Ordering information AC-DC Power Supplies Enclosed Type PB A 300 F -5 -O PBA300F 1 2 3 4 5 6 1 Ser ies name Example recommended EMI/EMC filter R 2 Single output NAC-06-472 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *5 C : with Coating G : Lo w leakage current U : Oper ation stop voltage High voltage pulse noise type : NAP series is set at a lower value Low leakage current type : NAM series F3 : Re verse air exhaust * A higher current rating EMI/EMC filter type may be recommended in view of the F4 : Lo w speed fan other devices that could be connected in parallel with the power supply. N1 :with DIN rail Refer to instruction manual 7.1. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48 MAX OUTPUTWATTAGE W 198 300 300 324 330 336 324 336 ACIN 100V 3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14A 36V 9A 48V7A DC OUTPUT 3 ( ) ACIN 200V* 3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V14 16.5 A 36V 9A 48V7A SPECIFICATIONS MODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48 ( ) VOLTAGE V AC85 - 264 1f or DC120- 350 AC50 or DC70 Please refer to the instructionmanual7. option*4 ACIN 100V 3typ 4.1typ CURRENT A ACIN 200V 1.6typ 2typ ( ) FREQUENCY Hz 50/60 47 -63 ACIN 100V 68typ 74typ 76typ 78typ 78typ 79typ 81typ 79typ EFFICIENCY % INPUT ACIN 200V 71typ 77typ 79typ 81typ 81typ 82typ 84typ 82typ ( ) ACIN 100V 0.98typ Io=100% POWER FACTOR ( ) ACIN 200V 0.95typ Io=100% ( )( )( ) ACIN 100V 20/40typ Io=100% Primary inrush current /Secondary inrush current More then3 sec. to re-start INRUSH CURRENT A ACIN 200V 40/40typ (Io=100%)(Primary inrush current /Secondary inrush current)(More then3 sec. to re-start) ( , , , ) LEAKAGE CURRENT mA 0.45/0.75max ACIN 100V/240V 60Hz Io=100% Accordingto IEC60950-1 DENAN VOLTAGE V 3.3 5 7.5 12 15 24 36 48 ACIN 100V 60 60 40 27 22 14 97 CURRENT A ACIN 200V*3 60 60 40 27 22 14(16.5) 97 LINE REGULATION mV 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION mV 40max 40max 60max 100max 120max 150max 150max 300max 1 0to +50C* 80max 80max 120max 120max 120max 120max 150max 150max RIPPLE mVp-p -20 -0 *1 140max 140max 160max 160max 160max 160max 160max 400max C 1 0to +50C* 120max 120max 150max 150max 150max 150max 200max 200max OUTPUT RIPPLE NOISE mVp-p -20 -0 *1 160max 160max 180max 180max 180max 180max 240max 500max C 0to +50C 40max 50max 75max 120max 150max 240max 360max 480max TEMPERATURE REGULATION mV -20to +50 60max 75max 120max 180max 180max 290max 440max 600max C 2 DRIFT mV * 12max 20max 30max 48max 60max 96max 144max 192max START-UP TIME ms 300typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minuteof applying input again from turningoff the input voltage. * ( , ) HOLD-UP TIME ms 20typ ACIN 100/200V Io=100% OUTPUTVOLTAGE ADJUSTMENT RANGE V 2.64- 3.96 3.96 - 6.00 5.25 - 8.25 8.25- 13.20 10.50- 16.50 16.50 - 26.40 25.20 - 39.60 38.40- 56.00 OUTPUTVOLTAGE SETTING V 3.30- 3.40 5.00 - 5.15 7.50 - 7.80 12.00- 12.48 15.00- 15.60 24.00 - 24.96 36.00 - 37.44 48.00- 49.92 OVERCURRENT PROTECTION Worksover 105% of rated currentor 101% of peak current and recovers