AC-DC Power Supplies Enclosed Type Medical Power World wide Safety EMI Inrush OCP OVP Remote Parallel 1U electric Factor Approvals current ON/OFF Operation equipment Correction limiting PCA-series PCA300F PCA600F PCA1000F PCA1500F Feature Up to 5-year warranty (Refer to Instruction Manual) Low profile (41mm, 1.61 inch = meet 1U height) CE marking Universal input 85 - 264VAC (Refer to Input vltage Derating) Low Voltage Directive DC input 88 - 370VDC possible : Excluding PCA1000F and RoHS Directive PCA1500F (Refer to Input vltage Derating) EMI For medical electric equipment - PCA300F, PCA600F (ANSI/AAMI ES60601-1, EN60601-1 3rd) Complies with FCC-B, CISPR32-B, EN55011-B, EN55032-B, Medical Isolation Grade 2MOPP VCCI-B With AUX output 12V 0.1A (Voltage adjustable range 5 - 12V) -PCA1000F , PCA1500F Constant current function Complies with FCC-A, CISPR32-A, EN55011-A, EN55032-A, Output voltage can be adjusted to near 0V (the item 2.6 on VCCI-A Instruction Manual) With various alarms EMS Compliance : EN61204-3, EN61000-6-2 Parallel Operation / N+1 Parallel Redundancy Operation possible IEC60601-1-2 (2014), EN60601-1-2 (2015) Monitoring function and various setting values can be changed EN61000-4-2 by communication (the item 2.11 on Instruction Manual) EN61000-4-3 EN61000-4-4 Safety agency approval EN61000-4-5 -UL62368-1, C-UL (CSA62368-1), EN62368-1, EN61000-4-6 ANSI/AAMI ES60601-1, EN60601-1 3rd EN61000-4-8 EN61000-4-11 April 02, 2021 PCA-1Ordering information AC-DC Power Supplies Enclosed Type PC A 300 F -5 -O PCA300F 1 2 3 4 5 6 1 Ser ies name Example recommended EMI/EMC filter R 2 Single output NAC-06-472 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *7 C : with Coating G : Low leakage current T : T erminal Block Style High voltage pulse noise type : NAP series I : with PMBus interface Low leakage current type : NAM series F2 : Reverse air exhaust type Low profile type : EAC series P3 : Master-slave Operation *A higher current r ating EMI/EMC filter W1 : Alar m function 2MOPP may be recommended in view of the other devices that could be connected in parallel with the power supply. For option details, refer to instruction manual 6.1. Terminal Block Style *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL PCA300F-5 PCA300F-12 PCA300F-15 PCA300F-24 PCA300F-32 PCA300F-48 MAX OUTPUT WATTAGE W 300 324 330 336 320 336 DC OUTPUT 5V 60A 12V 27A 15V 22A 24V 14A 32V 10A 48V 7A SPECIFICATIONS MODEL PCA300F-5 PCA300F-12 PCA300F-15 PCA300F-24 PCA300F-32 PCA300F-48 VAC 85 - 264 1f VOLTAGE *1 VDC 88 - 370 ACIN 100V 3.8typ CURRENT A ACIN 230V 1.6typ FREQUENCY Hz 50/60 (45 - 66) (Io=50%) 86typ 87typ 87typ 88typ 88typ 88typ ACIN 100V (Io=100%) 87typ 88typ 88typ 89typ 89typ 89typ INPUT EFFICIENCY % (Io=50%) 87typ 88typ 88typ 89typ 89typ 89typ ACIN 230V (Io=100%) 89typ 90typ 90typ 91typ 91typ 91typ ACIN 100V 0.98typ (Io=100%) POWER FACTOR ACIN 230V 0.95typ (Io=100%) *2 ACIN 100V 20/40 typ (Io=100%) (Primary inrush current / Secondary inrush current) (More than 3 sec. to re-start) INRUSH CURRENT A ACIN 230V *2 40/40 typ (Io=100%) (Primary inrush current / Secondary inrush current) (More than 3 sec. to re-start) LEAKAGE CURRENT mA 0.5max (ACIN 240V 60Hz, Io=100%, According to IEC60601-1) VOLTAGE V 5 12 15 24 32 48 CURRENT A 60 27 22 14 10 7 LINE REGULATION mV 20max 48max 60max 96max 128max 192max LOAD REGULATION mV 40max 100max 120max 150max 150max 480max *3*4 0 to +50C 160max 240max 240max 240max 320max 480max RIPPLE mVp-p *3 -20 to 0C 280max 320max 320max 320max 420max 640max *3*4 0 to +50C 240max 300max 300max 300max 400max 600max RIPPLE NOISE mVp-p OUTPUT -20 to 0C *3 320max 360max 360max 360max 480max 720max *4 0 to +50C 50max 120max 150max 240max 320max 480max TEMPERATURE REGULATION mV -20 to +50C *4 75max 180max 180max 290max 400max 600max *5 DRIFT mV 20max 48max 60max 96max 128max 192max START-UP TIME ms 700typ (ACIN 100/230V Io=100%) HOLD-UP TIME ms 20typ (ACIN 230V Io=80%) / 16typ (ACIN 230V Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 3.00 to 6.00 7.20 to 14.40 9.00 to 18.00 14.40 to 28.80 19.20 to 38.40 28.80 to 57.60 OUTPUT VOLTAGE SETTING V 5.00 to 5.05 12.00 to 12.12 15.00 to 15.15 24.00 to 24.24 32.00 to 32.32 48.00 to 48.48 OVERCURRENT PROTECTION Works over 105% of rating (Recovers automatically, Hiccup overcurrent) OVERVOLTAGE PROTECTION V 6.25 to 7.00 15.00 to 16.80 18.75 to 21.00 30.00 to 33.60 40.00 to 44.80 60.00 to 67.20 REMOTE SENSING Provided PROTECTION CIRCUIT AND REMOTE ON/OFF (RC) Provided OTHERS DC OK LAMP LED (Blue) ALARM LAMP LED (Orange) COMMUNICATION FUNCTION Provided (Extended UART) INPUT-OUTPUT AC4,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) 2MOPP INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M min (At Room Temperature) 1MOPP ISOLATION OUTPUT-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) OUTPUT - AUX-RC-PG-INFO-DS-ADDR0-ADDR1-ADDR2 AC500V 1minute, Cutoff current = 100mA, DC500V 50M min (At Room Temperature) OPERATING TEMP.,HUMIDITY.AND ALTITUDE -20 to +70C, 20 - 90%RH (Non condensing) STORAGE TEMP.,HUMIDITY.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) ENVIRONMENT 2 VIBRATION 10 - 55Hz 19.6m/s (2G) 3minutes period, 60minutes each along X, Y and Z axis 2 IMPACT 196.1m/s (20G) 11ms, once each X, Y and Z axis UL62368-1, EN62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), ANSI/AAMI ES60601-1, EN60601-1 3rd, AGENCY APPROVALS SAFETY C-UL (equivalent to CAN/CSA-C22.2 No.60601-1), Complies with IEC60601-1-2 4th Ed. AND NOISE CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR32-B, EN55011-B, EN55032-B REGULATIONS *6 HARMONIC ATTENUATOR Complies with IEC61000-3-2 (class A) April 02, 2021 PCA-2