Ordering information AC-DC Power Supplies Enclosed type PBW50F PBA/PBW PBA/PBW PBA/PBW PB W 50 F -O -O PBW50F 123456 Block diagram 1Series name R Recommended EMI/EMC Filter 2Dual output NAC-06-472 3Output wattage 4Universal input 5Output voltage FUSE 6Optional *9 250V2A INRUSH C :with Coating NOISE AC IN 85 - 264V RECTIFIER CURRENT G :Low leakage current FILTER LIMIT (0.15mA max / ACIN 240V) High voltage pulse noise type : NAP series E :Low leakage current Low leakage current type : NAM series FG and EMI class A *The EMI/EMC Filter is recommended (0.5mA max / ACIN 240V) *to connect with several devices. T :Vertical terminal block J :Connector type R :with Remote ON/OFF N :with Cover CURRENT N1 :with DIN rail OPTION SENSING V :Output voltage setting RC potentiometer external- ly EXTERNAL E BOOSTER CURRENT SOURCE INDUCTOR SENSING Cover is optional RECTIFIER CONTROL CONTROL AND FILTER MODEL PBW50F-5 PBW50F-12 PBW50F-15 6 OVER VOLTAGE MAX OUTPUT WATTAGE W * 30 50.4 51 INVERTER PROTECTION VOLTAGE V *8 5 ( +10 ) 12 ( +24 ) 15 ( +30 ) t t t INVERTER DC OUTPUT CURRENT1 A 3.0 2.1 1.7 CURRENT2 A *6 4.0 2.7 2.4 RECTIFIER CONTROL AND +DC OUT SPECIFICATIONS FILTER MODEL PBW50F-5 PBW50F-12 PBW50F-15 RECTIFIER ( ) TRANSFORMER VOLTAGE V AC85 - 264 1 or DC120 - 370 AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage 3 f * AND -DC OUT ( ) ( ) ACIN 100V 0.45typ CURRENT1 0.70typ CURRENT1 FILTER CURRENT A ( ) ( ) ACIN 200V 0.30typ CURRENT1 0.40typ CURRENT1 ( ) FREQUENCY Hz 50/60 47 - 63 ( ) ( ) ( ) ACIN 100V 76typ CURRENT1 81typ CURRENT1 81typ CURRENT1 EFFICIENCY % ( ) ( ) ( ) INPUT ACIN 200V 77typ CURRENT1 83typ CURRENT1 83typ CURRENT1 ACIN 100V 0.98typ 0.99typ POWER FACTOR(Io=100%) ACIN 200V 0.87typ 0.93typ External view ( )( ) ACIN 100V 15typ CURRENT1 At cold start INRUSH CURRENT A ( )( ) ACIN 200V 30typ CURRENT1 At cold start ( , , , ) LEAKAGE CURRENT mA 0.40/0.75max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN ( ) ( ) ( ) VOLTAGE V t5 / +10V reference number t12 / +24V reference number t15 / +30V reference number External size of option T,J,R,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details. CURRENT1 A 3.0 / 3.0 2.1 / 2.1 1.7 / 1.7 6 CURRENT2 A * 4.0 / - 2.7 / - 2.4 / - CN3 LINE REGULATION mV 20max / 36max 48max / 96max 60max / 96max (20) Connector for Remote ON/OFF (option) 4 0.79 LOAD REGULATION 1 mV * 250max / 100max 600max / 150max 600max / 150max (16.5) 120 LED (11) LOAD REGULATION 2 mV *5 500max / - 750max / - 750max / - 0.65 4.72 Voltage adjust 0.43 1 0 to +50C* 80max / 240max 120max / 240max 120max / 240max Cover name plate RIPPLE mVp-p -10 - 0 *1 140max / 320max 160max / 320max 160max / 320max 1 2 C 1 OUTPUT 0 to +50C* 120max / 300max 150max / 300max 150max / 300max RIPPLE NOISE mVp-p -10 - 0 *1 160max / 360max 180max / 360max 180max / 360max C M3 +V 0 to +50C 50max 120max 150max TEMPERATURE REGULATION mV -10 to +50 60max 150max 180max C COM 2 DRIFT mV * 20max 48max 60max Cover (option) -V START-UP TIME ms 350typ(ACIN 100V, Io=100%) ( , ) HOLD-UP TIME ms 20typ ACIN 100V Io=100% FG A