automatically OVERVOLTAGE PROTECTION V 4.3 - 6.3 6.5 - 8.0 9.0 - 11.6 14.4- 18.6 18.0 - 23.3 28.8 - 37.2 43.2 - 54.0 57.6- 80.0 PROTECTION CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Provided REMOTE ON/OFF Provided , , , ( ) INPUT-OUTPUT-RC AC3 000V1minute Cutoff current= 10mA DC500V 50MWmin At Room Temperature INPUT-FG AC2,000V1minute, Cutoff current= 10mA, DC500V 50M min (At Room Temperature) W ISOLATION , , ( ) OUTPUT-RC-AUX-FG AC500V1minute Cutoff current= 100mA DC500V 50MWmin At Room Temperature OUTPUT-RC AUX AC500V1minute, Cutoff current= 100mA, DC500V 50M min (At Room Temperature) - W , ( ), ( ) , ( , ) OPERATING TEMP.HUMID.ANDALTITUDE -20 to +71C Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max STORAGE TEMP.,HUMID.ANDALTITUDE -20 to +75 , 20 - 90%RH (Non condensing) 9,000m (30,000feet) max C ENVIRONMENT , 2 ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each alongX Yand Z axis 2 IMPACT 196.1m/s (20G), 11ms, once eachX, Y and Z axis ( ) , ( ), , AGENCY APPROVALS At onlyACinput UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178Complieswith DEN-AN SAFETYAND NOISE CONDUCTEDNOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS *6 HARMONICATTENUATOR Complies with IEC61000-3-2 CASE SIZE/WEIGHT 102 42 170mm 4.02 1.65 6.69 inches (without terminalblockand screw)(W H D) /1.0kg max X X X X X X OTHERS ( ) COOLINGMETHOD Forced cooling internal fan *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *5 Please contact us about saf ety approvals for the model with option. :RM101). *6 Please contact us about class C . *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. * A sound ma y occur from power supply at pulse loading. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. *4 Derating is required.Consult us for details. PBA/PBW-16H V.ADJ PBA300F Block diagram FUSE INRUSH AC IN NOISE RECTIFIER CURRENT 85 - 264V FILTER LIMIT 250V10A FG RECTIFIER INVERTER DC OUT AND FILTER M THERMAL PROTECTION CURRENT OVER VOLTAGE SENSING PROTECTION ACTIVE FILTER RECTIFIER CONTROL SWITCHING CONTROL S(REMOTE SENSING) AND DEVICE FILTER RC(REMOTE ON / OFF) MASTER VB(VOLTAGE BALANCE) VOLTAGE CURRENT SLAVE SENSING SENSING CB(CURRENT BALANCE) CONTROL VOLTAGE INTERNAL CONTROL FAN ALARM PG(POWER GOOD) SENSING REGULATOR AUX(12 V 0.1A) External view 4-M4 Mounting Hole 0.5 54 74 2.13 2.91 2-M4 Name plate (14) 25max Mounting Hole M4 Terminal cover 0.55 0.98 (Bottom side) AC(L) AC(N) FG( ) Output terminal(-) Output terminal(+) M4 CN3 CN2 Name plate (15.5) 0.5 28.5 64 CN1 1.12 2.52 0.61 1706max (30) 6.69 0.24 LED 1.18 Output voltage adjustable potentiometer AIR FLOW Tolerance : 1 0.04 Weight : 1.0kg max PCB Material/thickness : FR-4 / 1.6mm 0.06 Chassis material : Aluminum Dimensions in mm, = inches Mounting torque : 1.2N m max Screw tightening torque : 1.6N m max The housing for the remote sensing unused is mounted on CN1 Please connect safety ground to FG terminal on the unit. PBA/PBW-17 (6) 10 7 0.39 0.28 0.24 8.6 0.34 12 (50) 0.47 1.97 (23.5) 0.93 (75) 12 2.95 0.47 (87) 3.43 0.5 42 50.5 20 12 1.99 1.65 0.79 0.47 102 4.02