Ordering information
AC-DC Power Supplies Medical Type
PM A 15 F -O -O
PMA15F
1 2 3 4 5 6
1 Series name
Example recommended EMI/EMC filter
R
2 Single output
NAM-04-000
3 Output wattage
4 Universal input
5 Output voltage
6 Optional *5
T : Vertical terminal block
T1 : Horizontal terminal block
N : with Cover
Low leakage current type : NAM series
J1 : VH(J.S.T.)connector type
* A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
Specification is changed at
option, refer to Instruction
Manual.
Horizontal terminal block Vertical terminal block Standard type with Cover
(option : -T1) (option : -T) (option : -N)
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
MODEL PMA15F-3R3 PMA15F-5 PMA15F-12 PMA15F-15 PMA15F-24
MAX OUTPUT WATTAGE[W] 9.9 15 15.6 15 16.8
DC OUTPUT 3.3V 3A 5V 3A 12V 1.3A 15V 1A 24V 0.7A
SPECIFICATIONS
MODEL PMA15F-3R3 PMA15F-5 PMA15F-12 PMA15F-15 PMA15F-24
VOLTAGE[V] AC85 - 264 1f (Refer to the Instruction Manual 1.1 and 3.2) *3
ACIN 100V 0.30typ (Io=100%) 0.40typ (Io=100%)
CURRENT[A]
ACIN 200V 0.15typ (Io=100%) 0.20typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 440)
INPUT ACIN 100V 66typ 70typ 74typ 76typ 76typ
EFFICIENCY[%]
ACIN 200V 67typ 74typ 78typ 79typ 79typ
ACIN 100V 15typ (Io=100%) (At cold start)
INRUSH CURRENT[A]
ACIN 200V 30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.05/0.10max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60601-1)
VOLTAGE[V] 3.3 5 12 15 24
CURRENT[A] 3.0 3.0 1.3 1.0 0.7
LINE REGULATION[mV] 20max 20max 48max 60max 96max
LOAD REGULATION[mV] 40max 40max 100max 120max 150max
0 to +50C
80max 80max 120max 120max 120max
RIPPLE[mVp-p]
*1
-10 - 0C 140max 140max 160max 160max 160max
0 to +50C 120max 120max 150max 150max 150max
RIPPLE NOISE[mVp-p]
*1
OUTPUT -10 - 0C 160max 160max 180max 180max 180max
0 to +50C 50max 50max 120max 150max 240max
TEMPERATURE REGULATION[mV]
-10 to +50C 60max 60max 150max 180max 290max
*2
DRIFT[mV] 20max 20max 48max 60max 96max
START-UP TIME[ms] 200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.60 4.50 to 5.50 10.00 to 13.20 13.20 to 18.00 19.20 to 27.00
OUTPUT VOLTAGE SETTING[V] 3.30 to 3.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION
OVERVOLTAGE PROTECTION[V] 4.00 to 5.25 5.75 to 7.00 15.00 to 18.00 20.00 to 25.00 30.00 to 37.00
CIRCUIT AND
OPERATING INDICATION LED (Green)
OTHERS
REMOTE ON/OFF Not provided
INPUT-OUTPUT AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max *3
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS UL60601-1, C-UL (CSA-C22.2 No.601.1), EN60601-1
SAFETY AND
NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B
REGULATIONS
*6
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter *4)
CASE SIZE/WEIGHT 31X78X103mm [1.22X3.07X4.06 inches] (WXHXD) / 230g max (with cover : 265g max)
OTHERS
COOLING METHOD Convection
*1 Measured b y 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN: RM101). *5 Please contact us about saf ety approvals for the model with option.
*2 Dr ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *6 Please contact us about another class.
*3 Derating is required. * Parallel operation with other model is not possible.
*4 When tw o or more units are used, they may not comply with the harmonic attenuator. Please * Der ating is required when operated with cover.
contact us for details. * A sound ma y occur from power supply at peak loading.
PMA-2PMA15F
Block diagram
FUSE
AC250V
2.5A INRUSH RECTIFIER
AC IN NOISE
CURRENT
AND
FILTER
85 264V
LIMIT FILTER
FG
TRANSFORMER
RECTIFIER
AND
CONTROL INVERTER DC OUT
FILTER
CURRENT
SENSING
Photocoupler
CONTROL
Photocoupler
OVER VOLTAGE
PROTECTION
External view
External size of option T,T1 and N is different from standard model and refer to 4 Option of instruction manual for detalis.
18 2.5
[0.71] [0.1] Point B:C503
1.5
Voltage Adjust LED 103
12.2
[4.06]
[0.48]
Cover name plate
Cover (Option)
CN2
4
+V
3
2
-V
1
5
FG
AC(L) 3
AC(N) 1
460.5 40.5
CN1
[1.81] [1.59]
Point A:C102
2-M3
Mounting Hole
Name plate 2-M3
Mounting Hole
750.5 8.5
Point A,Point B are thermometry points. Please refer to
[2.95] [0.33]
Instruction Manual 3.
I/O Connector Mating Connector Terminal
<PIN CONNECTION>
Chain 1123721-1
CN1 1-1123724-3 1-1123722-5
CN1 CN2
Tolerance : 1 [0.04]
Loose 1318912-1
Chain 1123721-1 Pin No. Input Pin No. Output Weight : 230g max (with cover : 265g max)
CN2 1-1123723-4 1-1123722-4
Loose 1318912-1
AC(N) PCB Material/thickness : CEM-3 / 1.6mm [0.06inches]
1
1, 2-V
Chassis material : Electric galvanizing steel board
(Mfr : Tyco Electronics AMP)
2
Keep drawing current per pin bellow 5A of CN2.
AC(L)
I/O Connector is Mfr.Tyco Electronics AMP 3
3, 4+V
Dimensions in mm, [ ]=inches
Option : -J1 : (J.S.T) connector type
4
Mounting torque : 0.6N m (6.3kgf cm) max
-T : Vertical terminal block type - -
5 FG
-T1 : Horizontal terminal block type Please connect safety ground to the unit in 2-M3 holes.
Refer to Instruction Manual 4.
PMA-3
70.5
[2.78]
18 36.5
[0.71]
[1.44]
78
31
[3.07]
[1.22]
34.5
[1.36]