OUTPUT VOLTAGE ADJUSTMENT RANGE V 4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted) 2-M3 ( ) ( ) ( ) AC(L) OUTPUT VOLTAGE SETTING V 4.99 - 5.30 +V and -V CURRENT1 11.5 - 12.5 +V and -V CURRENT1 14.4 - 15.6 +V and -V CURRENT1 Point A Mounting hole OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically AC(N) PROTECTION OVERVOLTAGE PROTECTION V 6.90 - 10.0 16.8 - 24.0 20.0 - 29.0 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS ( ) REMOTE ON/OFF Optional Required external power source 77 0.5 4 (14) 3.03 0.16 INPUT-OUTPUT RC *7 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) - W 0.55 Terminal cover , , , ( ) (21.5) ISOLATION INPUT-FG AC2 000V 1minute Cutoff current = 10mA DC500V 50MW min At Room Temperature 0.85 OUTPUT RC-FG *7 AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) - W Connector type Name plate 2-M3 , ( ), ( ) , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE -10 to +71C Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max Mounting hole CN3 Option (Mfr : J.S.T.) STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75 , 20 - 90%RH (Non condensing) 9,000m (30,000feet) max C ENVIRONMENT Pin No. Contents 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 1 RC(+) 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis 2 RC(-) ( ) , ( ), , AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN SAFETY AND PBW50F NOISE CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS *10 HARMONIC ATTENUATOR Complies with IEC61000-3-2 Barrier strip type Tolerance : 1 0.04 CASE SIZE/WEIGHT 31 82 120mm 1.22 3.23 4.72 inches (without terminal block)(W H D) / 280g max (with cover : 325g max) X X X X X X OTHERS Weight : 280g max (with cover : 325g max) Model B2B-XH-A COOLING METHOD Convection 88 0.5 11 PCB Material/thickness : CEM3 / 1.6mm 0.06 Mating Connector (Terminal) 3.46 0.43 *1 Measured by 20MHz oscilloscope or Ripple-Noise *5 Figures for 0 to rated current 2.The current not measured *9 Please contact us about safety approvals for the model with Chassis material : Aluminum XHP-2 meter(equivalent to KEISOKU-GIKEN : RM101). side is fixed. option. Dimensions in mm, = inches BXH-001T-P0.6 *2 Drift is the change in DC output for an eight hour period *6 The sum of +power -power must be less than output power. *10Please contact us about class C. Mounting torque : 0.49N m(5kgf cm)max () or SXH-001T-P0.6 after a half-hour warm-up at 25C. *7 RC is applied to remote ON/OFF option. RC is isolated with * Parallel operation with other model is not possible. Screw tightening torque : M3 0.8N m(8.5kgf cm)max *3 Derating is required. input/output and FG. * Derating is required when operated with cover. Please connect safety ground to the unit in 2-M3 holes. *4 Figures for 0 to rated current 1.The current not measured *8 t5,t12,t15 can be used as +10,+24 and +30. * A sound may occur from power supply at peak loading. side is fixed. PBA/PBW-30 PBA/PBW-30 PBA/PBW-31 (71) 2.8 (12) 9.5 7.5 0.47 0.37 0.3 18 35 0.71 1.38 0.5 31 82 1.22 3.23 0.02 34.5 1.36 Ordering information AC-DC Power