUT-FG AC500V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature W 0.89 Name plate , ( ), ( ) , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE -10 to +71 Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max C 2-M3 , , ( ) , ( , ) STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75 20 - 90%RH Non condensing 9 000m 30 000feet max C ENVIRONMENT Mounting hole 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once each X Y and Z axis ( ) , ( ), , AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN SAFETY AND PBA10F , , , , NOISE CONDUCTED NOISE Complies with FCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B REGULATIONS ( ) *7 HARMONIC ATTENUATOR Complies with IEC61000-3-2 Not built-in to active filter*4 ( )( ) ( ) CASE SIZE/WEIGHT 31X78X68mm 1.22X3.07X2.68 inches without terminal block WXHXD / 150g max with cover : 180g max Tolerance : 1 0.04 OTHERS Weight : 150g max (with cover : 180g max) 36 0.5 11 COOLING METHOD Convection PCB Material/thickness : CEM3 / 1.6mm 0.06 1.42 0.43 *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *5 Please contact us about safety approvals for the model with option. Chassis material : Electric galvanizing steel board :RM101). *6 Please contact us about dynamic load and input response. Dimensions in mm, = inches *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *7 Please contact us about class C. Mounting torque : 0.6N m(6.3kgf cm)max *3 Derating is required. * Parallel operation with other model is not possible. Screw tightening torque : M3 0.8N m(8.5kgf cm)max *4 When two or more units are used,they may not comply with the harmonic attenuator. Please * Derating is required when operated with cover. Please connect safety ground to the unit in 2-M3 holes. contact us for details. * A sound may occur from power supply at peak loading. PBA/PBW-3 PBA/PBW-2 PBA/PBW-3 PB E.indd 3 15.6.18 5:47:31 PM 70.5 2.78 11.5 9.5 7.5 0.45 0.37 0.3 18 34.5 0.71 1.36 31 78 1.22 3.07 34.5 1.36