Ordering information AC-DC Power Supplies Enclosed type PL A 300 F -O -O PLA PLA300F 1 2 3 4 5 6 1 Series name Recommended EMI/EMC Filter R 2 Single output NAC-06-472 3 Output wattage 4 Universal input 5 Output voltage *7 6 Optional C : with Coating G : Low leakage current V : External potentiometer for High voltage pulse noise type : NAP series output voltage adjustment Low leakage current type : NAM series U : Low input voltage stop * The EMI/EMC Filter is recommended (Complies with SEMI F-47) to connect with several devices. R : Remote on/off (Required external power source) F4: Low speed fan T2: Horizontal terminal block (non-screw-hold type) See 5.1 in Instruction Manual. SPECIFICATIONS MODEL PLA300F-5 PLA300F-12 PLA300F-15 PLA300F-24 PLA300F-36 PLA300F-48 *3 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) VOLTAGE V *3 (DC input and AC265 - 277V input ) ACIN 100V 3.1typ (Io=90%) 3.4typ (Io=90%) CURRENT A ACIN 115V 3.0typ (Io=100%) 3.3typ (Io=100%) ACIN 230V 1.5typ (Io=100%) 1.7typ (Io=100%) FREQUENCY Hz 50 / 60 (47 - 63) (DC input and 440Hz *3) ACIN 100V 73typ (Io=90%) 78typ (Io=90%) 80typ (Io=90%) 84typ (Io=90%) 84typ (Io=90%) 84typ (Io=90%) EFFICIENCY % ACIN 115V 74typ (Io=100%) 78typ (Io=100%) 80typ (Io=100%) 84typ (Io=100%) 84typ (Io=100%) 84typ (Io=100%) INPUT ACIN 230V 77typ (Io=100%) 81typ (Io=100%) 83typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) ACIN 100V 0.98typ (Io=90%) POWER FACTOR ACIN 115V 0.98typ (Io=100%) ACIN 230V 0.95typ (Io=100%) ACIN 100V 20typ (Io=90%) Ta=25C at cold start INRUSH CURRENT A ACIN 115V 20typ (Io=100%) Ta=25C at cold start ACIN 230V 40typ (Io=100%) Ta=25C at cold start LEAKAGE CURRENT mA 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) VOLTAGE V 5 1215243648 ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) CURRENT A ACIN 115V-264V 50 25 20 12.5 8.4 6.3 ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) WATTAGE W ACIN 115V-264V 250 300 300 300 302.4 302.4 LINE REGULATION mV *4 20max 48max 60max 96max 144max 192max *4 LOAD REGULATION mV 40max 100max 120max 150max 150max 300max 0 to +50C 80max 120max 120max 120max 150max 150max RIPPLE mVp-p *1 -10 to 0C 140max 160max 160max 160max 160max 400max OUTPUT 0 to +50C 120max 150max 150max 150max 200max 200max RIPPLE NOISE mVp-p *1 -10 to 0C 160max 180max 180max 180max 240max 500max 50max 120max 150max 240max 360max 480max 0 to +50C TEMPERATURE REGULATION mV -10 to +50C 75max 180max 180max 290max 440max 600max *2 DRIFT mV 20max 48max 60max 96max 144max 192max START-UP TIME ms 300typ (ACIN 115V, Io=100%) HOLD-UP TIME ms 20typ (ACIN 115V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 OUTPUT VOLTAGE SETTING V 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OVERVOLTAGE PROTECTION V 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 PROTECTION CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Not provided REMOTE ON/OFF Optional (Required external power source. Option -R) *10 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) INPUT-OUTPUT RC INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) ISOLATION *10 OUTPUT RC-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) OUTPUT-RC *10 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) *5 OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axes AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN SAFETY AND NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS HARMONIC ATTENUATOR *9 Complies with IEC61000-3-2 class A PLA-12 AC AC V.ADJ +V +V -V -V FG (N) (L) PLA300F PLA SPECIFICATIONS CASE SIZE/WEIGHT 102X41X190mm 4.02X1.61X7.48 inches (Excluding terminal block and screw) (WXHXD) / 1.0kg max OTHERS *8 Forced cooling (internal fan) COOLING METHOD WARRANTY WARRANTY *6 5 years (subject to the operating conditions) *1 This is the result of measurement of the testing board with capacitors of to be used for DC input, 440Hz input or AC265-277V input. isolated from input, output, and FG. 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 *4 Consult us about dynamic load and input response. * Do not use the power supply in overcurrent conditions or in unspeci ed MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken *5 Output power derating is required. See 3.2 in Instruction Manual. input voltage ranges. Otherwise the internal components may be RM103. *6 See 3.3 in Instruction Manual for more details. damaged. See 1.6 of Instruction Manual for more details. *7 Consult us about safety agency approvals for the models with optional functions. * Parallel operation is not possible with this mode. *2 Drift is the change in DC output for an eight hour period after a half-hour *8 The fan speed slows down at no load. * Sound noise may be heard from the power supply when used for warm-up at 25C. pulse load. *9 Consult us about other classes. *3 Output power derating is required. Consult us if the power supply needs *10 The RC terminal is added to option R models. The RC terminal is Features - Cost-effective - Longer life (see Instruction Manual) - Low profile (meets 1U height = 41 mm or 1.61 inches) - Wide operating temperature range (-20 to +70 see instruction manual) - Screw hold type terminal block - Slow fan speed at no load - Many optional functions - Complies with SEMI F-47 (-U option, see Instruction Manual for details) Block diagram FUSE 250V 10A INRUSH NOISE RECTIFIER AC IN 85 - 264V CURRENT FILTER LIMIT FG CURRENT CONTROL BOOSTER SENSING INDUCTOR RECTIFIER CURRENT AND SENSING CONTROL OVER VOLTAGE FILTER PROTECTION INVERTER RECTIFIER INVERTER AND DC OUT FILTER CONTROL THREE THERMAL TERMINAL FAN PROTECTION REGULATOR External view The external size of V option, R option, and T2 option models is different from the standard model. See 5. Options and Others in Instruction Manual for more details. 1.5 16.6 0.65 1.5 (LED) 13.42 0.53 1.5 (potentiometer) 13.1 0.52 4-M4 Mounting Hole LED Name plate 20max (Bottom side) 0.79max Output voltage adjustable potentiometer Output terminal (+) Output terminal () FG( ) AC(N) AC(L) M4 0.5 12.5 150 0.49 5.91 5max 190 Tolerance : 1 0.04 0.2max 7.48 Weight : 1.0kg max PCB Material/thickness : CEM-3 / 1.6mm 0.06inches Chassis material : Aluminum AIR FLOW Case material : Electric galvanizing steel board Dimensions in mm, =inches Mounting torque : 1.2N m max Screw tightening torque : 1.6N m max 0.5 19.5 150 Connect the input FG to safety earth ground. 0.77 5.91 4-M4 Mounting Hole PLA-13 1.5 8.6 5.75 0.23 0.34 12.51.5 0.49 19.8 1.5 0.78 10 5.7 0.39 0.22 0.5 0.5 10.5 25 19.5 60 0.41 0.98 0.77 2.36 102 41 1.61 4.02