Supplies Enclosed type PBW50F PBA/PBW PBA/PBW PBA/PBW PB W 50 F -O -O PBW50F 123456 Block diagram 1Series name R Recommended EMI/EMC Filter 2Dual output NAC-06-472 3Output wattage 4Universal input 5Output voltage FUSE 6Optional *9 250V2A INRUSH C :with Coating NOISE AC IN 85 - 264V RECTIFIER CURRENT G :Low leakage current FILTER LIMIT (0.15mA max / ACIN 240V) High voltage pulse noise type : NAP series E :Low leakage current Low leakage current type : NAM series FG and EMI class A *The EMI/EMC Filter is recommended (0.5mA max / ACIN 240V) *to connect with several devices. T :Vertical terminal block J :Connector type R :with Remote ON/OFF N :with Cover CURRENT N1 :with DIN rail OPTION SENSING V :Output voltage setting RC potentiometer external- ly EXTERNAL E BOOSTER CURRENT SOURCE INDUCTOR SENSING Cover is optional RECTIFIER CONTROL CONTROL AND FILTER MODEL PBW50F-5 PBW50F-12 PBW50F-15 6 OVER VOLTAGE MAX OUTPUT WATTAGE W * 30 50.4 51 INVERTER PROTECTION VOLTAGE V *8 5 ( +10 ) 12 ( +24 ) 15 ( +30 ) t t t INVERTER DC OUTPUT CURRENT1 A 3.0 2.1 1.7 CURRENT2 A *6 4.0 2.7 2.4 RECTIFIER CONTROL AND +DC OUT SPECIFICATIONS FILTER MODEL PBW50F-5 PBW50F-12 PBW50F-15 RECTIFIER ( ) TRANSFORMER VOLTAGE V AC85 - 264 1 or DC120 - 370 AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage 3 f * AND -DC OUT ( ) ( ) ACIN 100V 0.45typ CURRENT1 0.70typ CURRENT1 FILTER CURRENT A ( ) ( ) ACIN 200V 0.30typ CURRENT1 0.40typ CURRENT1 ( ) FREQUENCY Hz 50/60 47 - 63 ( ) ( ) ( ) ACIN 100V 76typ CURRENT1 81typ CURRENT1 81typ CURRENT1 EFFICIENCY % ( ) ( ) ( ) INPUT ACIN 200V 77typ CURRENT1 83typ CURRENT1 83typ CURRENT1 ACIN 100V 0.98typ 0.99typ POWER FACTOR(Io=100%) ACIN 200V 0.87typ 0.93typ External view ( )( ) ACIN 100V 15typ CURRENT1 At cold start INRUSH CURRENT A ( )( ) ACIN 200V 30typ CURRENT1 At cold start ( , , , ) LEAKAGE CURRENT mA 0.40/0.75max ACIN 100V/240V 60Hz Io=100% According to IEC60950-1 DENAN ( ) ( ) ( ) VOLTAGE V t5 / +10V reference number t12 / +24V reference number t15 / +30V reference number External size of option T,J,R,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details. CURRENT1 A 3.0 / 3.0 2.1 / 2.1 1.7 / 1.7 6 CURRENT2 A * 4.0 / - 2.7 / - 2.4 / - CN3 LINE REGULATION mV 20max / 36max 48max / 96max 60max / 96max (20) Connector for Remote ON/OFF (option) 4 0.79 LOAD REGULATION 1 mV * 250max / 100max 600max / 150max 600max / 150max (16.5) 120 LED (11) LOAD REGULATION 2 mV *5 500max / - 750max / - 750max / - 0.65 4.72 Voltage adjust 0.43 1 0 to +50C* 80max / 240max 120max / 240max 120max / 240max Cover name plate RIPPLE mVp-p -10 - 0 *1 140max / 320max 160max / 320max 160max / 320max 1 2 C 1 OUTPUT 0 to +50C* 120max / 300max 150max / 300max 150max / 300max RIPPLE NOISE mVp-p -10 - 0 *1 160max / 360max 180max / 360max 180max / 360max C M3 +V 0 to +50C 50max 120max 150max TEMPERATURE REGULATION mV -10 to +50 60max 150max 180max C COM 2 DRIFT mV * 20max 48max 60max Cover (option) -V START-UP TIME ms 350typ(ACIN 100V, Io=100%) ( , ) HOLD-UP TIME ms 20typ ACIN 100V Io=100% FG A OUTPUT VOLTAGE ADJUSTMENT