Ordering information
AC-DC Power Supplies Enclosed Type
PB A 10 F -O -O
PBA10F
1 2 3 4 5 6
1 Ser ies name
Example recommended EMI/EMC filter
R
2 Single output
NAC-06-472
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
C : with Coating
G : Low leakage current
E : Low leakage current
High voltage pulse noise type : NAP series
and EMI class A
Low leakage current type : NAM series
T : V ertical terminal block
* A higher current rating EMI/EMC filter
J : Connector type
may be recommended in view of the
N : with Cover
other devices that could be connected
in parallel with the power supply. (UL508 is acquired)
N1 : with DIN rail and Cover
V : Output voltage setting
potentiometer external-
ly
Cover is optional
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
MODEL PBA10F-5 PBA10F-12 PBA10F-24
MAX OUTPUTWATTAGE[W] 10 10.8 12
DC OUTPUT 5V 2A 12V 0.9A 24V 0.5A
SPECIFICATIONS
MODEL PBA10F-5 PBA10F-12 PBA10F-24
( )
VOLTAGE[V] AC85 -264 1 or DC110- 370 AC50 or DC70 Please refer to the instruction manual 2.1 Inputvoltage 3
f *
( )
ACIN 100V 0.30typ Io=100%
CURRENT[A]
( )
ACIN 200V 0.20typ Io=100%
( )
FREQUENCY[Hz] 50/60 47- 440 or DC
INPUT ACIN 100V 74typ 76typ 77typ
EFFICIENCY[%]
ACIN 200V 74typ 76typ 77typ
ACIN 100V 15typ (Io=100%)
INRUSH CURRENT[A]
ACIN 200V 30typ (Io=100%)
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, Accordingto IEC60950-1,DENAN)
VOLTAGE[V] 51224
CURRENT[A] 2 0.9 0.5
6
LINE REGULATION[mV] * 20max 48max 96max
6
LOAD REGULATION[mV] * 40max 100max 150max
1
0to +50 * 80max 120max 120max
C
RIPPLE[mVp-p]
1
-10- 0 * 140max 160max 160max
C
*1
0to +50 120max 150max 150max
C
RIPPLE NOISE[mVp-p]
*1
OUTPUT -10- 0C 160max 180max 180max
0to +50C 50max 120max 240max
TEMPERATURE REGULATION[mV]
-10to +50 60max 150max 290max
C
DRIFT[mV] *2 20max 48max 96max
START-UP TIME[ms] 200typ(ACIN 100V, Io=100%) Start-up time is 700mstyp forlessthan 1minute of applying input again from turning off the inputvoltage.
*
HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)
OUTPUTVOLTAGE ADJUSTMENT RANGE[V] 4.50- 5.50 10.0- 13.2 19.2 - 27.0
OUTPUTVOLTAGE SETTING[V] 5.00- 5.15 12.00 - 12.48 24.00- 24.96
OVERCURRENT PROTECTION Worksover 105%ofrated current and recovers automatically
PROTECTION
OVERVOLTAGE PROTECTION[V] 5.75- 7.00 15.0- 18.0 30.0 - 37.0
CIRCUIT AND
( )
OPERATING INDICATION LED Green
OTHERS
REMOTE ON/OFF None
, , , ( )
INPUT-OUTPUT AC3 000V 1minute Cutoff current= 10mA DC500V 50MWmin At Room Temperature
, , , ( )
ISOLATION INPUT-FG AC2 000V 1minute Cutoff current= 10mA DC500V 50MWmin At Room Temperature
, , ( )
OUTPUT-FG AC500V1minute Cutoff current= 25mA DC500V 50MWmin At Room Temperature
OPERATINGTEMP.,HUMID.ANDALTITUDE -10 to +71 (Required Derating), 20- 90%RH (Non condensing) 3,000m (10,000feet) max
C
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75 , 20- 90%RH (Non condensing) 9,000m (30,000feet) max
C
ENVIRONMENT
2
VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y andZ axis
2
( ), , ,
IMPACT 196.1m/s 20G 11ms once eachX Y and Z axis
( ) , ( ), ,
AGENCY APPROVALS At onlyACinput UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN
SAFETY AND
, , , ,
NOISE CONDUCTED NOISE Complies withFCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B
REGULATIONS
( ) 7
HARMONICATTENUATOR Complies with IEC61000-3-2 Notbuilt-into active filter 4 *
*
( )( ) ( )
CASE SIZE/WEIGHT 31 78 68mm [1.22 3.07 2.68 inches] without terminalblock W H D / 150g max with cover : 180g max
X X X X X X
OTHERS
COOLING METHOD Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *5 Please contact us about saf ety approvals for the model with option.
:RM101). *6 Please contact us about dynamic load and input response .
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *7 Please contact us about class C .
*3 Derating is required. * P arallel operation with other model is not possible.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please * Der ating is required when operated with cover.
contact us for details. * A sound ma y occur from power supply at peak loading.
PBA/PBW-2PBA10F
Block diagram
FUSE
AC250V
2.5A
INRUSH
RECTIFIER
AC IN NOISE
CURRENT AND
FILTER
85 - 264V
FILTER
LIMIT
FG
TRANSFORMER
RECTIFIER
CONTROL INVERTER AND
DC OUT
FILTER
CURRENT
SENSING
Photocoupler
CONTROL
Photocoupler
OVER VOLTAGE
PROTECTION
External view
External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
18 2.5
LED
[0.71] [0.1]
Voltage adjust
16.52 68
1.5
12.2
[0.65] [2.68]
[0.48]
Cover name plate
M3
2-M3
Mounting hole
+V
Cover (option)
-V
FG
AC(L)
AC(N)
15.11.5
0.5
49.5 4
Terminal cover
[0.59]
[1.95] [0.16]
Point A:C102
1.5
22.6
[0.89]
Name plate
2-M3
Mounting hole
PBA10F
Tolerance : 1 [0.04]
0.5
Weight : 150g max (with cover : 180g max) 36 11
[1.42] [0.43]
PCB Material/thickness : CEM3 / 1.6mm [0.06]
Chassis material : Electric galvanizing steel board
Dimensions in mm, [ ]= inches
Mounting torque : 0.6N m(6.3kgf cm)max
Screw tightening torque : M3 0.8N m(8.5kgf cm)max
Please connect safety ground to the unit in 2-M3 holes.
PBA/PBW-3
70.5
[2.78]
11.5 9.5 7.5
[0.45] [0.37] [0.3]
18 34.5
[0.71] [1.36]
31 78
[3.07]
[1.22]
34.5
[1.36]