AC-DC Power Supplies Enclosed Type Power Safety EMI OCP OVP World wide Cost Inrush Factor Approvals Effective current Correction limiting PJA-series Feature EMI Low Profile (PJA100F, 150F, 300F : 1U size) Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, (PJA600F, 1000F, 1500F : 2U size) VCCI-B Wide temperature range (-20C to +70C, Derating is required) (PJA1500F: Class A. In conducted noise, it can meet class B Harmonic attenuator (Complies with IEC61000-3-2 class A) by additional EMI/EMC filter.) Universal input (AC85 - 264V, Derating is required) Low power consumption at no load EMS Compliance : EN61204-3, EN61000-6-2 Complies with SEMI F-47 (PJA1000F, 1500F can meet at 200V EN61000-4-2 input range only) EN61000-4-3 Many optional functions EN61000-4-4 EN61000-4-5 Safety agency approvals EN61000-4-6 UL62368-1, C-UL (CSA62368-1), EN62368-1 EN61000-4-8 UL508 (PJA100F, 150F) EN61000-4-11 Complies with DEN-AN 5-year warranty (See Instruction Manual) CE marking Low Voltage Directive RoHS Directive June 25, 2020 PJA-1Ordering information AC-DC Power Supplies Enclosed Type PJ A 100 F -O -O PJA100F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R 2 Single output NAC-04-472 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 C : with Coating R : Remote on/off (Required external High voltage pulse noise type : NAP series power source) Low leakage current type : NAM series J : EP (Tyco Electronics) * A higher current rating EMI/EMC filter connector type may be recommended in view of the J1 : VH (J.S.T.) other devices that could be connected in parallel with the power supply. connector type T : Vertical terminal block N2 : with DIN rail See 6.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS * Please considerPBA100F-5- about 5V output with case cover. MODEL PJA100F-12 PJA100F-15 PJA100F-24 PJA100F-36 PJA100F-48 VOLTAGE V AC85 - 264 1f (Output derating is required at AC85V - 115V. Refer to Derating and instruction manual 1.1, 3) ACIN 100V 1.2typ (Io=90%) CURRENT A ACIN 115V 1.1typ (Io=100%) ACIN 230V 0.6typ (Io=100%) FREQUENCY Hz 50 / 60 (47 - 63) ACIN 100V 82typ (Io=90%) 83typ (Io=90%) 85typ (Io=90%) 86typ (Io=90%) 86typ (Io=90%) EFFICIENCY % ACIN 115V 82typ (Io=100%) 83typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) INPUT ACIN 230V 85typ (Io=100%) 86typ (Io=100%) 88typ (Io=100%) 89typ (Io=100%) 89typ (Io=100%) ACIN 100V 0.98typ (Io=90%) POWER FACTOR ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.90typ (Io=100%) * Power factor correction is stopped at AC250V or more. ACIN 100V 16typ (Io=90%) Ta=25C at cold start INRUSH CURRENT A ACIN 115V 16typ (Io=100%) Ta=25C at cold start ACIN 230V 32typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT mA 0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) VOLTAGE V 12 15 24 36 48 ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to Derating) CURRENT A ACIN 115V-264V 8.4 6.7 4.3 2.8 2.1 ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to Derating) WATTAGE W ACIN 115V-264V 100.8 100.5 103.2 100.8 100.8 *3 LINE REGULATION mV 48max 60max 96max 144max 192max LOAD REGULATION Io=30 to 100% 100max 120max 150max 150max 300max *3 mV Io=0 to 30% Burst operation (Please contact us about detail) 0 to +40C 120max 120max 120max 150max 150max RIPPLE mVp-p *1 -10 to 0C 160max 160max 160max 200max 400max Io: load factor OUTPUT Io=0 to 30% 500max 500max 500max 500max 500max 0 to +40C 150max 150max 150max 200max 200max RIPPLE NOISE mVp-p *1 -10 to 0C 180max 180max 180max 240max 500max Io: load factor Io=0 to 30% 600max 600max 600max 600max 600max 0 to +40C 120max 150max 240max 360max 480max TEMPERATURE REGULATION mV -10 to +40C 180max 180max 290max 440max 600max DRIFT mV *2 48max 60max 96max 144max 192max START-UP TIME ms 500typ (ACIN 115V, Io=100%) Ta=25C HOLD-UP TIME ms 20typ (ACIN 115V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 OUTPUT VOLTAGE SETTING V 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OVERVOLTAGE PROTECTION V 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20 PROTECTION CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Not provided REMOTE ON/OFF Optional (Required external power source. Option -R) *8 INPUT-OUTPUT RC AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) ISOLATION *8 OUTPUT RC-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) *8 OUTPUT-RC AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OPERATING TEMP.,HUMID.AND ALTITUDE *4 -20 to +70C (Refer to Derating), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axes AGENCY APPROVALS UL62368-1, C-UL (CSA62368-1), EN62368-1, UL508 (Except option -J, -J1) Complies with DEN-AN SAFETY AND NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS *7 HARMONIC ATTENUATOR Complies with IEC61000-3-2 class A June 25, 2020 PJA-2