RANGE V 4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted) 2-M3 ( ) ( ) ( ) AC(L) OUTPUT VOLTAGE SETTING V 4.99 - 5.30 +V and -V CURRENT1 11.5 - 12.5 +V and -V CURRENT1 14.4 - 15.6 +V and -V CURRENT1 Point A Mounting hole OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically AC(N) PROTECTION OVERVOLTAGE PROTECTION V 6.90 - 10.0 16.8 - 24.0 20.0 - 29.0 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS ( ) REMOTE ON/OFF Optional Required external power source 77 0.5 4 (14) 3.03 0.16 INPUT-OUTPUT RC *7 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) - W 0.55 Terminal cover , , , ( ) (21.5) ISOLATION INPUT-FG AC2 000V 1minute Cutoff current = 10mA DC500V 50MW min At Room Temperature 0.85 OUTPUT RC-FG *7 AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) - W Connector type Name plate 2-M3 , ( ), ( ) , ( , ) OPERATING TEMP. HUMID.AND ALTITUDE -10 to +71C Required Derating 20 - 90%RH Non condensing 3 000m 10 000feet max Mounting hole CN3 Option (Mfr : J.S.T.) STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75 , 20 - 90%RH (Non condensing) 9,000m (30,000feet) max C ENVIRONMENT Pin No. Contents 2 , ( ), , , VIBRATION 10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis 1 RC(+) 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis 2 RC(-) ( ) , ( ), , AGENCY APPROVALS At only AC input UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN SAFETY AND PBW50F NOISE CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS *10 HARMONIC ATTENUATOR Complies with IEC61000-3-2 Barrier strip type Tolerance : 1 0.04 CASE SIZE/WEIGHT 31 82 120mm 1.22 3.23 4.72 inches (without terminal block)(W H D) / 280g max (with cover : 325g max) X X X X X X OTHERS Weight : 280g max (with cover : 325g max) Model B2B-XH-A COOLING METHOD Convection 88 0.5 11 PCB Material/thickness : CEM3 / 1.6mm 0.06 Mating Connector (Terminal) 3.46 0.43 *1 Measured by 20MHz oscilloscope or Ripple-Noise *5 Figures for 0 to rated current 2.The current not measured *9 Please contact us about safety approvals for the model with Chassis material : Aluminum XHP-2 meter(equivalent to KEISOKU-GIKEN : RM101). side is fixed. option. Dimensions in mm, = inches BXH-001T-P0.6 *2 Drift is the change in DC output for an eight hour period *6 The sum of +power -power must be less than output power. *10Please contact us about class C. Mounting torque : 0.49N m(5kgf cm)max () or SXH-001T-P0.6 after a half-hour warm-up at 25C. *7 RC is applied to remote ON/OFF option. RC is isolated with * Parallel operation with other model is not possible. Screw tightening torque : M3 0.8N m(8.5kgf cm)max *3 Derating is required. input/output and FG. * Derating is required when operated with cover. Please connect safety ground to the unit in 2-M3 holes. *4 Figures for 0 to rated current 1.The current not measured *8 t5,t12,t15 can be used as +10,+24 and +30. * A sound may occur from power supply at peak loading. side is fixed. PBA/PBW-31 PBA/PBW-30 PBA/PBW-31 (71) 2.8 (12) 9.5 7.5 0.47 0.37 0.3 18 35 0.71 1.38 82 0.5 31 3.23 0.02 1.22 34.5 1.36